Secondary Relining With Focal Flaring of Novel-Generation Balloon-Expandable Covered Stents for Endovascular Treatment of Significant Diameter Mismatch in the Aorto-Iliac Territory. (April 2021)
- Record Type:
- Journal Article
- Title:
- Secondary Relining With Focal Flaring of Novel-Generation Balloon-Expandable Covered Stents for Endovascular Treatment of Significant Diameter Mismatch in the Aorto-Iliac Territory. (April 2021)
- Main Title:
- Secondary Relining With Focal Flaring of Novel-Generation Balloon-Expandable Covered Stents for Endovascular Treatment of Significant Diameter Mismatch in the Aorto-Iliac Territory
- Authors:
- D'Oria, Mario
Griselli, Filippo
Mastrorilli, Davide
Gorgatti, Filippo
Bassini, Silvia
Riccitelli, Francesco
Calvagna, Cristiano
Zamolo, Francesca
Lepidi, Sandro - Abstract:
- Objectives: The aim of this study was to report on the safety and feasibility of secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory. Significant diameter mismatch was defined as >20% difference in the nominal diameter between the intended proximal and distal landing zones. Methods: Patient A was an 84-year-old man with prior abdominal aortic aneurysm open repair with a straight 20 mm Dacron tube. He presented with a right common iliac artery aneurysm (Ø88 mm) with contained rupture. The Gore Viabahn endoprosthesis (9 mm × 5 cm) was inserted proximally about 15 mm above the occluded ostium of the internal iliac artery. Subsequently, the BeGraft Aortic® (16 mm × 48 mm) was inserted proximally up to the common iliac artery origin; its proximal portion was flared to 22 mm. Patient B was a 77-year-old man with prior endovascular abdominal aortic aneurysm repair with a Medtronic Endurant stent-graft. He presented with occlusion of the right limb of the aortic endoprosthesis and thrombosis that extended down to the level of the superficial femoral artery. After mechanical thrombectomy, two Gore Viabahn endoprosthesis (first one, 8 mm × 10 cm; second one, 10 mm × 15 cm) were inserted into the right iliac limb. Subsequently, the BeGraft Aortic® (12mm × 39mm) was inserted proximally up to the gate of the aortic stent-graft; its proximal portion was flaredObjectives: The aim of this study was to report on the safety and feasibility of secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory. Significant diameter mismatch was defined as >20% difference in the nominal diameter between the intended proximal and distal landing zones. Methods: Patient A was an 84-year-old man with prior abdominal aortic aneurysm open repair with a straight 20 mm Dacron tube. He presented with a right common iliac artery aneurysm (Ø88 mm) with contained rupture. The Gore Viabahn endoprosthesis (9 mm × 5 cm) was inserted proximally about 15 mm above the occluded ostium of the internal iliac artery. Subsequently, the BeGraft Aortic® (16 mm × 48 mm) was inserted proximally up to the common iliac artery origin; its proximal portion was flared to 22 mm. Patient B was a 77-year-old man with prior endovascular abdominal aortic aneurysm repair with a Medtronic Endurant stent-graft. He presented with occlusion of the right limb of the aortic endoprosthesis and thrombosis that extended down to the level of the superficial femoral artery. After mechanical thrombectomy, two Gore Viabahn endoprosthesis (first one, 8 mm × 10 cm; second one, 10 mm × 15 cm) were inserted into the right iliac limb. Subsequently, the BeGraft Aortic® (12mm × 39mm) was inserted proximally up to the gate of the aortic stent-graft; its proximal portion was flared to 16 mm. Results: Technical success and clinical success were achieved in both patients. Imaging follow-up (6 months for Patient A, 12 months for Patient B) showed correct placement of all stent-grafts without any graft-related adverse event. The patients remained free from new reinterventions or recurrent symptoms. Patient A died 8 months after the index procedure from acute respiratory failure after community acquired pneumonia. Conclusion: Secondary relining with focal flaring of novel-generation balloon-expandable covered stents for endovascular treatment of significant diameter mismatch in the aorto-iliac territory is safe and feasible. Although mid-term results seem to be effective, longer follow-up is warranted to establish durability of the technique. … (more)
- Is Part Of:
- Vascular. Volume 29:Number 2(2021)
- Journal:
- Vascular
- Issue:
- Volume 29:Number 2(2021)
- Issue Display:
- Volume 29, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2021-0029-0002-0000
- Page Start:
- 207
- Page End:
- 212
- Publication Date:
- 2021-04
- Subjects:
- Secondary intervention -- stent-graft -- balloon-expandable covered stent -- aortoiliac disease
616.13 - Journal URLs:
- http://vascular.rsmjournals.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1708538120945056 ↗
- Languages:
- English
- ISSNs:
- 1708-5381
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15309.xml