Monitoring IgA Multiple Myeloma: Immunoglobulin Heavy/Light Chain Assays. (6th January 2020)
- Record Type:
- Journal Article
- Title:
- Monitoring IgA Multiple Myeloma: Immunoglobulin Heavy/Light Chain Assays. (6th January 2020)
- Main Title:
- Monitoring IgA Multiple Myeloma: Immunoglobulin Heavy/Light Chain Assays
- Authors:
- Katzmann, Jerry A
Willrich, Maria A V
Kohlhagen, Mindy C
Kyle, Robert A
Murray, David L
Snyder, Melissa R
Rajkumar, S Vincent
Dispenzieri, Angela - Abstract:
- Abstract: BACKGROUND: The use of electrophoresis to monitor monoclonal immunoglobulins migrating in the β fraction may be difficult because of their comigration with transferrin and complement proteins. METHODS: Immunoassays specific for IgGκ, IgGλ, IgAκ, IgAλ, IgMκ, and IgMλ heavy/light chain (HLC) were validated for use in the clinical laboratory. We assessed sample stability, inter- and intraassay variability, linearity, accuracy, and reference intervals for all 6 assays. We tested accuracy by verifying that the sum of the concentrations for the HLC-pairs accounted for the total immunoglobulins in each of 129 healthy sera, and that the HLC-pair ratios (rHLCs) were outside the reference interval in 97% of 518 diagnostic multiple myeloma (MM) samples. RESULTS: We assessed diagnostic samples and posttreatment sera in 32 IgG and 30 IgA patients for HLC concentrations, rHLC, and total immunoglobulins and compared these nephelometry results with serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE). In sample sets from patients with IgG MM, the sensitivity of SPEP was almost the same as for rHLC, and no additional advantage was conferred by running HLC assays. In pre- and posttreatment samples from patients with IgA MM, the SPEP, rHLC, and IFE identified clonality in 28%, 56%, and 61%, respectively. In addition, when M-spikes were quantifiable, the concentration of the involved HLC was linearly related to that of the SPEP M-spike, with a slope near 1.Abstract: BACKGROUND: The use of electrophoresis to monitor monoclonal immunoglobulins migrating in the β fraction may be difficult because of their comigration with transferrin and complement proteins. METHODS: Immunoassays specific for IgGκ, IgGλ, IgAκ, IgAλ, IgMκ, and IgMλ heavy/light chain (HLC) were validated for use in the clinical laboratory. We assessed sample stability, inter- and intraassay variability, linearity, accuracy, and reference intervals for all 6 assays. We tested accuracy by verifying that the sum of the concentrations for the HLC-pairs accounted for the total immunoglobulins in each of 129 healthy sera, and that the HLC-pair ratios (rHLCs) were outside the reference interval in 97% of 518 diagnostic multiple myeloma (MM) samples. RESULTS: We assessed diagnostic samples and posttreatment sera in 32 IgG and 30 IgA patients for HLC concentrations, rHLC, and total immunoglobulins and compared these nephelometry results with serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE). In sample sets from patients with IgG MM, the sensitivity of SPEP was almost the same as for rHLC, and no additional advantage was conferred by running HLC assays. In pre- and posttreatment samples from patients with IgA MM, the SPEP, rHLC, and IFE identified clonality in 28%, 56%, and 61%, respectively. In addition, when M-spikes were quantifiable, the concentration of the involved HLC was linearly related to that of the SPEP M-spike, with a slope near 1. CONCLUSIONS: The use of IgA HLC assays for monitoring β-migrating IgA monoclonal proteins can substitute for the combination of SPEP, IFE, and total IgA quantification. … (more)
- Is Part Of:
- Clinical chemistry. Volume 61:Number 2(2015)
- Journal:
- Clinical chemistry
- Issue:
- Volume 61:Number 2(2015)
- Issue Display:
- Volume 61, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 61
- Issue:
- 2
- Issue Sort Value:
- 2015-0061-0002-0000
- Page Start:
- 360
- Page End:
- 367
- Publication Date:
- 2020-01-06
- Subjects:
- Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1373/clinchem.2014.231985 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15287.xml