Prognostic Significance of Pulse Pressure Variability During Mechanical Thrombectomy in Acute Ischemic Stroke Patients. Issue 18 (18th September 2018)
- Record Type:
- Journal Article
- Title:
- Prognostic Significance of Pulse Pressure Variability During Mechanical Thrombectomy in Acute Ischemic Stroke Patients. Issue 18 (18th September 2018)
- Main Title:
- Prognostic Significance of Pulse Pressure Variability During Mechanical Thrombectomy in Acute Ischemic Stroke Patients
- Authors:
- Maïer, Benjamin
Turc, Guillaume
Taylor, Guillaume
Blanc, Raphaël
Obadia, Michael
Smajda, Stanislas
Desilles, Jean‐Philippe
Redjem, Hocine
Ciccio, Gabriele
Boisseau, William
Sabben, Candice
Ben Machaa, Malek
Hamdani, Mylene
Leguen, Morgan
Gayat, Etienne
Blacher, Jacques
Lapergue, Bertrand
Piotin, Michel
Mazighi, Mikael - Other Names:
- Escalard Simon investigator.
Piotin Michel investigator.
Fahed Robert investigator.
Corabianu Ovide investigator.
de Broucker Thomas investigator.
Smadja Didier investigator.
Ille Olivier investigator.
Manchon Eric investigator.
Garcia Pierre‐Yves investigator.
Decroix J. P. investigator.
Wang A. investigator.
Wang A. investigator.
Evrard S. investigator.
Tchikviladzé M. investigator.
Bourdain F. investigator.
Coskun O. investigator.
Di Maria F. investigator.
Rodesch G. investigator.
Consoli A. investigator.
Tisserand M. investigator.
Pico F. investigator.
Rakotoharinandrasana H. investigator.
Tassan P. investigator.
Poll R. investigator.
Nighoghossian Norbert investigator.
Gory Benjamin investigator.
Riva Roberto investigator.
Eker O. investigator.
Derex Laurent investigator.
Cho Tae‐Hee investigator.
Mechtouff Laura investigator.
Lukaszewicz Anne‐Claire investigator.
Philippeau Frédéric investigator.
Cakmak Serkan investigator.
Blanc‐Lasserre Karine investigator.
Vallet Anne‐Evelyne investigator.
… (more) - Abstract:
- Abstract : Background: Studies on the role of blood pressure (BP) variability specifically during mechanical thrombectomy (MT) are sparse and limited. Moreover, pulse pressure (PP) has not been considered as a potent hemodynamic parameter to describe BP variability during MT. We assessed the impact of PP variability on functional outcome in acute ischemic stroke patients with large vessel occlusion during MT. Methods and Results: Acute ischemic stroke patients presenting with large vessel occlusion from January 2012 to June 2016 were included. BP data during MT were prospectively collected in the ETIS (Endovascular Treatment in Ischemic Stroke) registry. Logistic regression models were used to assess the association between PP coefficients of variation and functional outcome at 3 months (modified Rankin Scale). Among the 343 included patients, PP variability was significantly associated with worse 3‐month modified Rankin Scale in univariable (odds ratio [OR]=1.56, 95% confidence interval [CI]: 1.24–1.96 per 1‐unit increase, P =0.0002) and multivariable ordinal logistic regression (adjusted OR=1.40, 95% CI: 1.09–1.79, P =0.008). PP variability was also associated with unfavorable outcome (modified Rankin Scale 3–6) in univariable (OR=1.53, 95% CI: 1.17–2.01, P =0.002) and multivariable analysis (adjusted OR=1.42, 95% CI: 1.02–1.98, P =0.04). There was an association between PP variability and 3‐month all‐cause mortality in univariable analysis (OR= 1.37, 95% CI: 1.01–1.85 perAbstract : Background: Studies on the role of blood pressure (BP) variability specifically during mechanical thrombectomy (MT) are sparse and limited. Moreover, pulse pressure (PP) has not been considered as a potent hemodynamic parameter to describe BP variability during MT. We assessed the impact of PP variability on functional outcome in acute ischemic stroke patients with large vessel occlusion during MT. Methods and Results: Acute ischemic stroke patients presenting with large vessel occlusion from January 2012 to June 2016 were included. BP data during MT were prospectively collected in the ETIS (Endovascular Treatment in Ischemic Stroke) registry. Logistic regression models were used to assess the association between PP coefficients of variation and functional outcome at 3 months (modified Rankin Scale). Among the 343 included patients, PP variability was significantly associated with worse 3‐month modified Rankin Scale in univariable (odds ratio [OR]=1.56, 95% confidence interval [CI]: 1.24–1.96 per 1‐unit increase, P =0.0002) and multivariable ordinal logistic regression (adjusted OR=1.40, 95% CI: 1.09–1.79, P =0.008). PP variability was also associated with unfavorable outcome (modified Rankin Scale 3–6) in univariable (OR=1.53, 95% CI: 1.17–2.01, P =0.002) and multivariable analysis (adjusted OR=1.42, 95% CI: 1.02–1.98, P =0.04). There was an association between PP variability and 3‐month all‐cause mortality in univariable analysis (OR= 1.37, 95% CI: 1.01–1.85 per 1‐unit increase of the coefficient of variation of the PP, P =0.04), which did not remain significant after adjustment for potential confounders. Conclusions: PP variability during MT is an independent predictor of worse clinical outcome in acute ischemic stroke patients. These findings support the need for a close monitoring of BP variability during MT. Whether pharmacological interventions aiming at reducing BP variability during MT could impact functional outcome needs to be determined. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 7:Issue 18(2018)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 7:Issue 18(2018)
- Issue Display:
- Volume 7, Issue 18 (2018)
- Year:
- 2018
- Volume:
- 7
- Issue:
- 18
- Issue Sort Value:
- 2018-0007-0018-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-09-18
- Subjects:
- blood pressure -- blood pressure measurement/monitoring -- ischemic stroke -- pulse pressure -- thrombectomy
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.118.009378 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15282.xml