Atrial fibrillation detection by the subcutaneous defibrillator: real-world clinical performances and implications from a multicentre study. Issue 11 (23rd August 2020)
- Record Type:
- Journal Article
- Title:
- Atrial fibrillation detection by the subcutaneous defibrillator: real-world clinical performances and implications from a multicentre study. Issue 11 (23rd August 2020)
- Main Title:
- Atrial fibrillation detection by the subcutaneous defibrillator: real-world clinical performances and implications from a multicentre study
- Authors:
- Ollitrault, Pierre
Jacon, Peggy
Auquier, Nathanaël
Champ-Rigot, Laure
Ben Kilani, Mouna
Vandevelde, Florence
Pellissier, Arnaud
Ferchaud, Virginie
Legallois, Damien
Defaye, Pascal
Anselme, Frédéric
Milliez, Paul - Abstract:
- Abstract: Aims: No data exist concerning the clinical performances of the subcutaneous implantable cardioverter-defibrillator (S-ICD) atrial fibrillation (AF) detection algorithm. We aimed to study the performances and implications of the latter in a 'real-world' setting. Methods and results: Between July 2017 and August 2019, 155 consecutive S-ICD recipients were included. Endpoint of the study was the incidence of de novo or recurrent AF using a combined on-site and remote-monitoring follow-up approach. After a mean follow-up of 13 ± 8 months, 2531 AF alerts were generated for 55 patients. A blinded analysis of the 1950 subcutaneous electrocardiograms available was performed. Among them 47% were true AF, 23% were premature atrial contractions or non-sustained AF, 29% were premature ventricular contractions or non-sustained ventricular tachycardia, and 1% were misdetection. Fourteen percent (21/155) patients had at least one correct diagnosis of AF by the S-ICD algorithm. One patient presented symptomatic paroxysmal AF not diagnosed by the S-ICD algorithm (false negative patient). Patient-based sensitivity, specificity, positive, and negative predictive values were respectively 95%, 74%, 38%, and 99%. Among patients with at least one correct diagnosis of AF, 38% (8/21) had subsequent clinical implications (anticoagulation initiation or rhythm control therapies). Conclusion: The S-ICD AF detection algorithm yields a high sensitivity for AF diagnosis. Low specificity andAbstract: Aims: No data exist concerning the clinical performances of the subcutaneous implantable cardioverter-defibrillator (S-ICD) atrial fibrillation (AF) detection algorithm. We aimed to study the performances and implications of the latter in a 'real-world' setting. Methods and results: Between July 2017 and August 2019, 155 consecutive S-ICD recipients were included. Endpoint of the study was the incidence of de novo or recurrent AF using a combined on-site and remote-monitoring follow-up approach. After a mean follow-up of 13 ± 8 months, 2531 AF alerts were generated for 55 patients. A blinded analysis of the 1950 subcutaneous electrocardiograms available was performed. Among them 47% were true AF, 23% were premature atrial contractions or non-sustained AF, 29% were premature ventricular contractions or non-sustained ventricular tachycardia, and 1% were misdetection. Fourteen percent (21/155) patients had at least one correct diagnosis of AF by the S-ICD algorithm. One patient presented symptomatic paroxysmal AF not diagnosed by the S-ICD algorithm (false negative patient). Patient-based sensitivity, specificity, positive, and negative predictive values were respectively 95%, 74%, 38%, and 99%. Among patients with at least one correct diagnosis of AF, 38% (8/21) had subsequent clinical implications (anticoagulation initiation or rhythm control therapies). Conclusion: The S-ICD AF detection algorithm yields a high sensitivity for AF diagnosis. Low specificity and positive predictive value contribute to a high remote monitoring-notification workload and underline the necessity of a manual analysis. Atrial fibrillation diagnosis by the S-ICD AF detection algorithm might lead to significant therapeutic adjustments. … (more)
- Is Part Of:
- Europace. Volume 22:Issue 11(2020)
- Journal:
- Europace
- Issue:
- Volume 22:Issue 11(2020)
- Issue Display:
- Volume 22, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 11
- Issue Sort Value:
- 2020-0022-0011-0000
- Page Start:
- 1628
- Page End:
- 1634
- Publication Date:
- 2020-08-23
- Subjects:
- Atrial fibrillation -- Subcutaneous defibrillator -- Algorithm -- Sensitivity
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa184 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15136.xml