Association between SARS-CoV-2 Neutralizing Antibodies and Commercial Serological Assays. (7th October 2020)
- Record Type:
- Journal Article
- Title:
- Association between SARS-CoV-2 Neutralizing Antibodies and Commercial Serological Assays. (7th October 2020)
- Main Title:
- Association between SARS-CoV-2 Neutralizing Antibodies and Commercial Serological Assays
- Authors:
- Tang, Mei San
Case, James Brett
Franks, Caroline E
Chen, Rita E
Anderson, Neil W
Henderson, Jeffrey P
Diamond, Michael S
Gronowski, Ann M
Farnsworth, Christopher W - Abstract:
- Abstract: Background: Commercially available SARS-CoV-2 serological assays based on different viral antigens have been approved for the qualitative determination of anti-SARS-CoV-2 antibodies. However, there are limited published data associating the results from commercial assays with neutralizing antibodies. Methods: Sixty-six specimens from 48 patients with PCR-confirmed COVID-19 and a positive result by the Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, or EUROIMMUN SARS-CoV-2 IgG assays and 5 control specimens were analyzed for the presence of neutralizing antibodies to SARS-CoV-2. Correlation, concordance, positive percent agreement (PPA), and negative percent agreement (NPA) were calculated at several cutoffs. Results were compared in patients categorized by clinical outcomes. Results: The correlation between SARS-CoV-2 neutralizing titer (EC50 ) and the Roche, Abbott, and EUROIMMUN assays was 0.29, 0.47, and 0.46, respectively. At an EC50 of 1:32, the concordance kappa with Roche was 0.49 (95% CI; 0.23–0.75), with Abbott was 0.52 (0.28–0.77), and with EUROIMMUN was 0.61 (0.4–0.82). At the same neutralizing titer, the PPA and NPA for the Roche was 100% (94–100) and 56% (30–80); Abbott was 96% (88–99) and 69% (44–86); and EUROIMMUN was 91% (80–96) and 81% (57–93) for distinguishing neutralizing antibodies. Patients who were intubated, had cardiac injury, or acute kidney injury from COVID-19 infection had higher neutralizing titers relative to those with mildAbstract: Background: Commercially available SARS-CoV-2 serological assays based on different viral antigens have been approved for the qualitative determination of anti-SARS-CoV-2 antibodies. However, there are limited published data associating the results from commercial assays with neutralizing antibodies. Methods: Sixty-six specimens from 48 patients with PCR-confirmed COVID-19 and a positive result by the Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, or EUROIMMUN SARS-CoV-2 IgG assays and 5 control specimens were analyzed for the presence of neutralizing antibodies to SARS-CoV-2. Correlation, concordance, positive percent agreement (PPA), and negative percent agreement (NPA) were calculated at several cutoffs. Results were compared in patients categorized by clinical outcomes. Results: The correlation between SARS-CoV-2 neutralizing titer (EC50 ) and the Roche, Abbott, and EUROIMMUN assays was 0.29, 0.47, and 0.46, respectively. At an EC50 of 1:32, the concordance kappa with Roche was 0.49 (95% CI; 0.23–0.75), with Abbott was 0.52 (0.28–0.77), and with EUROIMMUN was 0.61 (0.4–0.82). At the same neutralizing titer, the PPA and NPA for the Roche was 100% (94–100) and 56% (30–80); Abbott was 96% (88–99) and 69% (44–86); and EUROIMMUN was 91% (80–96) and 81% (57–93) for distinguishing neutralizing antibodies. Patients who were intubated, had cardiac injury, or acute kidney injury from COVID-19 infection had higher neutralizing titers relative to those with mild symptoms. Conclusions: COVID-19 patients generate an antibody response to multiple viral proteins such that the calibrator ratios on the Roche, Abbott, and EUROIMMUN assays are all associated with SARS-CoV-2 neutralization. Nevertheless, commercial serological assays have poor NPA for SARS-CoV-2 neutralization, making them imperfect proxies for neutralization. … (more)
- Is Part Of:
- Clinical chemistry. Volume 66:Number 12(2020)
- Journal:
- Clinical chemistry
- Issue:
- Volume 66:Number 12(2020)
- Issue Display:
- Volume 66, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 66
- Issue:
- 12
- Issue Sort Value:
- 2020-0066-0012-0000
- Page Start:
- 1538
- Page End:
- 1547
- Publication Date:
- 2020-10-07
- Subjects:
- Serology -- neutralizing antibodies -- COVID-19 -- SARS-CoV-2
Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1093/clinchem/hvaa211 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15237.xml