Long‐Term Comparison Between Pulmonary Homograft Versus Bioprosthesis for Pulmonary Valve Replacement in Tetralogy of Fallot. Issue 24 (17th December 2019)
- Record Type:
- Journal Article
- Title:
- Long‐Term Comparison Between Pulmonary Homograft Versus Bioprosthesis for Pulmonary Valve Replacement in Tetralogy of Fallot. Issue 24 (17th December 2019)
- Main Title:
- Long‐Term Comparison Between Pulmonary Homograft Versus Bioprosthesis for Pulmonary Valve Replacement in Tetralogy of Fallot
- Authors:
- Cocomello, Lucia
Meloni, Marco
Rapetto, Filippo
Baquedano, Mai
Ordoñez, Maria Victoria
Biglino, Giovanni
Bucciarelli‐Ducci, Chiara
Parry, Andrew
Stoica, Serban
Caputo, Massimo - Abstract:
- Abstract : Background: Tetralogy of Fallot repair results in late occurrence of pulmonary regurgitation, which requires pulmonary valve replacement in a large proportion of patients. Both homografts and bioprostheses are used for pulmonary valve replacement as uncertainty remains on which prosthesis should be considered superior. We performed a long‐term imaging and clinical comparison between these 2 strategies. Methods and Results: We compared echocardiographic and clinical follow‐up data of 209 patients with previous tetralogy of Fallot repair who underwent pulmonary valve replacement with homograft (n=75) or bioprosthesis (n=134) between 1995 and 2018 at a tertiary hospital. The primary end point was the composite of pulmonary valve replacement reintervention and structural valve deterioration, defined as a transpulmonary pressure decrease ≥50 mm Hg or pulmonary regurgitation degree of ≥2. Mixed linear model and Cox regression model were used for comparisons. Echocardiographic follow‐up duration was longer in the homograft group (8 [interquartile range, 4–12] versus 4 [interquartile range, 3–6] years; P <0.001). At the latest echocardiographic follow‐up, homografts showed a significantly lower transpulmonary systolic pressure decrease (16 [interquartile range, 12–25] mm Hg) when compared with bioprostheses (28 [interquartile range, 18–41] mm Hg; mixed model P <0.001) and a similar degree of pulmonary regurgitation (degree 0‐4) (1 [interquartile range, 0–2] versus 2Abstract : Background: Tetralogy of Fallot repair results in late occurrence of pulmonary regurgitation, which requires pulmonary valve replacement in a large proportion of patients. Both homografts and bioprostheses are used for pulmonary valve replacement as uncertainty remains on which prosthesis should be considered superior. We performed a long‐term imaging and clinical comparison between these 2 strategies. Methods and Results: We compared echocardiographic and clinical follow‐up data of 209 patients with previous tetralogy of Fallot repair who underwent pulmonary valve replacement with homograft (n=75) or bioprosthesis (n=134) between 1995 and 2018 at a tertiary hospital. The primary end point was the composite of pulmonary valve replacement reintervention and structural valve deterioration, defined as a transpulmonary pressure decrease ≥50 mm Hg or pulmonary regurgitation degree of ≥2. Mixed linear model and Cox regression model were used for comparisons. Echocardiographic follow‐up duration was longer in the homograft group (8 [interquartile range, 4–12] versus 4 [interquartile range, 3–6] years; P <0.001). At the latest echocardiographic follow‐up, homografts showed a significantly lower transpulmonary systolic pressure decrease (16 [interquartile range, 12–25] mm Hg) when compared with bioprostheses (28 [interquartile range, 18–41] mm Hg; mixed model P <0.001) and a similar degree of pulmonary regurgitation (degree 0‐4) (1 [interquartile range, 0–2] versus 2 [interquartile range, 0–2]; mixed model P =0.19). At 9 years, freedom from structural valve deterioration and reintervention was 81.6% (95% CI, 71.5%–91.6%) versus 43.4% (95% CI, 23.6%–63.2%) in the homograft and bioprosthesis groups, respectively (adjusted hazard ratio, 0.27; 95% CI, 0.13–0.55; P <0.001). Conclusions: When compared with bioprostheses, pulmonary homografts were associated lower transvalvular gradient during follow‐up and were associated with a significantly lower risk of reintervention or structural valve degeneration. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 8:Issue 24(2019)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 8:Issue 24(2019)
- Issue Display:
- Volume 8, Issue 24 (2019)
- Year:
- 2019
- Volume:
- 8
- Issue:
- 24
- Issue Sort Value:
- 2019-0008-0024-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-12-17
- Subjects:
- bioprosthesis -- homograft -- pulmonary heart disease -- regurgitation -- structural valve degeneration -- tetralogy of Fallot
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.119.013654 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15282.xml