A deep learning approach to generate synthetic CT in low field MR-guided adaptive radiotherapy for abdominal and pelvic cases. (December 2020)
- Record Type:
- Journal Article
- Title:
- A deep learning approach to generate synthetic CT in low field MR-guided adaptive radiotherapy for abdominal and pelvic cases. (December 2020)
- Main Title:
- A deep learning approach to generate synthetic CT in low field MR-guided adaptive radiotherapy for abdominal and pelvic cases
- Authors:
- Cusumano, Davide
Lenkowicz, Jacopo
Votta, Claudio
Boldrini, Luca
Placidi, Lorenzo
Catucci, Francesco
Dinapoli, Nicola
Antonelli, Marco Valerio
Romano, Angela
De Luca, Viola
Chiloiro, Giuditta
Indovina, Luca
Valentini, Vincenzo - Abstract:
- Highlights: We propose a deep learning approach to generate synthetic CT from low tesla MR images. Synthetic CT was created for pelvic and abdominal lesions enrolling 120 cases. The images generated show an accuracy sufficient to safely calculate IMRT plans. This study represents the first experience of CT generation from low tesla MR images. This is the first experience of CT generation in abdomen independently by B intensity. Abstract: Purpose: Artificial intelligence (AI) can play a significant role in Magnetic Resonance guided Radiotherapy (MRgRT), especially to speed up the online adaptive workflow. The aim of this study is to set up a Deep Learning (DL) approach able to generate synthetic computed tomography (sCT) images from low field MR images in pelvis and abdomen. Methods: A conditional Generative Adversarial Network (cGAN) was used for sCT generation: a total of 120 patients treated on pelvic and abdominal sites were enrolled and divided in training (80) and test sets (40). Intensity modulated radiotherapy (IMRT) treatment plans were calculated on sCT and original CT and then compared in terms of gamma analysis and differences in Dose Volume Histogram (DVH). The two one-sided test for paired samples (TOST-P) was used to evaluate the equivalence among different DVH parameters calculated for target and organs at risks (OAR) on CT and sCT images. Results: Using a CPU architecture, the mean time required by the neural network to generate a synthetic CT was 175 ± 43Highlights: We propose a deep learning approach to generate synthetic CT from low tesla MR images. Synthetic CT was created for pelvic and abdominal lesions enrolling 120 cases. The images generated show an accuracy sufficient to safely calculate IMRT plans. This study represents the first experience of CT generation from low tesla MR images. This is the first experience of CT generation in abdomen independently by B intensity. Abstract: Purpose: Artificial intelligence (AI) can play a significant role in Magnetic Resonance guided Radiotherapy (MRgRT), especially to speed up the online adaptive workflow. The aim of this study is to set up a Deep Learning (DL) approach able to generate synthetic computed tomography (sCT) images from low field MR images in pelvis and abdomen. Methods: A conditional Generative Adversarial Network (cGAN) was used for sCT generation: a total of 120 patients treated on pelvic and abdominal sites were enrolled and divided in training (80) and test sets (40). Intensity modulated radiotherapy (IMRT) treatment plans were calculated on sCT and original CT and then compared in terms of gamma analysis and differences in Dose Volume Histogram (DVH). The two one-sided test for paired samples (TOST-P) was used to evaluate the equivalence among different DVH parameters calculated for target and organs at risks (OAR) on CT and sCT images. Results: Using a CPU architecture, the mean time required by the neural network to generate a synthetic CT was 175 ± 43 seconds (s) for pelvic cases and 110 ± 40 s for abdominal ones. Mean gamma passing rates for the three tolerance criteria analysed (1%/1 mm, 2%/2 mm and 3%/3 mm) were respectively 90.8 ± 4.5%, 98.7 ± 1.1% and 99.8 ± 0.2% for abdominal cases; 89.3 ± 4.8%, 99.0 ± 0.7% and 99.9 ± 0.2% for pelvic ones, while equivalence within 1% was observed among the DVH indicators. Conclusion: This study demonstrated that sCT generation using a DL approach is feasible for low field MR images in pelvis and abdomen, allowing a reliable calculation of IMRT plans in MRgRT. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 153(2020)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 153(2020)
- Issue Display:
- Volume 153, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 153
- Issue:
- 2020
- Issue Sort Value:
- 2020-0153-2020-0000
- Page Start:
- 205
- Page End:
- 212
- Publication Date:
- 2020-12
- Subjects:
- Deep learning -- CT generation -- MR-only radiotherapy -- MR-guided radiotherapy
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2020.10.018 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15189.xml