P1117EXPLORATORY COMPARISON OF DIALYSIS EFFICIENCY AT DIFFERENT DIALYSATE FLOW (QD) IN EXPANDED HEMODIALYSIS IN TWO CENTERS IN COLOMBIA. (6th June 2020)
- Record Type:
- Journal Article
- Title:
- P1117EXPLORATORY COMPARISON OF DIALYSIS EFFICIENCY AT DIFFERENT DIALYSATE FLOW (QD) IN EXPANDED HEMODIALYSIS IN TWO CENTERS IN COLOMBIA. (6th June 2020)
- Main Title:
- P1117EXPLORATORY COMPARISON OF DIALYSIS EFFICIENCY AT DIFFERENT DIALYSATE FLOW (QD) IN EXPANDED HEMODIALYSIS IN TWO CENTERS IN COLOMBIA
- Authors:
- Molano Trivino, Alejandra
Zúñiga, Eduardo
Sanabria, Mauricio
Vesga, Jasmin
Ramos, Carolina
Gutiérrez, Juan Felipe
Tran, Ha
Ronco, Claudio
Rivera, Angela - Abstract:
- Abstract: Background and Aims: Dialysate flow rate (Qd) has minimal effect in removal of molecules in hemodialysis, allowing to use lower amounts of dialysate with no effect in clearance of molecules. According to recent literature, Expanded hemodialysis (HDx) improves the clearance of middle size molecules, diminishing the effect of Qd in adequacy. We found no data about clearance at different dialysate flow rates in HDx. Our aim is to evaluate the clearance of middle molecules (beta 2 microglobuline [Mβ2], interleukin-6 [IL-6], interleukin-10 [IL-10 light chains (CLL-κ -λ) with HDx at different Qd using membranes Theranova MR in patients with body weight less than 70 Kg. Method: We performed an observational retrospective analysis of clearance of Mβ2, IL-6, IL-10, CLL-κ; CLL-λ in HDx using Theranova MR filters with Qd 400 mL/min and 500 mL/min. We performed variance analysis, T student test and Wilcoxon test. Data were extracted from an HDx multicentric trial performed in Bogotá, Colombia in 2018. Results: 11 (47%) patients received Qd 400 mL/min and 12 (52.1%) patients with Qd 500ml/min. Demographic data are included in table 1. We found no differences in reduction rate of mid-molecules. (Table 2) We found that lower water consume in the Qd 400 mL/min group, with water savings of 24 Liters/patient (13824 L in 12 weeks of follow up). (Table 3) Conclusion: Expanded hemodialysis seems to allow diminishing Qd rate without changes in mid-size molecules clearance.
- Is Part Of:
- Nephrology dialysis transplantation. Volume 35(2020)Supplement 3
- Journal:
- Nephrology dialysis transplantation
- Issue:
- Volume 35(2020)Supplement 3
- Issue Display:
- Volume 35, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 35
- Issue:
- 3
- Issue Sort Value:
- 2020-0035-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-06-06
- Subjects:
- Nephrology -- Periodicals
Hemodialysis -- Periodicals
Kidneys -- Transplantation -- Periodicals
Hemodialysis
Kidneys -- Transplantation
Nephrology
Periodicals
616.61 - Journal URLs:
- http://ndt.oxfordjournals.org/ ↗
http://www.oup.co.uk/ndt/ ↗
http://ukcatalogue.oup.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0931-0509;screen=info;ECOIP ↗ - DOI:
- 10.1093/ndt/gfaa142.P1117 ↗
- Languages:
- English
- ISSNs:
- 0931-0509
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6075.685300
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15206.xml