Clinical significance of superior articular process as a reference point for free-hand pedicle screw insertion in thoracic spine. Issue 7 (February 2018)
- Record Type:
- Journal Article
- Title:
- Clinical significance of superior articular process as a reference point for free-hand pedicle screw insertion in thoracic spine. Issue 7 (February 2018)
- Main Title:
- Clinical significance of superior articular process as a reference point for free-hand pedicle screw insertion in thoracic spine
- Authors:
- Kim, Tae Hoon
Lee, Suk Ha
Yang, Jae Hyuk
Hong, Jae Young
Suh, Seung Woo - Other Names:
- Grewal. Perbinder section editor.
- Abstract:
- Abstract : Abstract: The trajectory of the pedicle screw perpendicular to the SAP (superior articular process) is consistent with the universal trajectory presented in the previous study of the entry point using computed tomography. The ideal entry point and trajectory of pedicle screw insertion have been a matter of considerable debate. We attempted to find the relationship between SAP and entry point and trajectory of the pedicle screw. Thoracic spine CT (computed tomography) scans of 9 volunteers were studied. A safe zone for the trajectory of the screw in the axial (MarginAx ) and sagittal (MarginSag ) was defined as the zone between lines perpendicular to the SAP along the medial and lateral cortex of the pedicle in the axial section, and the superior and inferior cortex in the sagittal section without violation of the pedicle walls. The midline of MarginAx and MarginSag was defined as the safe entry point of the trajectory in the axial and sagittal planes (TrajectoryAx and TrajectorySag ), respectively. MarginAx and MarginSag were 4.14 ± 0.99 and 9.03 ± 2.01 mm, respectively. There was a statistically significant difference in TrajectoryAx between the upper and middle, and between the upper and lower ( P = .0076 in both cases), but not between the middle and lower thoracic spine ( P = .066). TrajectorySag was within 1 mm at the levels of T4, T8, T11 vertebrae and at 0 mm at the other levels. Thus, the midpoint of MarginSag was within 1 mm from the SAP base. There wasAbstract : Abstract: The trajectory of the pedicle screw perpendicular to the SAP (superior articular process) is consistent with the universal trajectory presented in the previous study of the entry point using computed tomography. The ideal entry point and trajectory of pedicle screw insertion have been a matter of considerable debate. We attempted to find the relationship between SAP and entry point and trajectory of the pedicle screw. Thoracic spine CT (computed tomography) scans of 9 volunteers were studied. A safe zone for the trajectory of the screw in the axial (MarginAx ) and sagittal (MarginSag ) was defined as the zone between lines perpendicular to the SAP along the medial and lateral cortex of the pedicle in the axial section, and the superior and inferior cortex in the sagittal section without violation of the pedicle walls. The midline of MarginAx and MarginSag was defined as the safe entry point of the trajectory in the axial and sagittal planes (TrajectoryAx and TrajectorySag ), respectively. MarginAx and MarginSag were 4.14 ± 0.99 and 9.03 ± 2.01 mm, respectively. There was a statistically significant difference in TrajectoryAx between the upper and middle, and between the upper and lower ( P = .0076 in both cases), but not between the middle and lower thoracic spine ( P = .066). TrajectorySag was within 1 mm at the levels of T4, T8, T11 vertebrae and at 0 mm at the other levels. Thus, the midpoint of MarginSag was within 1 mm from the SAP base. There was a constant angular relationship with the SAP and the pedicle axis; the line perpendicular to the SAP can act as a trajectory. Therefore, we suggest that the SAP might be the only accurate and safe reference for pedicle screw insertion in the thoracic spine perpendicular to the SAP using freehand technique. … (more)
- Is Part Of:
- Medicine. Volume 97:Issue 7(2018)
- Journal:
- Medicine
- Issue:
- Volume 97:Issue 7(2018)
- Issue Display:
- Volume 97, Issue 7 (2018)
- Year:
- 2018
- Volume:
- 97
- Issue:
- 7
- Issue Sort Value:
- 2018-0097-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02
- Subjects:
- pedicle -- perpendicular -- superior articular process -- thoracic spine -- trajectory
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000009907 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15220.xml