Membrane‐hydration‐state detection in proton exchange membrane fuel cells using improved ambient‐condition‐based dynamic model. (8th November 2019)
- Record Type:
- Journal Article
- Title:
- Membrane‐hydration‐state detection in proton exchange membrane fuel cells using improved ambient‐condition‐based dynamic model. (8th November 2019)
- Main Title:
- Membrane‐hydration‐state detection in proton exchange membrane fuel cells using improved ambient‐condition‐based dynamic model
- Authors:
- Khan, Saad Saleem
Shareef, Hussain
Bouhaddioui, Chafik
Errouissi, Rachid - Abstract:
- Summary: Proton‐exchange‐membrane fuel cells (PEMFCs) are a popular source of alternative energy because of their operational reliability and compactness. This paper presents an improved model to represent the semi‐empirical voltage of PEMFCs to overcome the limitations of existing models. The proposed model considers variations in ambient conditions, such as the ambient temperature and relative humidity, to obtain the accurate output voltage that corresponds to variations in dynamic and static loads. The proposed model was developed by conducting several experiments on the Horizon PEMFC system under normal, humid, and dry ambient conditions. Subsequently, the model parameters corresponding to each case were optimised using the quantum lightning search algorithm (QLSA). Parameters demonstrating significant variations with ambient conditions were finally represented as a function of the ambient temperature and relative humidity via statistical regression analysis. The voltage obtained using the modified model was verified by conducting experiments on both the Horizon and NEXA PEMFC systems by varying the ambient temperature and relative humidity with root mean square error (RMSE) less than 0.5. As observed, the results we obtained using the modified model closely approximated those obtained using PEMFCs under various operating conditions, and in both cases, the PEMFC voltage was observed to vary with the ambient and load conditions. The inherent advantages of the proposedSummary: Proton‐exchange‐membrane fuel cells (PEMFCs) are a popular source of alternative energy because of their operational reliability and compactness. This paper presents an improved model to represent the semi‐empirical voltage of PEMFCs to overcome the limitations of existing models. The proposed model considers variations in ambient conditions, such as the ambient temperature and relative humidity, to obtain the accurate output voltage that corresponds to variations in dynamic and static loads. The proposed model was developed by conducting several experiments on the Horizon PEMFC system under normal, humid, and dry ambient conditions. Subsequently, the model parameters corresponding to each case were optimised using the quantum lightning search algorithm (QLSA). Parameters demonstrating significant variations with ambient conditions were finally represented as a function of the ambient temperature and relative humidity via statistical regression analysis. The voltage obtained using the modified model was verified by conducting experiments on both the Horizon and NEXA PEMFC systems by varying the ambient temperature and relative humidity with root mean square error (RMSE) less than 0.5. As observed, the results we obtained using the modified model closely approximated those obtained using PEMFCs under various operating conditions, and in both cases, the PEMFC voltage was observed to vary with the ambient and load conditions. The inherent advantages of the proposed PEMFC model include its ability to determine the membrane‐water content and water pressure inside PEMFCs. The membrane‐water content provides clear indications regarding the occurrence of drying and flooding faults. Under normal conditions, this membrane water content ranges from 11 to 7 for both the Horizon and NEXA PEMFC system. The simulation results suggested using the threshold membrane‐water‐content level as a possible indicator of fault occurrence under extreme ambient conditions. The limits of the said threshold were observed to be useful for fault diagnosis within PEMFC systems. … (more)
- Is Part Of:
- International journal of energy research. Volume 44:Number 2(2020)
- Journal:
- International journal of energy research
- Issue:
- Volume 44:Number 2(2020)
- Issue Display:
- Volume 44, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2020-0044-0002-0000
- Page Start:
- 869
- Page End:
- 889
- Publication Date:
- 2019-11-08
- Subjects:
- ambient conditions -- fault diagnostics -- membrane water content -- proton‐exchange‐membrane fuel cell (PEMFC) -- semi‐empirical modelling -- statistical analysis
Power resources -- Periodicals
Power (Mechanics) -- Periodicals
Power resources -- Research -- Periodicals
621.042 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/er.4927 ↗
- Languages:
- English
- ISSNs:
- 0363-907X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.236000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15287.xml