Evaluation of ferrous benzoic methylthymol-blue gel as a dosimeter via magnetic resonance imaging. (December 2020)
- Record Type:
- Journal Article
- Title:
- Evaluation of ferrous benzoic methylthymol-blue gel as a dosimeter via magnetic resonance imaging. (December 2020)
- Main Title:
- Evaluation of ferrous benzoic methylthymol-blue gel as a dosimeter via magnetic resonance imaging
- Authors:
- Parwaie, Wrya
Geraily, Ghazale
Shirazi, Alireza
Mehri-Kakavand, Ghazal
Farzin, Mostafa - Abstract:
- Highlights: R2 dose–response shows a higher sensitivity compared to R1 dose–response. A notable dependence on scanning temperature was observed at higher doses. R1 and R2 increased significantly immediately to 1.5 h' post-irradiation. Abstract: Purpose: In previous studies, methylthymol-blue and benzoic acid have been introduced as a diffuser limiter and sensitivity enhancer in the gel dosimeter composition, respectively. This work focused on analyzing a formulation of the Fricke gel dosimeter consisting of methylthymol-blue and benzoic acid through magnetic resonance imaging. Methods: The gel dosimeter samples were irradiated using 6, 10, and 15 MV photons with different levels of doses and read using a 1.5 T scanner in order to evaluate the dose–response sensitivity and to study the effect of benzoic acid concentration, diffusion coefficient and temperature and to determine the temporal stability of the gel dosimeter. Results: Inspection of radiological properties revealed that this gel dosimeter can be considered as a tissue equivalent medium. Within the dose range 0 to 1000 cGy, the R1 sensitivity and R2 sensitivity of the gel dosimeter equaled 0.058 ± 0.003 and 0.092 ± 0.004 s −1 Gy −1, respectively. The diffusion coefficient was less than 0.85 ± 0.02mm 2 h −1 for doses higher than 200 cGy. In addition, by changing the temperature from 15C to 25, the R1 sensitivity and R2 sensitivity decreased about 5 and 11%, respectively. Further, no significant energy and dose rateHighlights: R2 dose–response shows a higher sensitivity compared to R1 dose–response. A notable dependence on scanning temperature was observed at higher doses. R1 and R2 increased significantly immediately to 1.5 h' post-irradiation. Abstract: Purpose: In previous studies, methylthymol-blue and benzoic acid have been introduced as a diffuser limiter and sensitivity enhancer in the gel dosimeter composition, respectively. This work focused on analyzing a formulation of the Fricke gel dosimeter consisting of methylthymol-blue and benzoic acid through magnetic resonance imaging. Methods: The gel dosimeter samples were irradiated using 6, 10, and 15 MV photons with different levels of doses and read using a 1.5 T scanner in order to evaluate the dose–response sensitivity and to study the effect of benzoic acid concentration, diffusion coefficient and temperature and to determine the temporal stability of the gel dosimeter. Results: Inspection of radiological properties revealed that this gel dosimeter can be considered as a tissue equivalent medium. Within the dose range 0 to 1000 cGy, the R1 sensitivity and R2 sensitivity of the gel dosimeter equaled 0.058 ± 0.003 and 0.092 ± 0.004 s −1 Gy −1, respectively. The diffusion coefficient was less than 0.85 ± 0.02mm 2 h −1 for doses higher than 200 cGy. In addition, by changing the temperature from 15C to 25, the R1 sensitivity and R2 sensitivity decreased about 5 and 11%, respectively. Further, no significant energy and dose rate dependence were observed over photon energies of 6, 10, and 15 MV and over the range 65 to 525 cGy min −1 . Conclusions: Based on our observation, the ferrous benzoic acid methylthymol-blue gel dosimeter can be suggested to measure the dose distribution. Further analysis is required to clarify its performance in clinical situations. … (more)
- Is Part Of:
- Physica medica. Volume 80(2021)
- Journal:
- Physica medica
- Issue:
- Volume 80(2021)
- Issue Display:
- Volume 80, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 80
- Issue:
- 2021
- Issue Sort Value:
- 2021-0080-2021-0000
- Page Start:
- 47
- Page End:
- 56
- Publication Date:
- 2020-12
- Subjects:
- Fricke gel dosimeter -- Methylthymol-blue -- Benzoic acid -- Magnetic resonance imaging
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.10.006 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15204.xml