Echocardiographic versus angiographic measurement of the aortic valve annulus in children undergoing balloon aortic valvuloplasty: method affects outcomes. (14th December 2020)
- Record Type:
- Journal Article
- Title:
- Echocardiographic versus angiographic measurement of the aortic valve annulus in children undergoing balloon aortic valvuloplasty: method affects outcomes. (14th December 2020)
- Main Title:
- Echocardiographic versus angiographic measurement of the aortic valve annulus in children undergoing balloon aortic valvuloplasty: method affects outcomes
- Authors:
- Nicholson, George T.
Goldstein, Bryan H.
Gao, Kevin
Sachdeva, Ritu
Lang, Sean M.
Gillespie, Scott
Kim, Sung-in H.
Petit, Christopher J. - Abstract:
- Abstract: Objective: Operators are mindful of the balloon-to-aortic annulus ratio when performing balloon aortic valvuloplasty. The method of measurement of the aortic valve annulus has not been standardised. Methods and results: Patients who underwent aortic valvuloplasty at two paediatric centres between 2007 and 2014 were included. The valve annulus measured by echocardiography and angiography was used to calculate the balloon-to-aortic annulus ratio and measurements were compared. The primary endpoint was an increase in aortic insufficiency by ≥2 degrees. Ninety-eight patients with a median age at valvuloplasty of 2.1 months (Interquartile range (IQR): 0.2–105.5) were included. The angiographic-based annulus was 8.2 mm (IQR: 6.8–16.0), which was greater than echocardiogram-based annulus of 7.5 mm (IQR: 6.1–14.8) (p < 0.001). This corresponded to a significantly lower angiographic balloon-to-aortic annulus ratio of 0.9 (IQR: 0.9–1.0), compared to an echocardiographic ratio of 1.1 (IQR: 1.0–1.1) (p < 0.001). The degree of discrepancy in measured diameter increased with smaller valve diameters (p = 0.041) and in neonates (p = 0.044). There was significant disagreement between angiographic and echocardiographic balloon-to-aortic annulus ratio measures regarding "High" ratio of >1.2, with angiographic ratio flagging only 2/12 (16.7%) of patients flagged by echocardiographic ratio as "High" (p = 0.012). Patients who had an increase in the degree of aortic insufficiency postAbstract: Objective: Operators are mindful of the balloon-to-aortic annulus ratio when performing balloon aortic valvuloplasty. The method of measurement of the aortic valve annulus has not been standardised. Methods and results: Patients who underwent aortic valvuloplasty at two paediatric centres between 2007 and 2014 were included. The valve annulus measured by echocardiography and angiography was used to calculate the balloon-to-aortic annulus ratio and measurements were compared. The primary endpoint was an increase in aortic insufficiency by ≥2 degrees. Ninety-eight patients with a median age at valvuloplasty of 2.1 months (Interquartile range (IQR): 0.2–105.5) were included. The angiographic-based annulus was 8.2 mm (IQR: 6.8–16.0), which was greater than echocardiogram-based annulus of 7.5 mm (IQR: 6.1–14.8) (p < 0.001). This corresponded to a significantly lower angiographic balloon-to-aortic annulus ratio of 0.9 (IQR: 0.9–1.0), compared to an echocardiographic ratio of 1.1 (IQR: 1.0–1.1) (p < 0.001). The degree of discrepancy in measured diameter increased with smaller valve diameters (p = 0.041) and in neonates (p = 0.044). There was significant disagreement between angiographic and echocardiographic balloon-to-aortic annulus ratio measures regarding "High" ratio of >1.2, with angiographic ratio flagging only 2/12 (16.7%) of patients flagged by echocardiographic ratio as "High" (p = 0.012). Patients who had an increase in the degree of aortic insufficiency post valvuloplasty, only 3 (5.5%) had angiographic ratio > 1.1, while 21 (38%) had echocardiographic ratio >1.1 (p < 0.001). Patients with resultant ≥ moderate insufficiency more often had an echocardiographic ratio of >1.1 than angiographic ratio of >1.1 There was no association between increase in balloon-to-aortic annulus ratio and gradient reduction. Conclusions: Angiographic measurement is associated with a greater measured aortic valve annulus and the development of aortic insufficiency. Operators should use caution when relying solely on angiographic measurement when performing balloon aortic valvuloplasty. … (more)
- Is Part Of:
- Cardiology in the young. Volume 30:Number 12(2020)
- Journal:
- Cardiology in the young
- Issue:
- Volume 30:Number 12(2020)
- Issue Display:
- Volume 30, Issue 12 (2020)
- Year:
- 2020
- Volume:
- 30
- Issue:
- 12
- Issue Sort Value:
- 2020-0030-0012-0000
- Page Start:
- 1923
- Page End:
- 1929
- Publication Date:
- 2020-12-14
- Subjects:
- Aortic valve disease, -- CHD, -- paediatric intervention
Pediatric cardiology -- Periodicals
618.9212 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=CTY ↗
- DOI:
- 10.1017/S1047951120003194 ↗
- Languages:
- English
- ISSNs:
- 1047-9511
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital Store
- Ingest File:
- 15170.xml