Are all certified EHRs created equal? Assessing the relationship between EHR vendor and hospital meaningful use performance. (24th November 2017)
- Record Type:
- Journal Article
- Title:
- Are all certified EHRs created equal? Assessing the relationship between EHR vendor and hospital meaningful use performance. (24th November 2017)
- Main Title:
- Are all certified EHRs created equal? Assessing the relationship between EHR vendor and hospital meaningful use performance
- Authors:
- Holmgren, A Jay
Adler-Milstein, Julia
McCullough, Jeffrey - Abstract:
- Abstract: Objective: The federal electronic health record (EHR) certification process was intended to ensure a baseline level of system quality and the ability to support meaningful use criteria. We sought to assess whether there was variation across EHR vendors in the degree to which hospitals using products from those vendors were able to achieve high levels of performance on meaningful use criteria. Materials and Methods: We created a cross-sectional national hospital sample from the Office of the National Coordinator for Health Information Technology EHR Products Used for Meaningful Use Attestation public use file and the Centers for Medicare & Medicaid Services Medicare EHR Incentive Program Eligible Hospitals public use file. We used regression models to assess the relationship between vendor and hospital performance on 6 Stage 2 Meaningful Use criteria, controlling for hospital characteristics. We also calculated how much variation in performance is explained by vendor choice. Results: We found significant associations between specific vendor and level of hospital performance for all 6 meaningful use criteria. Epic was associated with significantly higher performance on 5 of the 6 criteria; relationships for other vendors were mixed, with some associated with significantly worse performance on multiple criteria. EHR vendor choice accounted for between 7% and 34% of performance variation across the 6 criteria. Discussion: A nontrivial proportion of variation inAbstract: Objective: The federal electronic health record (EHR) certification process was intended to ensure a baseline level of system quality and the ability to support meaningful use criteria. We sought to assess whether there was variation across EHR vendors in the degree to which hospitals using products from those vendors were able to achieve high levels of performance on meaningful use criteria. Materials and Methods: We created a cross-sectional national hospital sample from the Office of the National Coordinator for Health Information Technology EHR Products Used for Meaningful Use Attestation public use file and the Centers for Medicare & Medicaid Services Medicare EHR Incentive Program Eligible Hospitals public use file. We used regression models to assess the relationship between vendor and hospital performance on 6 Stage 2 Meaningful Use criteria, controlling for hospital characteristics. We also calculated how much variation in performance is explained by vendor choice. Results: We found significant associations between specific vendor and level of hospital performance for all 6 meaningful use criteria. Epic was associated with significantly higher performance on 5 of the 6 criteria; relationships for other vendors were mixed, with some associated with significantly worse performance on multiple criteria. EHR vendor choice accounted for between 7% and 34% of performance variation across the 6 criteria. Discussion: A nontrivial proportion of variation in hospital meaningful use performance is explained by vendor choice, and certain vendors are more often associated with better meaningful use performance than others. Our results suggest that policy-makers should improve the certification process by including more "real-world" scenario testing and provider feedback or ratings to reduce this variation. Hospitals can use these results to guide interactions with vendors. Conclusion: Vendor choice accounts for a meaningful proportion of variation in hospital meaningful use performance, and specific vendors are consistently associated with higher or lower performance across criteria. … (more)
- Is Part Of:
- Journal of the American Medical Informatics Association. Volume 25:Number 6(2018)
- Journal:
- Journal of the American Medical Informatics Association
- Issue:
- Volume 25:Number 6(2018)
- Issue Display:
- Volume 25, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 25
- Issue:
- 6
- Issue Sort Value:
- 2018-0025-0006-0000
- Page Start:
- 654
- Page End:
- 660
- Publication Date:
- 2017-11-24
- Subjects:
- electronic health records -- hospitals -- EHR performance -- meaningful use
Medical informatics -- Periodicals
Information Services -- Periodicals
Medical Informatics -- Periodicals
Médecine -- Informatique -- Périodiques
Informatica
Geneeskunde
Informatique médicale
Computer network resources
Electronic journals
610.285 - Journal URLs:
- http://jamia.bmj.com/ ↗
http://www.jamia.org ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=76 ↗
http://www.sciencedirect.com/science/journal/10675027 ↗
http://jamia.oxfordjournals.org/ ↗
http://www.oxfordjournals.org/en/ ↗ - DOI:
- 10.1093/jamia/ocx135 ↗
- Languages:
- English
- ISSNs:
- 1067-5027
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4689.025000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15181.xml