Review of skin dose calculation software in interventional cardiology. (December 2020)
- Record Type:
- Journal Article
- Title:
- Review of skin dose calculation software in interventional cardiology. (December 2020)
- Main Title:
- Review of skin dose calculation software in interventional cardiology
- Authors:
- Malchair, Françoise
Dabin, Jérémie
Deleu, Marine
Merce, Marta Sans
Bjelac, Olivera Ciraj
Gallagher, Aoife
Maccia, Carlo - Abstract:
- Highlights: Critical analysis of available Skin Dose Calculation (SDC) software tools. Patient radiation protection in relation to skin dose in interventional cardiology. Review of SDC capabilities to display dose distribution. Abstract: Purpose: In interventional cardiology, patients may be exposed to high doses to the skin resulting in skin burns following single or multiple procedures. Reviewing and analysing available software (online or offline) may help medical physicists assessing the maximum skin dose to the patient together with the dose distribution during (or after) these procedures. Method and results: Capabilities and accuracy of available software were analysed through an extensive bibliography search and contacts with both vendor and authors. Their markedly differed among developers. In total, 22 software were identified and reviewed according to their algorithms and their capabilities. Special attention was dedicated to their main features and limitations of interest for the intended clinical use. While the accuracy of the 12 software products validated with measurements on phantoms was acceptable (within ± 25%), the agreement was poor for the two products validated on patients (within ± 43% and ± 76%, respectively). In addition, no software has been validated on angiographic units from all manufacturers, though several software developers claimed vendor-independent transportability. Only one software allows for multiple procedures dose calculation.Highlights: Critical analysis of available Skin Dose Calculation (SDC) software tools. Patient radiation protection in relation to skin dose in interventional cardiology. Review of SDC capabilities to display dose distribution. Abstract: Purpose: In interventional cardiology, patients may be exposed to high doses to the skin resulting in skin burns following single or multiple procedures. Reviewing and analysing available software (online or offline) may help medical physicists assessing the maximum skin dose to the patient together with the dose distribution during (or after) these procedures. Method and results: Capabilities and accuracy of available software were analysed through an extensive bibliography search and contacts with both vendor and authors. Their markedly differed among developers. In total, 22 software were identified and reviewed according to their algorithms and their capabilities. Special attention was dedicated to their main features and limitations of interest for the intended clinical use. While the accuracy of the 12 software products validated with measurements on phantoms was acceptable (within ± 25%), the agreement was poor for the two products validated on patients (within ± 43% and ± 76%, respectively). In addition, no software has been validated on angiographic units from all manufacturers, though several software developers claimed vendor-independent transportability. Only one software allows for multiple procedures dose calculation. Conclusion: Large differences among vendors made it clear that work remains to be done before an accurate and reliable skin dose mapping is available for all patients. … (more)
- Is Part Of:
- Physica medica. Volume 80(2021)
- Journal:
- Physica medica
- Issue:
- Volume 80(2021)
- Issue Display:
- Volume 80, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 80
- Issue:
- 2021
- Issue Sort Value:
- 2021-0080-2021-0000
- Page Start:
- 75
- Page End:
- 83
- Publication Date:
- 2020-12
- Subjects:
- AC Attenuation Coefficient of table and mattress -- BMI Body-Mass Index -- B Backscatter Factor -- CF Calibration Factor -- DICOM Digital Imaging and Communications in Medicine -- IC Interventional Cardiology -- ICRP International Commission on Radiological Protection -- ICRU International Commission on Radiation Units and measurements -- IEC International Electrotechnical Committee -- Pka kerma-area product -- Ka r, cumulative air kerma at interventional reference point -- KERMA Kinetic Energy Released per unit Mass -- kV kilovoltage -- MSD Maximum Skin Dose -- OSL Optically Stimulated Luminescence -- PA Postero-Anterior -- PERP Patient Entrance Reference Point -- QC Quality Control -- RAO Right Anterior Oblique -- RDSR Radiation Dose Structured Report -- RPL radio‐photoluminescence -- SDC Skin Dose Calculation -- TLD Thermoluminescent Dosimeter
Patient dosimetry -- Interventional cardiology -- Patient dose calculation software -- Radiation protection
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.09.023 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15203.xml