Methyl-4-Hydroxybutyrate and Ethyl-4-Hydroxybutyrate as Potential Markers for Simultaneous Consumption of GHB/GBL and Alcohol: Preliminary Investigations. Issue 8 (11th August 2020)
- Record Type:
- Journal Article
- Title:
- Methyl-4-Hydroxybutyrate and Ethyl-4-Hydroxybutyrate as Potential Markers for Simultaneous Consumption of GHB/GBL and Alcohol: Preliminary Investigations. Issue 8 (11th August 2020)
- Main Title:
- Methyl-4-Hydroxybutyrate and Ethyl-4-Hydroxybutyrate as Potential Markers for Simultaneous Consumption of GHB/GBL and Alcohol: Preliminary Investigations
- Authors:
- Küting, Theresa
Beier, Niklas
Krämer, Michael
Madea, Burkhard - Abstract:
- Abstract: γ-Hydroxybutyric acid (GHB) and its corresponding lactone γ-butyrolactone (GBL) are misused as knock out (k.o.) drugs. The short detection window and the major inter- and intra-individual variations of endogenous GHB concentrations in commonly used matrices such as blood and urine complicate the analytical proof of an exogenous GHB/GBL administration. We searched for an alternative way to prove an exogenous GHB/GBL administration via detection of methyl- and ethyl-4-hydroxybutyrate, which could arise in alcoholic solutions after spiking with GHB/GBL. A liquid chromatographic–triple quadrupole mass spectrometric method was developed and validated to quantitatively determine methyl- and ethyl-4-hydroxybutyrate in alcoholic beverages (limit of detection [LoD]: 5.8 and 3.4 ng/mL, respectively). A sample collective of alcoholic beverages (n = 47) revealed natural occurring amounts of ethyl-4-hydroxybutyrate (<LoD—approx. 3980 ng/mL) with higher concentrations particularly found in wine samples. Nearly no ethyl-4-hydroxybutyrate was observable in spirits/liqueurs and no methyl-4-hydroxybutyrate was detectable at all. A moderate correlation was shown between the ethyl-4-hydroxybutyrate concentration and the pH-value in wine samples (pH 2.9–3.7, n = 29) as well as between the ethyl-4-hydroxybutyrate concentration and the GHB concentration in all measured beverages (GHB: < limit of quantification [LoQ]—11.4 µg/mL, n = 47). A dependency on alcohol content could not beAbstract: γ-Hydroxybutyric acid (GHB) and its corresponding lactone γ-butyrolactone (GBL) are misused as knock out (k.o.) drugs. The short detection window and the major inter- and intra-individual variations of endogenous GHB concentrations in commonly used matrices such as blood and urine complicate the analytical proof of an exogenous GHB/GBL administration. We searched for an alternative way to prove an exogenous GHB/GBL administration via detection of methyl- and ethyl-4-hydroxybutyrate, which could arise in alcoholic solutions after spiking with GHB/GBL. A liquid chromatographic–triple quadrupole mass spectrometric method was developed and validated to quantitatively determine methyl- and ethyl-4-hydroxybutyrate in alcoholic beverages (limit of detection [LoD]: 5.8 and 3.4 ng/mL, respectively). A sample collective of alcoholic beverages (n = 47) revealed natural occurring amounts of ethyl-4-hydroxybutyrate (<LoD—approx. 3980 ng/mL) with higher concentrations particularly found in wine samples. Nearly no ethyl-4-hydroxybutyrate was observable in spirits/liqueurs and no methyl-4-hydroxybutyrate was detectable at all. A moderate correlation was shown between the ethyl-4-hydroxybutyrate concentration and the pH-value in wine samples (pH 2.9–3.7, n = 29) as well as between the ethyl-4-hydroxybutyrate concentration and the GHB concentration in all measured beverages (GHB: < limit of quantification [LoQ]—11.4 µg/mL, n = 47). A dependency on alcohol content could not be observed. A voluntary intake (n = 1) of 750-mL wine naturally containing high amounts of ethyl-4-hydroxybutyrate (approx. 2010 ng/mL) revealed no observable GHB-ester concentrations in blood and urine. Furthermore, an experiment simulating a beverage that could potentially be used in a drug-facilitated crime (DFC) case showed ethyl-4-hydroxybutyrate concentrations exceeding the concentrations naturally observed in beverage samples. However, in order to evaluate whether ethyl-4-hydroxybutyrate could be useful as marker for the co-consumption of GHB/GBL and alcohol and to prolong the detection window of unintended GHB/GBL intake, further experiments have to be performed. … (more)
- Is Part Of:
- Journal of analytical toxicology. Volume 44:Issue 8(2020)
- Journal:
- Journal of analytical toxicology
- Issue:
- Volume 44:Issue 8(2020)
- Issue Display:
- Volume 44, Issue 8 (2020)
- Year:
- 2020
- Volume:
- 44
- Issue:
- 8
- Issue Sort Value:
- 2020-0044-0008-0000
- Page Start:
- 818
- Page End:
- 828
- Publication Date:
- 2020-08-11
- Subjects:
- Drugs -- Analysis -- Periodicals
Drugs -- Toxicity testing -- Periodicals
615.907 - Journal URLs:
- http://jat.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/jat/bkaa096 ↗
- Languages:
- English
- ISSNs:
- 0146-4760
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.700000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15242.xml