Short-term variability of bisphenols in spot, morning void and 24-hour urine samples. (1st January 2021)
- Record Type:
- Journal Article
- Title:
- Short-term variability of bisphenols in spot, morning void and 24-hour urine samples. (1st January 2021)
- Main Title:
- Short-term variability of bisphenols in spot, morning void and 24-hour urine samples
- Authors:
- Gys, Celine
Bastiaensen, Michiel
Malarvannan, Govindan
Ait Bamai, Yu
Araki, Atsuko
Covaci, Adrian - Abstract:
- Abstract: Due to worldwide regulations on the application of the high production volume industrial chemical bisphenol A (BPA) in various consumer products, alternative bisphenols such as bisphenol F (BPF) and bisphenol S (BPS) are increasingly used. To assess human exposure to these chemicals, biomonitoring of urinary concentrations is frequently used. However, the short-term variability of alternative bisphenols has not been evaluated thoroughly yet, which is essential to achieve a correct estimation of exposure. In this study, we collected all spot urine samples from ten healthy adults for five consecutive days, and an additional 24 h pooled sample. We measured the concentrations of seven bisphenols (BPAF, BPF, BPA, BPB, BPZ, BPS and BPAP) in these samples using gas chromatography coupled to tandem mass spectrometry. BPA, BPF and BPS were frequently found in spot samples (>80%), while bisphenol AP (BPAP) was detected in 43% of spot samples. Calculations of intra-class correlation coefficients (ICCs) showed that reproducibility of these four bisphenols was relatively poor (<0.01–0.200) but improved when concentrations were corrected for urine dilution using creatinine levels (0.128–0.401). Of these four bisphenols, BPF showed the best reproducibility (ICC 0.200–0.439) and BPS the most variability (ICC <0.01–0.128). In general, the within-participant variability of bisphenol levels was the largest contributor to the total variance (47–100%). We compared repeated firstAbstract: Due to worldwide regulations on the application of the high production volume industrial chemical bisphenol A (BPA) in various consumer products, alternative bisphenols such as bisphenol F (BPF) and bisphenol S (BPS) are increasingly used. To assess human exposure to these chemicals, biomonitoring of urinary concentrations is frequently used. However, the short-term variability of alternative bisphenols has not been evaluated thoroughly yet, which is essential to achieve a correct estimation of exposure. In this study, we collected all spot urine samples from ten healthy adults for five consecutive days, and an additional 24 h pooled sample. We measured the concentrations of seven bisphenols (BPAF, BPF, BPA, BPB, BPZ, BPS and BPAP) in these samples using gas chromatography coupled to tandem mass spectrometry. BPA, BPF and BPS were frequently found in spot samples (>80%), while bisphenol AP (BPAP) was detected in 43% of spot samples. Calculations of intra-class correlation coefficients (ICCs) showed that reproducibility of these four bisphenols was relatively poor (<0.01–0.200) but improved when concentrations were corrected for urine dilution using creatinine levels (0.128–0.401). Of these four bisphenols, BPF showed the best reproducibility (ICC 0.200–0.439) and BPS the most variability (ICC <0.01–0.128). In general, the within-participant variability of bisphenol levels was the largest contributor to the total variance (47–100%). We compared repeated first morning voids to 24 h pooled urine and found no significantly different concentrations for BPA, BPF, BPS, or BPAP. Levels of BPA and BPF differed significantly depending on the sampling time throughout the day. The findings in this study suggest that collecting multiple samples per participant over a few days, in predefined time windows throughout the day, could result in a more reliable estimation of internal exposure to bisphenols. Graphical abstract: Image 1 Highlights: Seven bisphenols measured in spot, morning void and 24 h pooled urine. Reproducibility of urinary bisphenols was relatively poor (ICC <0.01–0.439). Creatinine correction resulted in better reproducibility than for specific gravity. BPA and BPF levels differed significantly depending on the time of day. No significant difference in levels between morning voids and 24-h pooled urine. Abstract : Levels of BPA, BPF and BPS differed significantly depending on the sampling time throughout the day and between days. … (more)
- Is Part Of:
- Environmental pollution. Volume 268(2021)Part A
- Journal:
- Environmental pollution
- Issue:
- Volume 268(2021)Part A
- Issue Display:
- Volume 268, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 268
- Issue:
- 2021
- Issue Sort Value:
- 2021-0268-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01-01
- Subjects:
- Bisphenols -- Variability -- Urine -- Intra-class correlation coefficient -- Biomonitoring
Pollution -- Periodicals
Pollution -- Environmental aspects -- Periodicals
Environmental Pollution -- Periodicals
Pollution -- Périodiques
Pollution -- Aspect de l'environnement -- Périodiques
Pollution -- Effets physiologiques -- Périodiques
Pollution
Pollution -- Environmental aspects
Periodicals
Electronic journals
363.73 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02697491 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.envpol.2020.115747 ↗
- Languages:
- English
- ISSNs:
- 0269-7491
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3791.539000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15190.xml