Assessment of injury current during leadless pacemaker implantation. (15th January 2021)
- Record Type:
- Journal Article
- Title:
- Assessment of injury current during leadless pacemaker implantation. (15th January 2021)
- Main Title:
- Assessment of injury current during leadless pacemaker implantation
- Authors:
- Breitenstein, Alexander
Saguner, Ardan M.
Gasperetti, Alessio
Hofer, Daniel
Koepfli, Pascal
Regoli, François
Steffel, Jan - Abstract:
- Abstract: Background: Leadless pacemakers are an established treatment option for bradyarrhythmias. Similar to conventional transvenous pacemakers, satisfying pacing values during implantation are targeted for optimal long-term device function. The objective is to investigate the role of a local injury current (IC) in leadless pacemaker implantations. Method: The IC, sensing value, capture threshold and impedance were collected in 30 consecutive patients receiving a leadless pacemaker. Results: 39 EGMs were recorded from 30 patients (including 9 device repositions). An IC was detected in 15 cases (38%). At implantation, the presence of an IC was associated with a significantly lower sensing (7.1 ± 3.7 mV vs 12.0 ± 4.0 mV; P = 0.004) and a higher capture threshold (median threshold 1.13 V at 0.24 ms [0.50–2.00] vs 0.50 V at 0.24 ms [0.25–0.75]; P = 0.002) and with a 26 fold higher likelihood of device repositioning compared to the absence of an IC (OR 26.3 [2.79–248], P < 0.001). Patients with an IC in their final implant position had a lower sensing (9.3 ± 4.4 mV vs 13.6 ± 4.7 mV at implantation, P = 0.04), while the initially similar capture threshold was lower after 24 h in the IC group. After 2 weeks, all parameters were similar between the two groups. Conclusions: Our study shows that an IC can readily be observed during leadless pacemaker implantation associated with a lower sensing and a higher capture threshold at implantation but with similar to even betterAbstract: Background: Leadless pacemakers are an established treatment option for bradyarrhythmias. Similar to conventional transvenous pacemakers, satisfying pacing values during implantation are targeted for optimal long-term device function. The objective is to investigate the role of a local injury current (IC) in leadless pacemaker implantations. Method: The IC, sensing value, capture threshold and impedance were collected in 30 consecutive patients receiving a leadless pacemaker. Results: 39 EGMs were recorded from 30 patients (including 9 device repositions). An IC was detected in 15 cases (38%). At implantation, the presence of an IC was associated with a significantly lower sensing (7.1 ± 3.7 mV vs 12.0 ± 4.0 mV; P = 0.004) and a higher capture threshold (median threshold 1.13 V at 0.24 ms [0.50–2.00] vs 0.50 V at 0.24 ms [0.25–0.75]; P = 0.002) and with a 26 fold higher likelihood of device repositioning compared to the absence of an IC (OR 26.3 [2.79–248], P < 0.001). Patients with an IC in their final implant position had a lower sensing (9.3 ± 4.4 mV vs 13.6 ± 4.7 mV at implantation, P = 0.04), while the initially similar capture threshold was lower after 24 h in the IC group. After 2 weeks, all parameters were similar between the two groups. Conclusions: Our study shows that an IC can readily be observed during leadless pacemaker implantation associated with a lower sensing and a higher capture threshold at implantation but with similar to even better values during follow-up. Highlights: A local injury current can be observed during leadless pacemaker implantation It's presence is associated with impaired ventricular sensing and capture threshold at implantation, but improves over time This observation is relevant because unnecessary device repositioning could be avoided … (more)
- Is Part Of:
- International journal of cardiology. Volume 323(2021)
- Journal:
- International journal of cardiology
- Issue:
- Volume 323(2021)
- Issue Display:
- Volume 323, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 323
- Issue:
- 2021
- Issue Sort Value:
- 2021-0323-2021-0000
- Page Start:
- 113
- Page End:
- 117
- Publication Date:
- 2021-01-15
- Subjects:
- Leadless pacemaker -- Injury current -- Device implantation
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2020.08.098 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15189.xml