Optimizing Early Rule-Out Strategies for Acute Myocardial Infarction: Utility of 1-Hour Copeptin. (6th January 2020)
- Record Type:
- Journal Article
- Title:
- Optimizing Early Rule-Out Strategies for Acute Myocardial Infarction: Utility of 1-Hour Copeptin. (6th January 2020)
- Main Title:
- Optimizing Early Rule-Out Strategies for Acute Myocardial Infarction: Utility of 1-Hour Copeptin
- Authors:
- Hillinger, Petra
Twerenbold, Raphael
Jaeger, Cedric
Wildi, Karin
Reichlin, Tobias
Gimenez, Maria Rubini
Engels, Ulrike
Miró, Oscar
Boeddinghaus, Jasper
Puelacher, Christian
Nestelberger, Thomas
Röthlisberger, Michèle
Ernst, Susanne
Rentsch, Katharina
Mueller, Christian - Abstract:
- Abstract: BACKGROUND: Combined testing of high-sensitivity cardiac troponin T (hs-cTnT) and copeptin at presentation provides a very high—although still imperfect—negative predictive value (NPV) for the early rule-out of acute myocardial infarction (AMI). We hypothesized that a second copeptin measurement at 1 h might further increase the NPV. METHODS: In a prospective diagnostic multicenter study, we measured hs-cTnT and copeptin concentrations at presentation and at 1 h in 1439 unselected patients presenting to the emergency department with suspected AMI. The final diagnosis was adjudicated by 2 independent cardiologists blinded to copeptin concentrations. We investigated the incremental value of 1-h copeptin in the rule-out setting (0-h hs-cTnT negative and 0-h copeptin negative) and the intermediate-risk setting (0-h hs-cTnT negative and 0-h copeptin positive). RESULTS: The adjudicated diagnosis was AMI in 267 patients (18.6%). For measurements obtained at presentation, the NPV in the rule-out setting was 98.6% (95% CI, 97.4%–99.3%). Whereas 1-h copeptin did not increase the NPV significantly, 1-h hs-cTnT did, to 99.6% (95% CI, 98.7%–99.9%, P = 0.008). Similarly, in the intermediate-risk setting (NPV 92.8%, 95% CI, 88.7%–95.8%), 1-h copeptin did not significantly increase the NPV ( P = 0.751), but 1-h hs-cTnT did, to 98.6 (95% CI, 96%–99.7%, P < 0.001). CONCLUSIONS: One-hour copeptin increased neither the safety of the rule-out process nor the NPV in theAbstract: BACKGROUND: Combined testing of high-sensitivity cardiac troponin T (hs-cTnT) and copeptin at presentation provides a very high—although still imperfect—negative predictive value (NPV) for the early rule-out of acute myocardial infarction (AMI). We hypothesized that a second copeptin measurement at 1 h might further increase the NPV. METHODS: In a prospective diagnostic multicenter study, we measured hs-cTnT and copeptin concentrations at presentation and at 1 h in 1439 unselected patients presenting to the emergency department with suspected AMI. The final diagnosis was adjudicated by 2 independent cardiologists blinded to copeptin concentrations. We investigated the incremental value of 1-h copeptin in the rule-out setting (0-h hs-cTnT negative and 0-h copeptin negative) and the intermediate-risk setting (0-h hs-cTnT negative and 0-h copeptin positive). RESULTS: The adjudicated diagnosis was AMI in 267 patients (18.6%). For measurements obtained at presentation, the NPV in the rule-out setting was 98.6% (95% CI, 97.4%–99.3%). Whereas 1-h copeptin did not increase the NPV significantly, 1-h hs-cTnT did, to 99.6% (95% CI, 98.7%–99.9%, P = 0.008). Similarly, in the intermediate-risk setting (NPV 92.8%, 95% CI, 88.7%–95.8%), 1-h copeptin did not significantly increase the NPV ( P = 0.751), but 1-h hs-cTnT did, to 98.6 (95% CI, 96%–99.7%, P < 0.001). CONCLUSIONS: One-hour copeptin increased neither the safety of the rule-out process nor the NPV in the intermediate-risk setting. In contrast, the incremental value of 1-h hs-cTnT was substantial in both settings. ClinicalTrials.gov/NCT00470587 … (more)
- Is Part Of:
- Clinical chemistry. Volume 61:Number 12(2015)
- Journal:
- Clinical chemistry
- Issue:
- Volume 61:Number 12(2015)
- Issue Display:
- Volume 61, Issue 12 (2015)
- Year:
- 2015
- Volume:
- 61
- Issue:
- 12
- Issue Sort Value:
- 2015-0061-0012-0000
- Page Start:
- 1466
- Page End:
- 1474
- Publication Date:
- 2020-01-06
- Subjects:
- Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1373/clinchem.2015.242743 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15274.xml