LUCAS Versus Manual Chest Compression During Ambulance Transport: A Hemodynamic Study in a Porcine Model of Cardiac Arrest. Issue 1 (8th January 2019)
- Record Type:
- Journal Article
- Title:
- LUCAS Versus Manual Chest Compression During Ambulance Transport: A Hemodynamic Study in a Porcine Model of Cardiac Arrest. Issue 1 (8th January 2019)
- Main Title:
- LUCAS Versus Manual Chest Compression During Ambulance Transport: A Hemodynamic Study in a Porcine Model of Cardiac Arrest
- Authors:
- Magliocca, Aurora
Olivari, Davide
De Giorgio, Daria
Zani, Davide
Manfredi, Martina
Boccardo, Antonio
Cucino, Alberto
Sala, Giulia
Babini, Giovanni
Ruggeri, Laura
Novelli, Deborah
Skrifvars, Markus B
Hardig, Bjarne Madsen
Pravettoni, Davide
Staszewsky, Lidia
Latini, Roberto
Belloli, Angelo
Ristagno, Giuseppe - Abstract:
- Abstract : Background: Mechanical chest compression (CC) is currently suggested to deliver sustained high‐quality CC in a moving ambulance. This study compared the hemodynamic support provided by a mechanical piston device or manual CC during ambulance transport in a porcine model of cardiopulmonary resuscitation. Methods and Results: In a simulated urban ambulance transport, 16 pigs in cardiac arrest were randomized to 18 minutes of mechanical CC with the LUCAS (n=8) or manual CC (n=8). ECG, arterial and right atrial pressure, together with end‐tidal CO2 and transthoracic impedance curve were continuously recorded. Arterial lactate was assessed during cardiopulmonary resuscitation and after resuscitation. During the initial 3 minutes of cardiopulmonary resuscitation, the ambulance was stationary, while then proceeded along a predefined itinerary. When the ambulance was stationary, CC‐generated hemodynamics were equivalent in the 2 groups. However, during ambulance transport, arterial and coronary perfusion pressure, and end‐tidal CO2 were significantly higher with mechanical CC compared with manual CC (coronary perfusion pressure: 43±4 versus 18±4 mmHg; end‐tidal CO2 : 31±2 versus 19±2 mmHg, P <0.01 at 18 minutes). During cardiopulmonary resuscitation, arterial lactate was lower with mechanical CC compared with manual CC (6.6±0.4 versus 8.2±0.5 mmol/L, P <0.01). During transport, mechanical CC showed greater constancy compared with the manual CC, as represented by a higherAbstract : Background: Mechanical chest compression (CC) is currently suggested to deliver sustained high‐quality CC in a moving ambulance. This study compared the hemodynamic support provided by a mechanical piston device or manual CC during ambulance transport in a porcine model of cardiopulmonary resuscitation. Methods and Results: In a simulated urban ambulance transport, 16 pigs in cardiac arrest were randomized to 18 minutes of mechanical CC with the LUCAS (n=8) or manual CC (n=8). ECG, arterial and right atrial pressure, together with end‐tidal CO2 and transthoracic impedance curve were continuously recorded. Arterial lactate was assessed during cardiopulmonary resuscitation and after resuscitation. During the initial 3 minutes of cardiopulmonary resuscitation, the ambulance was stationary, while then proceeded along a predefined itinerary. When the ambulance was stationary, CC‐generated hemodynamics were equivalent in the 2 groups. However, during ambulance transport, arterial and coronary perfusion pressure, and end‐tidal CO2 were significantly higher with mechanical CC compared with manual CC (coronary perfusion pressure: 43±4 versus 18±4 mmHg; end‐tidal CO2 : 31±2 versus 19±2 mmHg, P <0.01 at 18 minutes). During cardiopulmonary resuscitation, arterial lactate was lower with mechanical CC compared with manual CC (6.6±0.4 versus 8.2±0.5 mmol/L, P <0.01). During transport, mechanical CC showed greater constancy compared with the manual CC, as represented by a higher CC fraction and a lower transthoracic impedance curve variability ( P <0.01). All animals in the mechanical CC group and 6 (75%) in the manual one were successfully resuscitated. Conclusions: This model adds evidence in favor of the use of mechanical devices to provide ongoing high‐quality CC and tissue perfusion during ambulance transport. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 8:Issue 1(2019)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 8:Issue 1(2019)
- Issue Display:
- Volume 8, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2019-0008-0001-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-01-08
- Subjects:
- ambulance transport -- cardiac arrest -- cardiopulmonary resuscitation -- chest compression resuscitation -- manual cardiopulmonary resuscitation -- mechanical cardiopulmonary resuscitation
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.118.011189 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15280.xml