Biomechanical effects of posterior pedicle screw-based instrumentation using titanium versus carbon fiber reinforced PEEK in an osteoporotic spine human cadaver model. (December 2020)
- Record Type:
- Journal Article
- Title:
- Biomechanical effects of posterior pedicle screw-based instrumentation using titanium versus carbon fiber reinforced PEEK in an osteoporotic spine human cadaver model. (December 2020)
- Main Title:
- Biomechanical effects of posterior pedicle screw-based instrumentation using titanium versus carbon fiber reinforced PEEK in an osteoporotic spine human cadaver model
- Authors:
- Oikonomidis, Stavros
Greven, Johannes
Bredow, Jan
Eh, Madita
Prescher, Andreas
Fischer, Horst
Thüring, Johannes
Eysel, Peer
Hildebrand, Frank
Kobbe, Philipp
Scheyerer, Max Joseph
Herren, Christian - Abstract:
- Abstract: Background: Aim of this biomechanical investigation was to compare the biomechanical effects of a carbon fiber reinforced PEEK and titanium pedicle screw/rod device in osteoporotic human cadaveric spine. Methods: Ten human fresh-frozen cadaveric lumbar spines (L1-L5) have been used and were randomized into two groups according to the bone mineral density. A monosegmental posterior instrumentation (L3-L4) using titanium pedicle screws and rods was carried out in group A and using carbon fiber reinforced PEEK in group B. A cyclic loading test was performed at a frequency of 3 Hz, starting with a peak of 500 N for the first 2000 cycles, up to 950 N for 100, 000 cycles under a general preload with 100 N. All specimens were evaluated with regard to a potential collapse of the implanted pedicle screws. A CT supported digital measurement of cavities around the pedicle at 3 defined measuring points was performed. Finally, the maximum zero-time failure load of all specimens was determined using a universal testing machine (80% Fmax ). Findings: Regarding maximum axial force (group A: 2835 N, group B: 3006 N, p = 0.595) and maximum compression (group A: 11.67 mm, group B: 15.15 mm, p = 0.174) no statistical difference could be shown between the two groups. However, significant smaller cavity formation around the pedicle screws could be observed in group B ( p = 0.007), especially around the screw tip ( p < 0.001). Interpretation: Carbon fiber reinforced PEEK devices seemAbstract: Background: Aim of this biomechanical investigation was to compare the biomechanical effects of a carbon fiber reinforced PEEK and titanium pedicle screw/rod device in osteoporotic human cadaveric spine. Methods: Ten human fresh-frozen cadaveric lumbar spines (L1-L5) have been used and were randomized into two groups according to the bone mineral density. A monosegmental posterior instrumentation (L3-L4) using titanium pedicle screws and rods was carried out in group A and using carbon fiber reinforced PEEK in group B. A cyclic loading test was performed at a frequency of 3 Hz, starting with a peak of 500 N for the first 2000 cycles, up to 950 N for 100, 000 cycles under a general preload with 100 N. All specimens were evaluated with regard to a potential collapse of the implanted pedicle screws. A CT supported digital measurement of cavities around the pedicle at 3 defined measuring points was performed. Finally, the maximum zero-time failure load of all specimens was determined using a universal testing machine (80% Fmax ). Findings: Regarding maximum axial force (group A: 2835 N, group B: 3006 N, p = 0.595) and maximum compression (group A: 11.67 mm, group B: 15.15 mm, p = 0.174) no statistical difference could be shown between the two groups. However, significant smaller cavity formation around the pedicle screws could be observed in group B ( p = 0.007), especially around the screw tip ( p < 0.001). Interpretation: Carbon fiber reinforced PEEK devices seem to be advantageous in terms of microscopic screw loosening compared to titanium devices. Highlights: Biomechanical study of carbon fiber reinforced PEEK and titanium instrumentations. Carbon fiber reinforced PEEK leads to less microscopic screw loosening. Carbon fiber reinforced PEEK shows biomechanical advantages in osteoporotic spine. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 80(2020)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 80(2020)
- Issue Display:
- Volume 80, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 80
- Issue:
- 2020
- Issue Sort Value:
- 2020-0080-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12
- Subjects:
- Carbon fiber reinforced PEEK -- Osteoporosis -- PEEK -- Pedicle screw -- Pedicle screw loosening -- Titanium spinal implants
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2020.105153 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15191.xml