Comparison of image quality in chest, hip and pelvis examinations between mobile equipment in nursing homes and static indirect radiography equipment in the hospital. Issue 2 (May 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of image quality in chest, hip and pelvis examinations between mobile equipment in nursing homes and static indirect radiography equipment in the hospital. Issue 2 (May 2020)
- Main Title:
- Comparison of image quality in chest, hip and pelvis examinations between mobile equipment in nursing homes and static indirect radiography equipment in the hospital
- Authors:
- Precht, H.
Hansen, D.L.
Ring-Pedersen, B.M.
Møller Hansen, L.F.
Waaler, D.
Tingberg, A.
Midtgaard, M.
Jensen Ohlsen, M.G.
Juhl Hankelbjerg, S.T.
Ravn, P.
Jensen, I.E.
Christensen, J.K.
Blackburn Andersen, P.A. - Abstract:
- Abstract: Introduction: A hospital environment can be a significant burden and a health risk especially for dementia patients. Mobile x-ray equipment (ME) is used to enable imaging of these patients at home. The aim was to compare image quality (IQ) of chest, hip and pelvis images from ME to the stationary equipment (SE) used in a hospital department. Methods: We analysed examinations of the chest (n = 20), hip (n = 64) and pelvis (n = 32). Images were equally obtained from each setting of ME and SE. All images were graded using Visual Grading Analysis (VGA) by three radiographers (hip and pelvis) and three radiologists (chest). Technical IQ assessment was done by 80 additional images of a Contrast-Detail Radiography phantom (CDRAD). Results: All chest images were approved for diagnostic use, as well as the hip AP and pelvis images from SE. 'Approved proportion of ME images was for HIP antero-posterior (AP) and pelvis, 78% [95% CI: 52–94%] and 81% [95% CI: 54–96%] respectively. Hip axial had an overall low, but not significant different approval rate. Ordered logistic regression indicated higher IQ of HIP AP and pelvic images from SE. This contrasts that the CDRAD substudy indicated better IQ, expressed as IQFinv, from ME. Conclusion: The VGA showed higher IQ for the SE system, while the CDRAD showed higher IQ for the ME system. Implications for practice: Dementia patients can be examined at their home if the acquisition is optimised according to image quality in conjunct toAbstract: Introduction: A hospital environment can be a significant burden and a health risk especially for dementia patients. Mobile x-ray equipment (ME) is used to enable imaging of these patients at home. The aim was to compare image quality (IQ) of chest, hip and pelvis images from ME to the stationary equipment (SE) used in a hospital department. Methods: We analysed examinations of the chest (n = 20), hip (n = 64) and pelvis (n = 32). Images were equally obtained from each setting of ME and SE. All images were graded using Visual Grading Analysis (VGA) by three radiographers (hip and pelvis) and three radiologists (chest). Technical IQ assessment was done by 80 additional images of a Contrast-Detail Radiography phantom (CDRAD). Results: All chest images were approved for diagnostic use, as well as the hip AP and pelvis images from SE. 'Approved proportion of ME images was for HIP antero-posterior (AP) and pelvis, 78% [95% CI: 52–94%] and 81% [95% CI: 54–96%] respectively. Hip axial had an overall low, but not significant different approval rate. Ordered logistic regression indicated higher IQ of HIP AP and pelvic images from SE. This contrasts that the CDRAD substudy indicated better IQ, expressed as IQFinv, from ME. Conclusion: The VGA showed higher IQ for the SE system, while the CDRAD showed higher IQ for the ME system. Implications for practice: Dementia patients can be examined at their home if the acquisition is optimised according to image quality in conjunct to radiation dose. Performing imaging out of the hospital and coordinating the patients' further treatment are new work areas for radiographers and requires excellent communication skills. … (more)
- Is Part Of:
- Radiography. Volume 26:Issue 2(2020)
- Journal:
- Radiography
- Issue:
- Volume 26:Issue 2(2020)
- Issue Display:
- Volume 26, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 26
- Issue:
- 2
- Issue Sort Value:
- 2020-0026-0002-0000
- Page Start:
- e31
- Page End:
- e37
- Publication Date:
- 2020-05
- Subjects:
- Image quality -- Indirect digital radiography -- Mobile radiography -- Nursing homes
Diagnostic imaging -- Periodicals
Radiotherapy -- Periodicals
Cancer -- Radiotherapy -- Periodicals
Diagnostic Imaging -- Periodicals
Neoplasms -- Periodicals
Radiotherapy -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Radiothérapie -- Périodiques
Cancer -- Radiothérapie -- Périodiques
Electronic journals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10788174 ↗
http://www.radiographyonline.com/ ↗
http://www.harcourt-international.com/journals ↗
http://www.idealibrary.com/links/toc/radi/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10788174 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10788174 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiography/ ↗ - DOI:
- 10.1016/j.radi.2019.10.004 ↗
- Languages:
- English
- ISSNs:
- 1078-8174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7237.001000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15155.xml