Differential prognostic accuracy of right ventricular dysfunction, the Seattle heart failure model and the MAGGIC score in patients with severe mitral regurgitation undergoing the MitraClip® procedure. (December 2020)
- Record Type:
- Journal Article
- Title:
- Differential prognostic accuracy of right ventricular dysfunction, the Seattle heart failure model and the MAGGIC score in patients with severe mitral regurgitation undergoing the MitraClip® procedure. (December 2020)
- Main Title:
- Differential prognostic accuracy of right ventricular dysfunction, the Seattle heart failure model and the MAGGIC score in patients with severe mitral regurgitation undergoing the MitraClip® procedure
- Authors:
- Heyl, S.
Luu, B.
Wieszner, M.
Nikkhoo, A.
Seeger, F.
Hemmann, K.
Assmus, B.
Kaess, B.
Zeiher, A.M.
Walther, C.
Fichtlscherer, S.
Honold, J. - Abstract:
- Abstract: Background: MitraClip ® (MC) is an established procedure for severe mitral regurgitation (MR) in patients deemed unsuitable for surgery. Right ventricular dysfunction (RVD) is associated with a higher mortality risk. The prognostic accuracy of heart failure risk scores like the Seattle heart failure model (SHFM) and Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score in pts undergoing MC with or without RVD has not been investigated so far. Methods: SHFM and MAGGIC score were calculated retrospectively. RVD was determined as tricuspid annular plane systolic excursion (TAPSE) ≤15 mm. Area under receiver operating curves (AUROC) of SHFM and MAGGIC were performed for one-year all-cause mortality after MC. Results: N = 103 pts with MR III° (73 ± 11 years, LVEF 37 ± 17%) underwent MC with a reduction of at least I° MR. One-year mortality was 28.2%. In Kaplan-Meier analysis, one- year mortality was significantly higher in RVD-pts (34.8% vs 2.8%, p = 0.009). Area under the Receiver Operating Characteristic (AUROC) for SHFM and MAGGIC were comparable for both scores (SHFM: 0.704, MAGGIC: 0.692). In pts without RVD, SHFM displayed a higher AUROC and therefore better diagnostic accuracy (SHFM: 0.776; MAGGIC: 0.551, p < 0.05). In pts with RVD, MAGGIC and SHFM displayed comparable AUROCs. Conclusion: RVD is an important prognostic marker in pts undergoing MC. SHFM and MAGGIC displayed adequate over-all prognostic power in these pts. Accuracy differed in pts withAbstract: Background: MitraClip ® (MC) is an established procedure for severe mitral regurgitation (MR) in patients deemed unsuitable for surgery. Right ventricular dysfunction (RVD) is associated with a higher mortality risk. The prognostic accuracy of heart failure risk scores like the Seattle heart failure model (SHFM) and Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score in pts undergoing MC with or without RVD has not been investigated so far. Methods: SHFM and MAGGIC score were calculated retrospectively. RVD was determined as tricuspid annular plane systolic excursion (TAPSE) ≤15 mm. Area under receiver operating curves (AUROC) of SHFM and MAGGIC were performed for one-year all-cause mortality after MC. Results: N = 103 pts with MR III° (73 ± 11 years, LVEF 37 ± 17%) underwent MC with a reduction of at least I° MR. One-year mortality was 28.2%. In Kaplan-Meier analysis, one- year mortality was significantly higher in RVD-pts (34.8% vs 2.8%, p = 0.009). Area under the Receiver Operating Characteristic (AUROC) for SHFM and MAGGIC were comparable for both scores (SHFM: 0.704, MAGGIC: 0.692). In pts without RVD, SHFM displayed a higher AUROC and therefore better diagnostic accuracy (SHFM: 0.776; MAGGIC: 0.551, p < 0.05). In pts with RVD, MAGGIC and SHFM displayed comparable AUROCs. Conclusion: RVD is an important prognostic marker in pts undergoing MC. SHFM and MAGGIC displayed adequate over-all prognostic power in these pts. Accuracy differed in pts with and without RVD, indicating higher predictive power of the SHFM score in pts without RVD. … (more)
- Is Part Of:
- IJC heart & vasculature. Volume 31(2021)
- Journal:
- IJC heart & vasculature
- Issue:
- Volume 31(2021)
- Issue Display:
- Volume 31, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 31
- Issue:
- 2021
- Issue Sort Value:
- 2021-0031-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12
- Subjects:
- MitraClip -- Seattle heart failure model -- MAGGIC score -- TAPSE -- Functional mitral regurgitation
Cardiovascular system -- Diseases -- Periodicals
Cardiovascular system -- Pathophysiology -- Periodicals
616.1005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23529067/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ijcha.2020.100641 ↗
- Languages:
- English
- ISSNs:
- 2352-9067
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15201.xml