- 1211 Assessing the Accuracy of a Dry-EEG Headband for Measuring Brain Activity, Heart Rate, Breathing and Automatic Sleep Staging
- Authors:
- Thorey, V
Guillot, A
El Kanbi, K
Harris, M
Arnal, P J - Abstract:
- Abstract: Introduction: The development of new sleep study devices, adapted for daily use, is necessary for diagnosis of sleep disorders. However, this requires to be both suitable for daily use and capable of recording accurate electrophysiological data. This study assesses the signal acquisition of a comfortable sleep headband, using dry electrodes, and the performance of its automatic sleep staging algorithms compared to the gold-standard clinical PSG scored by 4 sleep experts. Methods: 42 participants slept at a sleep center wearing both the Dreem headband (DH) and a PSG simultaneously. We measured 1) the EEG signal similarity between both devices, 2) heart rate, breathing frequency and respiration rate variability (RRV) agreement, and 3) the performance of the headband automatic sleep scoring compared to PSG sleep experts manual scoring. Results: Results demonstrate a strong correlation between the EEG signals acquired by the headband and those from the PSG, and the signals acquired by the headband enable monitoring of alpha (r= 0.75 ± 0.11), beta (r= 0.74 ± 0.14), delta (r = 0.78 ± 0.16), and theta (r = 0.63 ± 0.15) frequencies during sleep. The mean absolute error for heart rate, breathing frequency, and RRV was 2.2 ± 0.8 bpm, 0.3 ± 0.2 cpm and 3.1 ± 0.4 %, respectively. Automatic Sleep Staging reached an overall accuracy of 84.1 ± 7.5% (F1 score: 83.0 ± 8.4) for the headband to be compared with an average of 86.4 ± 5.5% (F1 score: 86.5 ± 5.5) for the 4 sleep experts.Abstract: Introduction: The development of new sleep study devices, adapted for daily use, is necessary for diagnosis of sleep disorders. However, this requires to be both suitable for daily use and capable of recording accurate electrophysiological data. This study assesses the signal acquisition of a comfortable sleep headband, using dry electrodes, and the performance of its automatic sleep staging algorithms compared to the gold-standard clinical PSG scored by 4 sleep experts. Methods: 42 participants slept at a sleep center wearing both the Dreem headband (DH) and a PSG simultaneously. We measured 1) the EEG signal similarity between both devices, 2) heart rate, breathing frequency and respiration rate variability (RRV) agreement, and 3) the performance of the headband automatic sleep scoring compared to PSG sleep experts manual scoring. Results: Results demonstrate a strong correlation between the EEG signals acquired by the headband and those from the PSG, and the signals acquired by the headband enable monitoring of alpha (r= 0.75 ± 0.11), beta (r= 0.74 ± 0.14), delta (r = 0.78 ± 0.16), and theta (r = 0.63 ± 0.15) frequencies during sleep. The mean absolute error for heart rate, breathing frequency, and RRV was 2.2 ± 0.8 bpm, 0.3 ± 0.2 cpm and 3.1 ± 0.4 %, respectively. Automatic Sleep Staging reached an overall accuracy of 84.1 ± 7.5% (F1 score: 83.0 ± 8.4) for the headband to be compared with an average of 86.4 ± 5.5% (F1 score: 86.5 ± 5.5) for the 4 sleep experts. Conclusion: These results demonstrate the capacity of the headband to both precisely monitor sleep-related physiological signals and process them accurately into sleep stages. This device paves the way for high-quality, large-scale, longitudinal sleep studies. Support: This Study has been supported by Dreem sas. … (more)
- Is Part Of:
- Sleep. Volume 43(2020)Supplement 1
- Journal:
- Sleep
- Issue:
- Volume 43(2020)Supplement 1
- Issue Display:
- Volume 43, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 43
- Issue:
- 1
- Issue Sort Value:
- 2020-0043-0001-0000
- Page Start:
- A463
- Page End:
- A463
- Publication Date:
- 2020-05-27
- Subjects:
- Sleep -- Physiological aspects -- Periodicals
Sleep disorders -- Periodicals
Sommeil -- Aspect physiologique -- Périodiques
Sommeil, Troubles du -- Périodiques
Sleep disorders
Sleep -- Physiological aspects
Sleep -- physiological aspects
Sleep Wake Disorders
Psychophysiology
Electronic journals
Periodicals
616.8498 - Journal URLs:
- http://bibpurl.oclc.org/web/21399 ↗
http://www.journalsleep.org/ ↗
https://academic.oup.com/sleep ↗
http://www.oxfordjournals.org/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=369&action=archive ↗ - DOI:
- 10.1093/sleep/zsaa056.1205 ↗
- Languages:
- English
- ISSNs:
- 0161-8105
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15202.xml