Inhalation anesthesia and shielding devices to allow accurate preclinical irradiation of mice with clinical linac-based systems: Design and dosimetric characteristics. (January 2021)
- Record Type:
- Journal Article
- Title:
- Inhalation anesthesia and shielding devices to allow accurate preclinical irradiation of mice with clinical linac-based systems: Design and dosimetric characteristics. (January 2021)
- Main Title:
- Inhalation anesthesia and shielding devices to allow accurate preclinical irradiation of mice with clinical linac-based systems: Design and dosimetric characteristics
- Authors:
- Lagerweij, Tonny
Sewing, Charlotte
van Battum, Leo
Koken, Phil
Heukelom, Stan - Abstract:
- Highlights: Up to twelve mice can be treated simultaneously. Inhalation anesthesia minimizes discomfort, allowing fractionated treatment protocols. The in-house developed devices give accurate radiation doses on the intended areas. Abstract: This technical note describes two devices to enable accurate irradiation of mice on clinical linac-based systems. To study the effects of radiation in murine, preclinical animal models, controlled and accurate dosing is important. This is not only important when specific volumes need to be irradiated, but also when the whole animal body is irradiated. To enable both purposes, we designed two devices. One device to administer Total Body Irradiation (TBI) simultaneously to six, free walking mice, and a second device, denoted as target box, in which we irradiate specific parts of the mice whilst organs-at-risk (OAR) are protected. In this latter device, we can position the mice in multiple ways. One configuration allows to sedate twelve mice simultaneously by isoflurane inhalation anesthesia and protect the body by lead shielding to allow radiation of the head only. Alternatively, the target box can be used to sedate maximal 4 mice simultaneously to irradiate the flank or paws only. All these setups allow high experimental throughput and thus a minimal occupation of the clinical equipment. As measured, the delivered radiation dosages in the regions of interest were accurate for both devices. In this technical note, we describe the designHighlights: Up to twelve mice can be treated simultaneously. Inhalation anesthesia minimizes discomfort, allowing fractionated treatment protocols. The in-house developed devices give accurate radiation doses on the intended areas. Abstract: This technical note describes two devices to enable accurate irradiation of mice on clinical linac-based systems. To study the effects of radiation in murine, preclinical animal models, controlled and accurate dosing is important. This is not only important when specific volumes need to be irradiated, but also when the whole animal body is irradiated. To enable both purposes, we designed two devices. One device to administer Total Body Irradiation (TBI) simultaneously to six, free walking mice, and a second device, denoted as target box, in which we irradiate specific parts of the mice whilst organs-at-risk (OAR) are protected. In this latter device, we can position the mice in multiple ways. One configuration allows to sedate twelve mice simultaneously by isoflurane inhalation anesthesia and protect the body by lead shielding to allow radiation of the head only. Alternatively, the target box can be used to sedate maximal 4 mice simultaneously to irradiate the flank or paws only. All these setups allow high experimental throughput and thus a minimal occupation of the clinical equipment. As measured, the delivered radiation dosages in the regions of interest were accurate for both devices. In this technical note, we describe the design and build of these devices. … (more)
- Is Part Of:
- Clinical and translational radiation oncology. Volume 26(2021)
- Journal:
- Clinical and translational radiation oncology
- Issue:
- Volume 26(2021)
- Issue Display:
- Volume 26, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 26
- Issue:
- 2021
- Issue Sort Value:
- 2021-0026-2021-0000
- Page Start:
- 92
- Page End:
- 97
- Publication Date:
- 2021-01
- Subjects:
- Animal models -- Linac -- Inhalation anesthesia -- Fractionated radiation -- Small animal irradiation devices
Cancer -- Radiotherapy -- Periodicals
Oncology -- Periodicals
Cancer -- Radiotherapy
Oncology
Radiation Oncology
Neoplasms -- radiotherapy
Translational Medical Research
Periodicals
Electronic journals
Periodicals
616.9940642 - Journal URLs:
- https://www.journals.elsevier.com/clinical-and-translational-radiation-oncology ↗
http://www.sciencedirect.com/science/journal/24056308 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ctro.2020.11.012 ↗
- Languages:
- English
- ISSNs:
- 2405-6308
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15207.xml