Taylor Spatial Frame or Reamed Intramedullary Nailing for Closed Fractures of the Tibial Shaft: A Randomized Controlled Trial. Issue 11 (November 2020)
- Record Type:
- Journal Article
- Title:
- Taylor Spatial Frame or Reamed Intramedullary Nailing for Closed Fractures of the Tibial Shaft: A Randomized Controlled Trial. Issue 11 (November 2020)
- Main Title:
- Taylor Spatial Frame or Reamed Intramedullary Nailing for Closed Fractures of the Tibial Shaft
- Authors:
- Frihagen, Frede
Madsen, Jan E.
Sundfeldt, Mikael
Flugsrud, Gunnar B.
Andreassen, Joakim S.
Andersen, Mette R.
Andreassen, Geir S. - Abstract:
- Abstract : Objectives: To compare a modern ring fixator [Taylor Spatial Frame (TSF)] and reamed intramedullary nailing (IMN) for the treatment of closed tibial shaft fractures. Design: Randomized controlled trial. Setting: Two university hospitals. Patients: Patients between 18 and 70 years of age surgically treated for an acute tibial shaft fracture. Intervention: TSF (n = 31) versus a reamed intramedullary nail (n = 32). The patients were followed up for 2 years. Main Outcome Measurements: The physical component summary of Short Form 36 (SF-36) at 2 years was the primary outcome measure. Secondary outcomes included the other components of the SF-36, pain assessed by a visual analogue scale (VAS), complications, and resource consumption. Results: The mean age was 43 years (SD 14.0), and 42 (67%) were men. The physical component summary at 2 years was 52.4 (SD 6.3) in the TSF group and 53.3 (SD 8.0) in the IMN group ( P = 0.35). There were modest differences in the other SF-36 scores during the follow-up period. Up to and including 12 months, the TSF group had less knee pain [at 12 months: VAS 0.5 (SD 1.2) vs. VAS 2.4 (SD 2.2; P < 0.001)], but this was not statistically significant at 24 months [VAS 0.7 (SD 1.4) vs. VAS 1.5 (SD 2.0; P = 0.11)]. Superficial skin infections were more frequent in the TSF group [22 (71%) vs. 4 (13%); P < 0.001]. The number of other complications was similar between the groups. Conclusions: Both TSF and IMN provided good clinical results. TSF hadAbstract : Objectives: To compare a modern ring fixator [Taylor Spatial Frame (TSF)] and reamed intramedullary nailing (IMN) for the treatment of closed tibial shaft fractures. Design: Randomized controlled trial. Setting: Two university hospitals. Patients: Patients between 18 and 70 years of age surgically treated for an acute tibial shaft fracture. Intervention: TSF (n = 31) versus a reamed intramedullary nail (n = 32). The patients were followed up for 2 years. Main Outcome Measurements: The physical component summary of Short Form 36 (SF-36) at 2 years was the primary outcome measure. Secondary outcomes included the other components of the SF-36, pain assessed by a visual analogue scale (VAS), complications, and resource consumption. Results: The mean age was 43 years (SD 14.0), and 42 (67%) were men. The physical component summary at 2 years was 52.4 (SD 6.3) in the TSF group and 53.3 (SD 8.0) in the IMN group ( P = 0.35). There were modest differences in the other SF-36 scores during the follow-up period. Up to and including 12 months, the TSF group had less knee pain [at 12 months: VAS 0.5 (SD 1.2) vs. VAS 2.4 (SD 2.2; P < 0.001)], but this was not statistically significant at 24 months [VAS 0.7 (SD 1.4) vs. VAS 1.5 (SD 2.0; P = 0.11)]. Superficial skin infections were more frequent in the TSF group [22 (71%) vs. 4 (13%); P < 0.001]. The number of other complications was similar between the groups. Conclusions: Both TSF and IMN provided good clinical results. TSF had more pin-track infections but less knee pain the first year. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Abstract : Supplemental Digital Content is Available in the Text. … (more)
- Is Part Of:
- Journal of orthopaedic trauma. Volume 34:Issue 11(2020)
- Journal:
- Journal of orthopaedic trauma
- Issue:
- Volume 34:Issue 11(2020)
- Issue Display:
- Volume 34, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 11
- Issue Sort Value:
- 2020-0034-0011-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11
- Subjects:
- tibia -- diaphysis -- fracture -- intramedullary nail -- ring fixator -- surgical treatment
Orthopedics -- Periodicals
Wounds and injuries -- Periodicals
Orthopedics -- Periodicals
Wounds and Injuries -- therapy -- Periodicals
Periodicals
617.47044 - Journal URLs:
- http://journals.lww.com/jorthotrauma/pages/default.aspx ↗
http://www.jorthotrauma.com ↗
http://cufts2.lib.sfu.ca/CJDB/BVAS/journal/149202 ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00005131-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BOT.0000000000001802 ↗
- Languages:
- English
- ISSNs:
- 0890-5339
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5027.675000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15160.xml