Whether Pulmonary Valve Replacement in Asymptomatic Patients With Moderate or Severe Regurgitation After Tetralogy of Fallot Repair Is Appropriate: A Case‐Control Study. Issue 1 (8th January 2019)
- Record Type:
- Journal Article
- Title:
- Whether Pulmonary Valve Replacement in Asymptomatic Patients With Moderate or Severe Regurgitation After Tetralogy of Fallot Repair Is Appropriate: A Case‐Control Study. Issue 1 (8th January 2019)
- Main Title:
- Whether Pulmonary Valve Replacement in Asymptomatic Patients With Moderate or Severe Regurgitation After Tetralogy of Fallot Repair Is Appropriate: A Case‐Control Study
- Authors:
- He, Fengpu
Feng, Zicong
Chen, Qiuming
Jiao, Yiping
Hua, Zhongdong
Zhang, Hao
Yang, Keming
Pang, Kunjing
Lu, Minjie
Ma, Kai
Zhang, Sen
Qi, Lei
Wang, Guanxi
Li, Shoujun - Abstract:
- Abstract : Background: Although right ventricular (RV) volume was significantly decreased in symptomatic patients with repaired tetralogy of Fallot (rTOF) after pulmonary valve replacement (PVR), RV size was still enlarged along with RV dysfunction. Methods and Results: A prospective case‐control study was conducted in a tertiary hospital; 81 asymptomatic repaired tetralogy of Fallot patients with moderate or severe pulmonary regurgitation were enrolled. The enrolled cohort was divided into 2 groups: PVR group (n=41) and medication group (n=40). Cardiac magnetic resonance, transthoracic echocardiography, and electrocardiography were scheduled after recruitment and 6 months after PVR or recruitment. Adverse events were recorded during follow‐up. Three deaths, 1 heart transplantation, 3 PVRs, and 2 symptomatic heart failures in medication group and 1 redo PVR in the PVR group were observed during follow‐up. Compared with the medication group, the PVR group had significantly lower adverse events rate ( P =0.023; odds ratio, 0.086; 95% CI, 0.010–0.716), and RV function was significantly improved ( P <0.05). Binary logistic regression analysis identified preoperative RV end‐systolic volume index (10‐mL/m 2 increment, P =0.009; odds ratio, 0.64; 95% CI, 0.457–0.893) was an independent predictor of normalization of RV size after PVR. A preoperative RV end‐systolic volume index cut‐off value of 120 mL/m 2 (area under curve, 0.819; sensitivity, 90.3%; specificity, 70%) was analyzedAbstract : Background: Although right ventricular (RV) volume was significantly decreased in symptomatic patients with repaired tetralogy of Fallot (rTOF) after pulmonary valve replacement (PVR), RV size was still enlarged along with RV dysfunction. Methods and Results: A prospective case‐control study was conducted in a tertiary hospital; 81 asymptomatic repaired tetralogy of Fallot patients with moderate or severe pulmonary regurgitation were enrolled. The enrolled cohort was divided into 2 groups: PVR group (n=41) and medication group (n=40). Cardiac magnetic resonance, transthoracic echocardiography, and electrocardiography were scheduled after recruitment and 6 months after PVR or recruitment. Adverse events were recorded during follow‐up. Three deaths, 1 heart transplantation, 3 PVRs, and 2 symptomatic heart failures in medication group and 1 redo PVR in the PVR group were observed during follow‐up. Compared with the medication group, the PVR group had significantly lower adverse events rate ( P =0.023; odds ratio, 0.086; 95% CI, 0.010–0.716), and RV function was significantly improved ( P <0.05). Binary logistic regression analysis identified preoperative RV end‐systolic volume index (10‐mL/m 2 increment, P =0.009; odds ratio, 0.64; 95% CI, 0.457–0.893) was an independent predictor of normalization of RV size after PVR. A preoperative RV end‐systolic volume index cut‐off value of 120 mL/m 2 (area under curve, 0.819; sensitivity, 90.3%; specificity, 70%) was analyzed by receiver operating characteristic curves for normalized RV size after PVR. Conclusions: PVR in asymptomatic repaired tetralogy of Fallot patients is appropriate and effective in reducing right ventricular size and preserving right ventricular function. The recommended criterion of RV end‐systolic volume index for PVR is 120 mL/m 2 . … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 8:Issue 1(2019)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 8:Issue 1(2019)
- Issue Display:
- Volume 8, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2019-0008-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-01-08
- Subjects:
- asymptomatic -- magnetic resonance -- pulmonary valve -- tetralogy of Fallot
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.118.010689 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15280.xml