Cerebral Protection During Catheter Ablation of Ventricular Tachycardia in Patients With Ischemic Heart Disease. Issue 13 (3rd July 2018)
- Record Type:
- Journal Article
- Title:
- Cerebral Protection During Catheter Ablation of Ventricular Tachycardia in Patients With Ischemic Heart Disease. Issue 13 (3rd July 2018)
- Main Title:
- Cerebral Protection During Catheter Ablation of Ventricular Tachycardia in Patients With Ischemic Heart Disease
- Authors:
- Heeger, Christian‐Hendrik
Metzner, Andreas
Schlüter, Michael
Rillig, Andreas
Mathew, Shibu
Tilz, Roland Richard
Wohlmuth, Peter
Romero, Maria E.
Virmani, Renu
Fink, Thomas
Reissmann, Bruno
Lemes, Christine
Maurer, Tilman
Santoro, Francesco
Schmidt, Tobias
Ghanem, Alexander
Frerker, Christian
Kuck, Karl‐Heinz
Ouyang, Feifan - Abstract:
- Abstract : Background: Catheter ablation of ventricular tachycardia (VT) is associated with the risk of cerebral embolism. The origin of periprocedural brain embolism in the setting of VT ablation is often unknown and strategies to avoid it are sparse. The aim of this study was to assess the safety and feasibility of an endovascular 2‐filter‐based cerebral protection system (CPS) in left ventricular VT ablation procedures in patients with ischemic heart disease. Furthermore, histopathological correlates of periprocedural embolization were investigated. Methods and Results: In this pilot study, 11 patients with ischemic heart disease and sustained VT underwent left ventricular catheter ablation under CPS surveillance. The placement of the CPS was conducted before the ablation procedure via the right radial artery. The VT ablation procedure was performed via a combined transaortic and transseptal approach. All VTs were successfully ablated. Placement and retrieval of the CPS was successful and safe in all cases. No periprocedural complications related to the CPS were observed and no periprocedural transient ischemic attack or stroke occurred. Debris captured by the CPS was detected in all patients. Histology revealed that acute thrombus was the most common type of debris (91%), followed by arterial wall tissue (73%) and foreign material (55%). Less frequently found were myocardium (27%), calcification (9%), necrotic core (9%), and valve tissue (9%). Conclusions: CerebralAbstract : Background: Catheter ablation of ventricular tachycardia (VT) is associated with the risk of cerebral embolism. The origin of periprocedural brain embolism in the setting of VT ablation is often unknown and strategies to avoid it are sparse. The aim of this study was to assess the safety and feasibility of an endovascular 2‐filter‐based cerebral protection system (CPS) in left ventricular VT ablation procedures in patients with ischemic heart disease. Furthermore, histopathological correlates of periprocedural embolization were investigated. Methods and Results: In this pilot study, 11 patients with ischemic heart disease and sustained VT underwent left ventricular catheter ablation under CPS surveillance. The placement of the CPS was conducted before the ablation procedure via the right radial artery. The VT ablation procedure was performed via a combined transaortic and transseptal approach. All VTs were successfully ablated. Placement and retrieval of the CPS was successful and safe in all cases. No periprocedural complications related to the CPS were observed and no periprocedural transient ischemic attack or stroke occurred. Debris captured by the CPS was detected in all patients. Histology revealed that acute thrombus was the most common type of debris (91%), followed by arterial wall tissue (73%) and foreign material (55%). Less frequently found were myocardium (27%), calcification (9%), necrotic core (9%), and valve tissue (9%). Conclusions: Cerebral protection during VT ablation seems to be safe and feasible. Ablation procedures of VT are associated with embolization of embolic debris, which was found in every patient. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 7:Issue 13(2018)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 7:Issue 13(2018)
- Issue Display:
- Volume 7, Issue 13 (2018)
- Year:
- 2018
- Volume:
- 7
- Issue:
- 13
- Issue Sort Value:
- 2018-0007-0013-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2018-07-03
- Subjects:
- catheter ablation -- histopathology -- stroke prevention -- ventricular tachycardia
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.118.009005 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15270.xml