Similar patient positioning: A key factor in follow-up studies when using model-based radiostereometric analysis of the hip. Issue 2 (May 2020)
- Record Type:
- Journal Article
- Title:
- Similar patient positioning: A key factor in follow-up studies when using model-based radiostereometric analysis of the hip. Issue 2 (May 2020)
- Main Title:
- Similar patient positioning: A key factor in follow-up studies when using model-based radiostereometric analysis of the hip
- Authors:
- Lindgren, L.
Jørgensen, P.B.
Mørup, R.M.S.
Jensen, M.
Rømer, L.
Kaptein, B.
Stilling, M. - Abstract:
- Abstract: Introduction: Despite protocols, patients are not positioned exactly alike at radiostereometric (RSA) follow-up examinations, and it is unknown how much variation is tolerable. We report precision for optimal and extreme position differences from a phantom hip-study, and clinical precision of hip-RSA. Methods: A femoral stem with 3 bead-towers was fixed in a saw bone with bone-markers (phantom), and series of RSA examinations within optimal (5 × 5 cm and 5°) and extreme (20 × 30 cm and 30°) phantom positions were obtained. Double-examination RSA of 12 patients with the same femoral stem type were analyzed. Both model-based (CAD) and marker-based (MM) analysis was used. Precision was reported as standard deviation of differences. Results: Precision for translations in the optimal and extreme phantom position were below 0.06 mm and 0.02 mm for MM analysis, and below 0.05 mm and 0.18 mm for CAD analysis, respectively. Precision for rotations in the optimal and extreme phantom rotation were below 0.18° and 0.26° for MM analysis, and below 0.34° and 0.52° for CAD analysis, respectively. Clinical precision was 0.29 mm and 0.44° for MM analysis, and 0.40 mm and 1.59° for CAD analysis. Conclusion: Extreme differences in patient position during RSA examination negatively affects precision, and CAD model-analysis was more sensitive than MM analysis. Longitudinal translation and rotation about the long stem-axis are the effect parameters which are most affected by positionAbstract: Introduction: Despite protocols, patients are not positioned exactly alike at radiostereometric (RSA) follow-up examinations, and it is unknown how much variation is tolerable. We report precision for optimal and extreme position differences from a phantom hip-study, and clinical precision of hip-RSA. Methods: A femoral stem with 3 bead-towers was fixed in a saw bone with bone-markers (phantom), and series of RSA examinations within optimal (5 × 5 cm and 5°) and extreme (20 × 30 cm and 30°) phantom positions were obtained. Double-examination RSA of 12 patients with the same femoral stem type were analyzed. Both model-based (CAD) and marker-based (MM) analysis was used. Precision was reported as standard deviation of differences. Results: Precision for translations in the optimal and extreme phantom position were below 0.06 mm and 0.02 mm for MM analysis, and below 0.05 mm and 0.18 mm for CAD analysis, respectively. Precision for rotations in the optimal and extreme phantom rotation were below 0.18° and 0.26° for MM analysis, and below 0.34° and 0.52° for CAD analysis, respectively. Clinical precision was 0.29 mm and 0.44° for MM analysis, and 0.40 mm and 1.59° for CAD analysis. Conclusion: Extreme differences in patient position during RSA examination negatively affects precision, and CAD model-analysis was more sensitive than MM analysis. Longitudinal translation and rotation about the long stem-axis are the effect parameters which are most affected by position and rotation changes, and also the best indicators of implant loosening. Implications for practice: Based on our research, we recommend that similar patient positioning between follow-up RSA examinations is debated and prioritized. … (more)
- Is Part Of:
- Radiography. Volume 26:Issue 2(2020)
- Journal:
- Radiography
- Issue:
- Volume 26:Issue 2(2020)
- Issue Display:
- Volume 26, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 26
- Issue:
- 2
- Issue Sort Value:
- 2020-0026-0002-0000
- Page Start:
- e45
- Page End:
- e51
- Publication Date:
- 2020-05
- Subjects:
- Radiostereometric analysis -- RSA -- Total hip arthroplasty -- Precision -- Hip stem
Diagnostic imaging -- Periodicals
Radiotherapy -- Periodicals
Cancer -- Radiotherapy -- Periodicals
Diagnostic Imaging -- Periodicals
Neoplasms -- Periodicals
Radiotherapy -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Radiothérapie -- Périodiques
Cancer -- Radiothérapie -- Périodiques
Electronic journals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10788174 ↗
http://www.radiographyonline.com/ ↗
http://www.harcourt-international.com/journals ↗
http://www.idealibrary.com/links/toc/radi/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10788174 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10788174 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiography/ ↗ - DOI:
- 10.1016/j.radi.2019.10.009 ↗
- Languages:
- English
- ISSNs:
- 1078-8174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7237.001000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15155.xml