High-Sensitivity Cardiac Troponin T Concentrations below the Limit of Detection to Exclude Acute Myocardial Infarction: A Prospective Evaluation. (6th January 2020)
- Record Type:
- Journal Article
- Title:
- High-Sensitivity Cardiac Troponin T Concentrations below the Limit of Detection to Exclude Acute Myocardial Infarction: A Prospective Evaluation. (6th January 2020)
- Main Title:
- High-Sensitivity Cardiac Troponin T Concentrations below the Limit of Detection to Exclude Acute Myocardial Infarction: A Prospective Evaluation
- Authors:
- Body, Richard
Burrows, Gillian
Carley, Simon
Cullen, Louise
Than, Martin
Jaffe, Allan S
Lewis, Philip S - Abstract:
- Abstract: BACKGROUND: Initial reports suggest that concentrations of high-sensitivity cardiac troponin T (hs-cTnT) (Roche Diagnostics Elecsys ® ) below the limit of blank (LoB) (3 ng/L) or limit of detection (LoD) (5 ng/L) of the assay have almost 100% negative predictive value (NPV) for acute myocardial infarction (AMI), particularly among patients without electrocardiograph (ECG) evidence of ischemia. We aimed to prospectively validate those findings. METHODS: We included adults presenting to the emergency department with suspected cardiac chest pain. Standard troponin T (cTnT) and hs-cTnT (both Roche Elecsys) were tested in samples drawn on arrival. The primary outcome was AMI, adjudicated by 2 investigators on the basis of clinical data and ≥12-h cTnT testing. We also evaluated diagnostic performance when AMI was readjudicated on the basis of hs-cTnT (≥12-h) concentrations. RESULTS: Of 463 patients included, 79 (17.1%) had AMI. Twenty-four patients (5.2%) had hs-cTnT concentrations below the LoB, although none had AMI. Ninety-six patients (20.7%) had hs-cTnT concentrations below the LoD, 1 of whom had AMI. Thus, diagnostic sensitivity was 98.7% (95% CI 87.5%–98.6%) and NPV was 99.0% (95% CI 94.3%–100.0%). Of the 17.3% (n = 80) patients with hs-cTnT below the LoD and no ECG ischemia, none had AMI. Thus, diagnostic sensitivity was 100.0% (95% CI 95.4%–100.0%) and NPV was 100.0% (95% CI 95.5%–100.0%). Sensitivity and NPV were maintained when AMI was readjudicated on theAbstract: BACKGROUND: Initial reports suggest that concentrations of high-sensitivity cardiac troponin T (hs-cTnT) (Roche Diagnostics Elecsys ® ) below the limit of blank (LoB) (3 ng/L) or limit of detection (LoD) (5 ng/L) of the assay have almost 100% negative predictive value (NPV) for acute myocardial infarction (AMI), particularly among patients without electrocardiograph (ECG) evidence of ischemia. We aimed to prospectively validate those findings. METHODS: We included adults presenting to the emergency department with suspected cardiac chest pain. Standard troponin T (cTnT) and hs-cTnT (both Roche Elecsys) were tested in samples drawn on arrival. The primary outcome was AMI, adjudicated by 2 investigators on the basis of clinical data and ≥12-h cTnT testing. We also evaluated diagnostic performance when AMI was readjudicated on the basis of hs-cTnT (≥12-h) concentrations. RESULTS: Of 463 patients included, 79 (17.1%) had AMI. Twenty-four patients (5.2%) had hs-cTnT concentrations below the LoB, although none had AMI. Ninety-six patients (20.7%) had hs-cTnT concentrations below the LoD, 1 of whom had AMI. Thus, diagnostic sensitivity was 98.7% (95% CI 87.5%–98.6%) and NPV was 99.0% (95% CI 94.3%–100.0%). Of the 17.3% (n = 80) patients with hs-cTnT below the LoD and no ECG ischemia, none had AMI. Thus, diagnostic sensitivity was 100.0% (95% CI 95.4%–100.0%) and NPV was 100.0% (95% CI 95.5%–100.0%). Sensitivity and NPV were maintained when AMI was readjudicated on the basis of hs-cTnT. CONCLUSIONS: Our findings confirm that patients with nonischemic ECG and undetectable hs-cTnT at presentation have a very low probability of AMI, although the proportion of patients affected was smaller than in previous research. … (more)
- Is Part Of:
- Clinical chemistry. Volume 61:Number 7(2015)
- Journal:
- Clinical chemistry
- Issue:
- Volume 61:Number 7(2015)
- Issue Display:
- Volume 61, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 61
- Issue:
- 7
- Issue Sort Value:
- 2015-0061-0007-0000
- Page Start:
- 983
- Page End:
- 989
- Publication Date:
- 2020-01-06
- Subjects:
- Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1373/clinchem.2014.231530 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15287.xml