Subcutaneous Implantable Cardioverter‐Defibrillator in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy/Dysplasia: A Transatlantic Experience. Issue 21 (6th November 2018)
- Record Type:
- Journal Article
- Title:
- Subcutaneous Implantable Cardioverter‐Defibrillator in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy/Dysplasia: A Transatlantic Experience. Issue 21 (6th November 2018)
- Main Title:
- Subcutaneous Implantable Cardioverter‐Defibrillator in Patients With Arrhythmogenic Right Ventricular Cardiomyopathy/Dysplasia: A Transatlantic Experience
- Authors:
- Orgeron, Gabriela M.
Bhonsale, Aditya
Migliore, Federico
James, Cynthia A.
Tichnell, Crystal
Murray, Brittney
Bertaglia, Emanuele
Cadrin‐Tourigny, Julia
De Franceschi, Pietro
Crosson, Jane
Tandri, Harikrishna
Corrado, Domenico
Calkins, Hugh - Abstract:
- Abstract : Background: Despite growing use of the subcutaneous implantable cardioverter‐defibrillator (S‐ICD), its clinical role in arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) patients remains undefined. We aim to elucidate the cardiac phenotype, implant characteristics, and long‐term efficacy regarding appropriate therapy and complications in ARVC/D patients with an S‐ICD implant. Methods and Results: A transatlantic cohort of ARVC/D patients who underwent S‐ICD implantation was analyzed for clinical characteristics, S‐ICD therapy, and long‐term outcome including device‐related complications. The cohort included 29 patients (52% male, 76% probands, 59% with ARVC/D‐associated mutation, 59% primary prevention [no prior sustained ventricular arrhythmias], and 45% first‐generation S‐ICD devices). At implant, all inducible patients (27/29) had conversion of induced ventricular fibrillation. Two patients (7%) had superficial infections of the incision site that were treated conservatively. Over a median follow‐up of 3.16 years (interquartile range: 2.21–4.51 years), all episodes (6 patients, 4% per year) of sustained ventricular arrhythmias were appropriately detected and treated. Six patients (21%) experienced 39 inappropriate shocks, with 3 requiring device explantation. Oversensing of noncardiac signal (n=4; especially myopotentials) and cardiac signal (n=4) was the most frequent etiology. No lead or device dislodgement, infection, skin erosion, orAbstract : Background: Despite growing use of the subcutaneous implantable cardioverter‐defibrillator (S‐ICD), its clinical role in arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) patients remains undefined. We aim to elucidate the cardiac phenotype, implant characteristics, and long‐term efficacy regarding appropriate therapy and complications in ARVC/D patients with an S‐ICD implant. Methods and Results: A transatlantic cohort of ARVC/D patients who underwent S‐ICD implantation was analyzed for clinical characteristics, S‐ICD therapy, and long‐term outcome including device‐related complications. The cohort included 29 patients (52% male, 76% probands, 59% with ARVC/D‐associated mutation, 59% primary prevention [no prior sustained ventricular arrhythmias], and 45% first‐generation S‐ICD devices). At implant, all inducible patients (27/29) had conversion of induced ventricular fibrillation. Two patients (7%) had superficial infections of the incision site that were treated conservatively. Over a median follow‐up of 3.16 years (interquartile range: 2.21–4.51 years), all episodes (6 patients, 4% per year) of sustained ventricular arrhythmias were appropriately detected and treated. Six patients (21%) experienced 39 inappropriate shocks, with 3 requiring device explantation. Oversensing of noncardiac signal (n=4; especially myopotentials) and cardiac signal (n=4) was the most frequent etiology. No lead or device dislodgement, infection, skin erosion, or explantation related to need for antitachycardia pacing was noted. Conclusions: S‐ICD can effectively treat both induced and spontaneous ventricular arrhythmias in patients with ARVC/D. The rate of inappropriate shocks, although considerable, is comparable to that in ARVC/D patients treated with transvenous ICDs. When they occurred, inappropriate shocks were primarily due to cardiac and, uniquely, noncardiac oversensing. We suggest potential strategies for minimizing inappropriate therapy. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 7:Issue 21(2018)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 7:Issue 21(2018)
- Issue Display:
- Volume 7, Issue 21 (2018)
- Year:
- 2018
- Volume:
- 7
- Issue:
- 21
- Issue Sort Value:
- 2018-0007-0021-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-11-06
- Subjects:
- arrhythmogenic right ventricular cardiomyopathy -- implanted cardioverter defibrillator -- long‐term follow‐up -- ventricular tachycardia
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.118.008782 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15289.xml