Portable, consumer‐grade pulse oximeters are accurate for home and medical use: Implications for use in the COVID‐19 pandemic and other resource‐limited environments. Issue 6 (20th October 2020)
- Record Type:
- Journal Article
- Title:
- Portable, consumer‐grade pulse oximeters are accurate for home and medical use: Implications for use in the COVID‐19 pandemic and other resource‐limited environments. Issue 6 (20th October 2020)
- Main Title:
- Portable, consumer‐grade pulse oximeters are accurate for home and medical use: Implications for use in the COVID‐19 pandemic and other resource‐limited environments
- Authors:
- Schrading, Walter A.
McCafferty, Ben
Grove, Jordan
Page, David B. - Abstract:
- Abstract: Objective: To determine the correlation between 3 lightweight portable pulse oximeter devices compared to a standard wall mount pulse oximetry device. Methods: We performed a single‐center, prospective, observational study of 4 pulse oximetry devices, 3 of which are commercially available to the public. A convenience sample of 200 emergency department (ED) patients with chief complaints of cardiopulmonary origin or a peripheral capillary oxygen saturation ≤ 94 percent were enrolled. Analysis of variance was performed to compare SpO2s and test characteristics of the 3 devices compared to control. Results: Although differences in measured SpO2s were observed ( P < 0.001) across groups, the differences were small (mean differences ranged from 1.00% to 1.87%). The correlation between test devices and the control were high (r range 0.70–0.79). Although the test characteristics were not perfect, the devices did have good sensitivity using a cutoff value of 94% (sensitivity ranging from 90% to 92%), which improved with lower SpO2 cutoff values to 92% (sensitivity ranging from 96% to 97%). Conclusion: The 3 commercially available devices were accurate enough to be clinically useful when compared to a hospital bedside monitor pulse oximeter. Consumer‐grade portable pulse oximeters may be useful if overwhelming numbers of patients require oxygen saturation monitoring, such as during the COVID‐19 pandemic.
- Is Part Of:
- JACEP open. Volume 1:Issue 6(2020)
- Journal:
- JACEP open
- Issue:
- Volume 1:Issue 6(2020)
- Issue Display:
- Volume 1, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 1
- Issue:
- 6
- Issue Sort Value:
- 2020-0001-0006-0000
- Page Start:
- 1450
- Page End:
- 1458
- Publication Date:
- 2020-10-20
- Subjects:
- COVID‐19/novel coronavirus -- hypoxia -- oxygen -- oxygenation status -- pulse oximetry -- respiratory physiological phenomena
Medical emergencies -- Periodicals
616.025 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
https://onlinelibrary.wiley.com/journal/26881152 ↗ - DOI:
- 10.1002/emp2.12292 ↗
- Languages:
- English
- ISSNs:
- 0361-1124
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15278.xml