Significant decrease in lipid core burden index following balloon dilation was associated with the leakage of cholesterol crystals in a patient: a case report. Issue 4 (17th June 2020)
- Record Type:
- Journal Article
- Title:
- Significant decrease in lipid core burden index following balloon dilation was associated with the leakage of cholesterol crystals in a patient: a case report. Issue 4 (17th June 2020)
- Main Title:
- Significant decrease in lipid core burden index following balloon dilation was associated with the leakage of cholesterol crystals in a patient: a case report
- Authors:
- Moriya, Soshi
Isoda, Kikuo
Dohi, Tomotaka
Okazaki, Shinya - Editors:
- Liga, Riccardo
Didier, Romain
Dias, Andre
Camm, Christian Fielder
Green, Peregrine - Abstract:
- Abstract: Background: Near-infrared spectroscopy (NIRS) has been used for analysis the composition of the atherosclerotic plaque in coronary arteries. However, meaning of significant decrease in max lipid core burden index at 4 mm (max LCBI4mm ) during percutaneous coronary intervention (PCI) is poorly understood. Case summary: A 64-year-old male with unstable angina underwent coronary angiography, which demonstrated a hazy tight culprit lesion in the mid-right coronary artery. Pre-intervention NIRS–intravascular ultrasound (NIRS–IVUS) and chemogram showed plaque with high lipid burden at the culprit lesion. Then, we used a distal protection device before PCI because of high max LCBI4mm in the lesion. After pre-dilation with a scoring balloon, repeat NIRS–IVUS interrogation revealed an almost complete disappearance of the yellow signal and decrease in max LCBI4mm (from 537 to 44) significantly, suggesting decrease in the lipid content of the plaque. Finally, a drug-eluting stent deployment followed by inflation of a non-compliant balloon led to an excellent result. After PCI, we detected trapped large amounts of debris on retrieval of the filter. Pathological diagnosis confirmed that trapped material was lipid-rich plaque including cholesterol crystals. Discussion: This is the first report directly demonstrated that significant decrease in max LCBI4mm at culprit lesion should be associated with the leakage of cholesterol crystals from lipid-rich plaque during PCI in theAbstract: Background: Near-infrared spectroscopy (NIRS) has been used for analysis the composition of the atherosclerotic plaque in coronary arteries. However, meaning of significant decrease in max lipid core burden index at 4 mm (max LCBI4mm ) during percutaneous coronary intervention (PCI) is poorly understood. Case summary: A 64-year-old male with unstable angina underwent coronary angiography, which demonstrated a hazy tight culprit lesion in the mid-right coronary artery. Pre-intervention NIRS–intravascular ultrasound (NIRS–IVUS) and chemogram showed plaque with high lipid burden at the culprit lesion. Then, we used a distal protection device before PCI because of high max LCBI4mm in the lesion. After pre-dilation with a scoring balloon, repeat NIRS–IVUS interrogation revealed an almost complete disappearance of the yellow signal and decrease in max LCBI4mm (from 537 to 44) significantly, suggesting decrease in the lipid content of the plaque. Finally, a drug-eluting stent deployment followed by inflation of a non-compliant balloon led to an excellent result. After PCI, we detected trapped large amounts of debris on retrieval of the filter. Pathological diagnosis confirmed that trapped material was lipid-rich plaque including cholesterol crystals. Discussion: This is the first report directly demonstrated that significant decrease in max LCBI4mm at culprit lesion should be associated with the leakage of cholesterol crystals from lipid-rich plaque during PCI in the clinical patient. … (more)
- Is Part Of:
- European heart journal. Volume 4:Issue 4(2020)
- Journal:
- European heart journal
- Issue:
- Volume 4:Issue 4(2020)
- Issue Display:
- Volume 4, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 4
- Issue:
- 4
- Issue Sort Value:
- 2020-0004-0004-0000
- Page Start:
- 1
- Page End:
- 5
- Publication Date:
- 2020-06-17
- Subjects:
- Case report -- Percutaneous coronary intervention -- Near-infrared spectroscopy -- Histopathological study
Cardiology -- Periodicals
Cardiology -- Case studies -- Periodicals
Heart -- Diseases -- Periodicals
Heart -- Diseases -- Case studies -- Periodicals
616.12 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/ehjcr/ ↗ - DOI:
- 10.1093/ehjcr/ytaa148 ↗
- Languages:
- English
- ISSNs:
- 2514-2119
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15147.xml