P1552CAN WE GET ADEQUATE DIALYSIS WITH LIQUID AT 300 ML/MIN ?. (6th June 2020)
- Record Type:
- Journal Article
- Title:
- P1552CAN WE GET ADEQUATE DIALYSIS WITH LIQUID AT 300 ML/MIN ?. (6th June 2020)
- Main Title:
- P1552CAN WE GET ADEQUATE DIALYSIS WITH LIQUID AT 300 ML/MIN ?
- Authors:
- Barril, Guillermina
Sobrino, Pedro
Giorgi, Martin
Nuñez, Almudena
Santos, Begoña
Pascual, Natalia
Sanz, Pilar
Cano, Francisco
Nogueira, Angel
Sanchez Tomero, Jose Antonio - Abstract:
- Abstract: Background and Aims: The portable HD monitors achieve a good adaptation with HD dialysate at 200ml / min using the concept of saturation of the HD dialysate. We decrease from 800ml / min to 500ml / min with good adaptation some years ago. To assess the effectiveness of HD in both HD-standard and HDF-online with dialysate flow at 300ml / min by establishing approximate mathematical model of clearance. Methods: We conducted an HD session with dialysate flow at a speed of 300ml / min, half week session to 52 patients in our unit. We value vascular access, session time, liters of blood-purified and total infusion in HDF online. We review HD monitor and dialyzer. We perform pre and postHD blood determinations: Urea, B2microglobulin, P and uric acid, assessing urea reduction rate (PRU), b2microglobulin reduction rate (PR2microg) with both dialysate flows at 300ml / min and 500ml / min. We also have evaluated the differences between the two methods. In the HD dialysate flow we determine at 300ml / min at 5, 10, 30, 45 and 60min (total dialysate collection in the first hour with sample of the mixture) urea, B2microg, Uric acid and P and at 2, 3 and 4 hours establishing a mathematical model with an approximation curve in both HD and online HDF. Results: Five patients in standard HD (4h), 35 HDF online (4h) (x Liters infused 24.87 ± 2.79 l) and 12 short-daily HD (2h30min). 18 catheter and 34 FAV. Xliters purified blood = HD daily 54.41 ± 5.63l, HD standard 87.38 ± 6.01 andAbstract: Background and Aims: The portable HD monitors achieve a good adaptation with HD dialysate at 200ml / min using the concept of saturation of the HD dialysate. We decrease from 800ml / min to 500ml / min with good adaptation some years ago. To assess the effectiveness of HD in both HD-standard and HDF-online with dialysate flow at 300ml / min by establishing approximate mathematical model of clearance. Methods: We conducted an HD session with dialysate flow at a speed of 300ml / min, half week session to 52 patients in our unit. We value vascular access, session time, liters of blood-purified and total infusion in HDF online. We review HD monitor and dialyzer. We perform pre and postHD blood determinations: Urea, B2microglobulin, P and uric acid, assessing urea reduction rate (PRU), b2microglobulin reduction rate (PR2microg) with both dialysate flows at 300ml / min and 500ml / min. We also have evaluated the differences between the two methods. In the HD dialysate flow we determine at 300ml / min at 5, 10, 30, 45 and 60min (total dialysate collection in the first hour with sample of the mixture) urea, B2microg, Uric acid and P and at 2, 3 and 4 hours establishing a mathematical model with an approximation curve in both HD and online HDF. Results: Five patients in standard HD (4h), 35 HDF online (4h) (x Liters infused 24.87 ± 2.79 l) and 12 short-daily HD (2h30min). 18 catheter and 34 FAV. Xliters purified blood = HD daily 54.41 ± 5.63l, HD standard 87.38 ± 6.01 and HDFonline 82.02 ± 16.13l. The xPRU = 76.17 ± 10.49%, PRB2microg = 73.82 ± 13.49, Kt / V = 1.52 ± 0.28. By scheme at 300ml / min of HD fluid flow: HDFonline xPRU = 81.54 ± 5.25, Standard HD = 78.01 ± 3.03, Daily HD = 60.19 ± 6.71; xPRb2microg HDFonline = 76.70 ± 14.76%, Standard HD 65.44 ± 11.81, Daily HD = 69.16 ± 6.49. Comparing the xPRU at 300ml / min of liquid vs 500ml / min we didn´t found significant differences, nor in the x preHD of urea and B2microglobulin. With the dialysate samples we obtain a polynomial model of order 7 allowing cuantitative adjustment of the curve.R2 0.9, observing in the first 2 hours the greater removing. Conclusions: 1. The results are sufficient to consider the result of the removing in each scheme adequate. 2. The decrease in costs would be important (40% of water + energy saving and longer duration elements water treatment. 3. Further study are necessary. … (more)
- Is Part Of:
- Nephrology dialysis transplantation. Volume 35(2020)Supplement 3
- Journal:
- Nephrology dialysis transplantation
- Issue:
- Volume 35(2020)Supplement 3
- Issue Display:
- Volume 35, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 35
- Issue:
- 3
- Issue Sort Value:
- 2020-0035-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-06
- Subjects:
- Nephrology -- Periodicals
Hemodialysis -- Periodicals
Kidneys -- Transplantation -- Periodicals
Hemodialysis
Kidneys -- Transplantation
Nephrology
Periodicals
616.61 - Journal URLs:
- http://ndt.oxfordjournals.org/ ↗
http://www.oup.co.uk/ndt/ ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0931-0509;screen=info;ECOIP ↗ - DOI:
- 10.1093/ndt/gfaa142.P1552 ↗
- Languages:
- English
- ISSNs:
- 0931-0509
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6075.685300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15209.xml