Riata lead failure in pediatric and congenital heart disease patients. (4th January 2019)
- Record Type:
- Journal Article
- Title:
- Riata lead failure in pediatric and congenital heart disease patients. (4th January 2019)
- Main Title:
- Riata lead failure in pediatric and congenital heart disease patients
- Authors:
- Escudero, Carolina A.
Mah, Douglas Y.
Miyake, Christina Y.
Stephenson, Elizabeth A.
LaPage, Martin J.
Kubuš, Peter
I. Cohen, Mitchell
Atallah, Joseph - Abstract:
- Abstract: Background: Implantable cardioverter defibrillator (ICD) lead failures occur at higher rates in pediatric and congenital heart disease (CHD) patients. Objective: To determine the rate and timing of Riata lead failure in pediatric and CHD patients. Methods: This was a retrospective, multicenter cohort study of pediatric patients and adults with CHD with implantation of a Riata or Riata ST lead between 2002 and 2009. The prevalence and timing of electrical failure and conductor coil externalization (CCE) were determined. Results: Fifty‐eight patients and 63 leads from seven centers were included. Median (interquartile range [IQR]) age at implant was 14.4 (11.5‐18.7) years and median follow‐up was 8.7 (7.3‐11.1) years. The underlying diagnosis was a primary arrhythmia disorder in 45%, cardiomyopathy in 31%, and CHD in 28% of patients. Electrical failure occurred in 43% and CCE in 16% of leads at median lead ages of 4.7 (3.4‐7.5) and 4.3 (3.9‐7.0) years, respectively. Median lead survival free from electrical failure or CCE was 7.9 (95% confidence interval, 5.8‐10.0) years. Forty‐one percent of leads were functional at the end of the follow‐up period, and 33% were extracted with a complication rate of 5%. Conclusions: The rate of Riata lead electrical failure was high in children and patients with CHD, while the rate of CCE was comparable with published data. Counseling on lead management should factor in the high rate of electrical failure with considerations forAbstract: Background: Implantable cardioverter defibrillator (ICD) lead failures occur at higher rates in pediatric and congenital heart disease (CHD) patients. Objective: To determine the rate and timing of Riata lead failure in pediatric and CHD patients. Methods: This was a retrospective, multicenter cohort study of pediatric patients and adults with CHD with implantation of a Riata or Riata ST lead between 2002 and 2009. The prevalence and timing of electrical failure and conductor coil externalization (CCE) were determined. Results: Fifty‐eight patients and 63 leads from seven centers were included. Median (interquartile range [IQR]) age at implant was 14.4 (11.5‐18.7) years and median follow‐up was 8.7 (7.3‐11.1) years. The underlying diagnosis was a primary arrhythmia disorder in 45%, cardiomyopathy in 31%, and CHD in 28% of patients. Electrical failure occurred in 43% and CCE in 16% of leads at median lead ages of 4.7 (3.4‐7.5) and 4.3 (3.9‐7.0) years, respectively. Median lead survival free from electrical failure or CCE was 7.9 (95% confidence interval, 5.8‐10.0) years. Forty‐one percent of leads were functional at the end of the follow‐up period, and 33% were extracted with a complication rate of 5%. Conclusions: The rate of Riata lead electrical failure was high in children and patients with CHD, while the rate of CCE was comparable with published data. Counseling on lead management should factor in the high rate of electrical failure with considerations for elective replacement. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 3(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 3(2019)
- Issue Display:
- Volume 30, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 3
- Issue Sort Value:
- 2019-0030-0003-0000
- Page Start:
- 320
- Page End:
- 325
- Publication Date:
- 2019-01-04
- Subjects:
- children -- congenital heart disease -- lead failure -- Pediatric and Congenital Electrophysiology Society (PACES) -- pediatric -- Riata lead
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.13812 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15229.xml