Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator. (January 2021)
- Record Type:
- Journal Article
- Title:
- Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator. (January 2021)
- Main Title:
- Comparison between PRIMO and EGSnrc Monte Carlo models of the Varian True Beam linear accelerator
- Authors:
- Aamri, Hussin
Fielding, Andrew
Aamry, Ali
Sulieman, Abdelmoneim
Tamam, Nissren
Alkhorayef, Mohammed
Bradley, David A. - Abstract:
- Abstract: The study objectives were to simulate a 6 MV flattening filter-free (FFF) photon beam of a TrueBeam Varian LINAC, using the PRIMO code. The depth-dose profiles for various jaw open fields and cross-beam profiles for various depths inside water phantoms were determined using PRIMO simulations and were compared with the EGSnrc simulation results. A 93% match between both codes has generally been obtained, with a systematic variation in agreement between the two models that increases with field size. The closest agreement, to within 94%, was obtained for a 6 × 6 cm 2 jaw open field at 5.0 cm and 10.0 cm depths, better at 10- than at 5.0 cm depth. The effects of how scatter is modelled has been shown to result in the differences. Highlights: 6 MV flattening filter-free photon beam of a TrueBeam Varian LINAC was simulated. PRIMO code simulations were compared with the EGSnrc simulation results. A 93% match being between both codes has generally been obtained. PRIMO can be successfully used as an alternative code for dosimetric calculations.
- Is Part Of:
- Radiation physics and chemistry. Volume 178(2021)
- Journal:
- Radiation physics and chemistry
- Issue:
- Volume 178(2021)
- Issue Display:
- Volume 178, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 178
- Issue:
- 2021
- Issue Sort Value:
- 2021-0178-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01
- Subjects:
- Monte Carlo simulation -- Flattening-filter free (FFF) -- Linear accelerator (LINAC) -- EGSnrc -- Dose in build-up region -- PRIMO Code.
Radiation chemistry -- Periodicals
Radiometry -- Periodicals
Radiation -- Periodicals
Chimie sous rayonnement -- Périodiques
539.2 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0969806X ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-physics-and-chemistry/ ↗ - DOI:
- 10.1016/j.radphyschem.2020.109013 ↗
- Languages:
- English
- ISSNs:
- 0969-806X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.984000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15188.xml