Diffusion-Weighted Imaging for the Discrimination of Benign and Malignant Breast Masses; Utility of ADC and Relative ADC. Issue 1 (7th February 2018)
- Record Type:
- Journal Article
- Title:
- Diffusion-Weighted Imaging for the Discrimination of Benign and Malignant Breast Masses; Utility of ADC and Relative ADC. Issue 1 (7th February 2018)
- Main Title:
- Diffusion-Weighted Imaging for the Discrimination of Benign and Malignant Breast Masses; Utility of ADC and Relative ADC
- Authors:
- Yılmaz, Ebru
Sarı, Ozcan
Yılmaz, Ayhan
Ucar, Nese
Aslan, Ahmet
Inan, Ibrahim
Parlakkılıc, Ulku Tuba - Abstract:
- Purpose: To determine the contribution of apparent diffusion coefficient (ADC), and relative ADC (rADC) values to differentiate between benign and malignant breast masses. Materials and Methods: Magnetic resonance imaging (MRI) of the breast with diffusion-weighted imaging (DWI) of patients with benign or malignant breast masses diagnosed either by histopathological findings or by follow-up imaging were evaluated retrospectively. Histopathological analyses were performed for 71 lesions (80.7%) while the remaining were followed up every six months for one year. DWI was performed using b-values of 0 and 1000 sec/mm 2, and ADC and rADC were calculated and compared. A receiver operating characteristic (ROC) curve and Youden index were used to evaluate the parameter's optimal threshold and diagnostic value. Statistical significance was set as p < 0.05. Results: Eighty-eight lesions from a total of 81 patients, aged between 16 and 73 (mean age 42 ± 11.3) years were obtained and evaluated. Pathological results of 34 (38.6%) out of 71 lesions were malignant and 37 lesions (42%) were benign. Seventeen (19.3%) lesions remained stable at one-year follow-up and were accepted as benign breast masses. Mean ADC values of benign and malignant lesions were 1.584 × 10 –3 mm 2 /sec and 0.884 × 10 –3 mm 2 /sec (p < 0.05), respectively. Sensitivity and specificity of ADC were 88% and 87%, respectively at a cut-off value of 1.04 × 10 –3 mm 2 /sec. Mean rADC was 0.931 for benign lesions and 0.557Purpose: To determine the contribution of apparent diffusion coefficient (ADC), and relative ADC (rADC) values to differentiate between benign and malignant breast masses. Materials and Methods: Magnetic resonance imaging (MRI) of the breast with diffusion-weighted imaging (DWI) of patients with benign or malignant breast masses diagnosed either by histopathological findings or by follow-up imaging were evaluated retrospectively. Histopathological analyses were performed for 71 lesions (80.7%) while the remaining were followed up every six months for one year. DWI was performed using b-values of 0 and 1000 sec/mm 2, and ADC and rADC were calculated and compared. A receiver operating characteristic (ROC) curve and Youden index were used to evaluate the parameter's optimal threshold and diagnostic value. Statistical significance was set as p < 0.05. Results: Eighty-eight lesions from a total of 81 patients, aged between 16 and 73 (mean age 42 ± 11.3) years were obtained and evaluated. Pathological results of 34 (38.6%) out of 71 lesions were malignant and 37 lesions (42%) were benign. Seventeen (19.3%) lesions remained stable at one-year follow-up and were accepted as benign breast masses. Mean ADC values of benign and malignant lesions were 1.584 × 10 –3 mm 2 /sec and 0.884 × 10 –3 mm 2 /sec (p < 0.05), respectively. Sensitivity and specificity of ADC were 88% and 87%, respectively at a cut-off value of 1.04 × 10 –3 mm 2 /sec. Mean rADC was 0.931 for benign lesions and 0.557 for malignant lesions (p < 0.05). Sensitivity and specificity were 82% and 83% at a cut-off value of 0.639. No prominent superiority of rADC over ADC is identified in the differentiation of breast masses. Conclusion: ADC and rADC values derived from DWI can be equally useful in clinical setting to differentiate benign from malignant breast masses. … (more)
- Is Part Of:
- Journal of the Belgian Society of Radiology. Volume 102:Issue 1(2018)
- Journal:
- Journal of the Belgian Society of Radiology
- Issue:
- Volume 102:Issue 1(2018)
- Issue Display:
- Volume 102, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 102
- Issue:
- 1
- Issue Sort Value:
- 2018-0102-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02-07
- Subjects:
- Breast MRI -- Breast cancer -- Diffusion-weighted imaging -- Apparent diffusion coefficient (ADC) -- Relative ADC
Radiology -- Periodicals
Periodicals
616.0757 - Journal URLs:
- http://www.jbsr.be/ ↗
- DOI:
- 10.5334/jbsr.1258 ↗
- Languages:
- English
- ISSNs:
- 2514-8281
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 15186.xml