Balloon catheter for induction of labor in women with one previous cesarean and an unfavorable cervix. (7th March 2019)
- Record Type:
- Journal Article
- Title:
- Balloon catheter for induction of labor in women with one previous cesarean and an unfavorable cervix. (7th March 2019)
- Main Title:
- Balloon catheter for induction of labor in women with one previous cesarean and an unfavorable cervix
- Authors:
- Huisman, Claartje M. A.
ten Eikelder, Mieke L. G.
Mast, Kelly
Oude Rengerink, Katrien
Jozwiak, Marta
van Dunné, Frédérique
Duvekot, Johannes J.
van Eyck, Jim
Gaugler‐Senden, Ingrid
de Groot, Christianne J. M.
Franssen, Maureen T. M.
van Gemund, Nicolette
Langenveld, Josje
de Leeuw, Jan Willem
Oude Lohuis, Eefje J.
Oudijk, Martijn A.
Papatsonis, Dimitri
van Pampus, Mariëlle
Porath, Martina
Rombout‐de Weerd, Sabina
van Roosmalen, Jos J.
van der Salm, Paulien C. M.
Scheepers, Hubertina C. J.
Sikkema, Marko J.
Sporken, Jan
Stigter, Rob H.
van Wijngaarden, Wim J.
Woiski, Mallory
Mol, Ben Willem J.
Bloemenkamp, Kitty W. M. - Abstract:
- Abstract: Introduction: When women with a previous cesarean section and an unfavorable cervix have an indication for delivery, the choice is to induce labor or to perform a cesarean section. This study aims to assess the effectiveness and safety of a balloon catheter as a method of induction of labor in women with one previous cesarean section and an unfavorable cervix compared with an elective repeat cesarean section. Material and methods: We performed a prospective cohort study in 51 hospitals in the Netherlands on term women with one previous cesarean section, a live singleton fetus in cephalic position, an unfavorable cervix and an indication for delivery. We recorded obstetric, maternal and neonatal characteristics. We compared the outcome of women who were induced with a balloon catheter with the outcome of women who delivered by elective repeat cesarean section. Main outcomes were maternal and neonatal morbidity. Mode of delivery was a secondary outcome for women who were induced. Adjusted odds ratios (aOR) were calculated using logistic regression, adjusted for potential confounders. Results: Analysis was performed on 993 women who were induced and 321 women who had a repeat cesarean section (August 2011 until September 2012). Among the women who were induced, 560 (56.4%) delivered vaginally and 11 (1.1%) sustained a uterine rupture. Composite adverse maternal outcome (uterine rupture, severe postpartum hemorrhage or postpartum infection) occurred in 73 (7.4%) in theAbstract: Introduction: When women with a previous cesarean section and an unfavorable cervix have an indication for delivery, the choice is to induce labor or to perform a cesarean section. This study aims to assess the effectiveness and safety of a balloon catheter as a method of induction of labor in women with one previous cesarean section and an unfavorable cervix compared with an elective repeat cesarean section. Material and methods: We performed a prospective cohort study in 51 hospitals in the Netherlands on term women with one previous cesarean section, a live singleton fetus in cephalic position, an unfavorable cervix and an indication for delivery. We recorded obstetric, maternal and neonatal characteristics. We compared the outcome of women who were induced with a balloon catheter with the outcome of women who delivered by elective repeat cesarean section. Main outcomes were maternal and neonatal morbidity. Mode of delivery was a secondary outcome for women who were induced. Adjusted odds ratios (aOR) were calculated using logistic regression, adjusted for potential confounders. Results: Analysis was performed on 993 women who were induced and 321 women who had a repeat cesarean section (August 2011 until September 2012). Among the women who were induced, 560 (56.4%) delivered vaginally and 11 (1.1%) sustained a uterine rupture. Composite adverse maternal outcome (uterine rupture, severe postpartum hemorrhage or postpartum infection) occurred in 73 (7.4%) in the balloon and 14 (4.5%) women in the repeat cesarean section group (aOR 1.58, 95% confidence interval [CI] 0.85‐2.96). Composite adverse neonatal outcome (Apgar score <7 at 5 minutes or umbilical pH <7.10) occurred in 57 (5.7%) and 10 (3.2%) neonates, respectively (aOR 1.40, 95% CI 0.87‐3.48). Women who were induced had a shorter postpartum admission time (2.0 vs 3.0 days ( P < 0.0001)). Conclusions: In women with a previous cesarean section and a need for delivery, induction of labor with a balloon catheter does not result in a significant increase in adverse maternal and neonatal outcomes as compared with planned cesarean section. … (more)
- Is Part Of:
- Acta obstetricia et gynecologica Scandinavica. Volume 98:Number 7(2019)
- Journal:
- Acta obstetricia et gynecologica Scandinavica
- Issue:
- Volume 98:Number 7(2019)
- Issue Display:
- Volume 98, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 98
- Issue:
- 7
- Issue Sort Value:
- 2019-0098-0007-0000
- Page Start:
- 920
- Page End:
- 928
- Publication Date:
- 2019-03-07
- Subjects:
- balloon catheter -- cervical ripening -- induction of labor -- repeat cesarean -- vaginal birth after cesarean
Gynecology -- Periodicals
Pregnancy -- Periodicals
Obstetrics -- Periodicals
618.05 - Journal URLs:
- http://informahealthcare.com/loi/obs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://www.tandf.co.uk/journals/titles/00016349.asp ↗ - DOI:
- 10.1111/aogs.13558 ↗
- Languages:
- English
- ISSNs:
- 0001-6349
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0641.600000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15231.xml