PSIX-27 Evaluation of real-time ultrasound to predict pre-harvest market endpoints in serial slaughtered British x Continental steers administered an E2+TBA implant treatment vs non-implanted controls. (30th November 2020)
- Record Type:
- Journal Article
- Title:
- PSIX-27 Evaluation of real-time ultrasound to predict pre-harvest market endpoints in serial slaughtered British x Continental steers administered an E2+TBA implant treatment vs non-implanted controls. (30th November 2020)
- Main Title:
- PSIX-27 Evaluation of real-time ultrasound to predict pre-harvest market endpoints in serial slaughtered British x Continental steers administered an E2+TBA implant treatment vs non-implanted controls
- Authors:
- Grimes, Becca B
Kirkpatrick, Tylo J
Tennant, Travis
Lawrence, Ty
Cooper, Kimberly B
Francis, Forest L
Pillmore, Sierra L
Wesley, Kaitlyn R
Perkins, Tommy L
Riberio, Flavio
Garrison, Max D
Nichols, Wade
Hutcheson, John - Abstract:
- Abstract: Steers (n = 80; initial BW 271 ± 99) were serially scanned at 42-d intervals during a 378-d feeding period using an Aloka 500 device by a certified Ultrasound Guidelines Council (UGC) technician using real-time ultrasound. This included 10 separate ultrasound scanning sessions following the initial weight and ultrasound data taken on day minus 7 (one week prior to initial start date). Steers were randomly assigned to implant treatment (either implanted with Revalor XS or not) at day -7. Cattle were weighed and scanned for 12 th -rib fat thickness (FTU), 12 th -rib longissimus muscle area (LMAU), percentage intramuscular fat (%FATU), and rump fat thickness (RFU) to determine the ability of ultrasound to predict carcass grading outcomes at harvest. Scans were processed by CUP Lab technicians. Eight steers were harvested each 42 days. Carcasses were assessed 48h after harvest to determine 12 th -rib fat thickness (FTC), 12 th -rib longissimus muscle area (LMAC), and marbling score (MARB). Data were analyzed via Pearson correlation and linear regression to determine the relationship of ultrasound measures to carcass outcomes. Positive correlations (P < 0.01) between ultrasound measures taken the day before harvest and carcass measurements indicated strong relationships between FTU and FTC (r = 0.91), LMAU and LMAC (r = 0.93), and moderately strong relationships between %FATU and MARB (r = 0.76). Prediction equations were generated to estimate FTC = .0088 + (1.02585 xAbstract: Steers (n = 80; initial BW 271 ± 99) were serially scanned at 42-d intervals during a 378-d feeding period using an Aloka 500 device by a certified Ultrasound Guidelines Council (UGC) technician using real-time ultrasound. This included 10 separate ultrasound scanning sessions following the initial weight and ultrasound data taken on day minus 7 (one week prior to initial start date). Steers were randomly assigned to implant treatment (either implanted with Revalor XS or not) at day -7. Cattle were weighed and scanned for 12 th -rib fat thickness (FTU), 12 th -rib longissimus muscle area (LMAU), percentage intramuscular fat (%FATU), and rump fat thickness (RFU) to determine the ability of ultrasound to predict carcass grading outcomes at harvest. Scans were processed by CUP Lab technicians. Eight steers were harvested each 42 days. Carcasses were assessed 48h after harvest to determine 12 th -rib fat thickness (FTC), 12 th -rib longissimus muscle area (LMAC), and marbling score (MARB). Data were analyzed via Pearson correlation and linear regression to determine the relationship of ultrasound measures to carcass outcomes. Positive correlations (P < 0.01) between ultrasound measures taken the day before harvest and carcass measurements indicated strong relationships between FTU and FTC (r = 0.91), LMAU and LMAC (r = 0.93), and moderately strong relationships between %FATU and MARB (r = 0.76). Prediction equations were generated to estimate FTC = .0088 + (1.02585 x FTU), LMAC = 16.29720 + (0.77197 x LMAU) and MARB = 19.87510 + (5.19832 x %FATU). Results suggest real-time ultrasound data provides an effective tool to estimate carcass outcomes pre-harvest. … (more)
- Is Part Of:
- Journal of animal science. Volume 98(2020)Supplement 4
- Journal:
- Journal of animal science
- Issue:
- Volume 98(2020)Supplement 4
- Issue Display:
- Volume 98, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 98
- Issue:
- 4
- Issue Sort Value:
- 2020-0098-0004-0000
- Page Start:
- 331
- Page End:
- 332
- Publication Date:
- 2020-11-30
- Subjects:
- Implant -- Steer -- Ultrasound
Livestock -- Periodicals
Livestock
Electronic journals
Periodicals
636.005 - Journal URLs:
- https://dl.sciencesocieties.org/publications/jas/index ↗
http://www.asas.org/jas/ ↗
https://academic.oup.com/jas ↗
http://www.oxfordjournals.org/ ↗ - DOI:
- 10.1093/jas/skaa278.589 ↗
- Languages:
- English
- ISSNs:
- 0021-8812
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15127.xml