Impact of combined baseline and postprocedural troponin values on clinical outcome following the MitraClip procedure. Issue 7 (25th March 2020)
- Record Type:
- Journal Article
- Title:
- Impact of combined baseline and postprocedural troponin values on clinical outcome following the MitraClip procedure. Issue 7 (25th March 2020)
- Main Title:
- Impact of combined baseline and postprocedural troponin values on clinical outcome following the MitraClip procedure
- Authors:
- Tabata, Noriaki
Weber, Marcel
Sugiura, Atsushi
Ishii, Masanobu
Öztürk, Can
Tsujita, Kenichi
Sinning, Jan‐Malte
Werner, Nikos
Nickenig, Georg - Abstract:
- Abstract: Objectives: The purpose of this study was to investigate the impact of periprocedural troponin levels on clinical outcome following the MitraClip procedure. Background: Cardiac troponin is known to be a predictive biomarker for various clinical outcomes; however, data about its predictive value in patients undergoing transcatheter mitral valve repair are limited. Methods: Consecutive patients undergoing the MitraClip procedure were enrolled. Serum cardiac troponin I concentrations were measured before and after the procedure, and the maximal value recorded within 72 hr after the procedure was used for the postprocedural values. The clinical outcome was all‐cause mortality within a 1‐year follow‐up. Results: Out of 354 patients, 29 patients (8.2%) were deceased within 1 year. Patients who died had significantly higher baseline (0.05 [0.01–0.08] vs. 0.01 [0.01–0.03] ng/ml; p < .001) and postprocedural troponin I values (0.51 [0.30–1.42] vs. 0.20 [0.33–0.55] ng/ml; p = .005). A Kaplan–Meier analysis showed that patients with higher baseline troponin I values had a significantly worse prognosis than those with lower values (log‐rank p < .001), and similarly, 1‐year mortality was significantly higher in patients with higher postprocedural troponin I than those with lower levels (log‐rank p = .021). Moreover, the highest mortality rate was observed in patients with both elevated baseline and postprocedural troponin I values (log‐rank p = .001), which was found to be anAbstract: Objectives: The purpose of this study was to investigate the impact of periprocedural troponin levels on clinical outcome following the MitraClip procedure. Background: Cardiac troponin is known to be a predictive biomarker for various clinical outcomes; however, data about its predictive value in patients undergoing transcatheter mitral valve repair are limited. Methods: Consecutive patients undergoing the MitraClip procedure were enrolled. Serum cardiac troponin I concentrations were measured before and after the procedure, and the maximal value recorded within 72 hr after the procedure was used for the postprocedural values. The clinical outcome was all‐cause mortality within a 1‐year follow‐up. Results: Out of 354 patients, 29 patients (8.2%) were deceased within 1 year. Patients who died had significantly higher baseline (0.05 [0.01–0.08] vs. 0.01 [0.01–0.03] ng/ml; p < .001) and postprocedural troponin I values (0.51 [0.30–1.42] vs. 0.20 [0.33–0.55] ng/ml; p = .005). A Kaplan–Meier analysis showed that patients with higher baseline troponin I values had a significantly worse prognosis than those with lower values (log‐rank p < .001), and similarly, 1‐year mortality was significantly higher in patients with higher postprocedural troponin I than those with lower levels (log‐rank p = .021). Moreover, the highest mortality rate was observed in patients with both elevated baseline and postprocedural troponin I values (log‐rank p = .001), which was found to be an independent predictor of mortality by multivariable analyses. Conclusions: The present study suggests that combined baseline and postprocedural troponin measurements are useful for risk stratification of 1‐year mortality following the MitraClip procedure. … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 96:Issue 7(2020)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 96:Issue 7(2020)
- Issue Display:
- Volume 96, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 96
- Issue:
- 7
- Issue Sort Value:
- 2020-0096-0007-0000
- Page Start:
- E735
- Page End:
- E743
- Publication Date:
- 2020-03-25
- Subjects:
- biomarkers -- mitral valve disease -- percutaneous intervention
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.28869 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15231.xml