0587 Convenience vs Accuracy: Negative Predictability of the Home Sleep Test in Clinical Practice. (27th May 2020)
- Record Type:
- Journal Article
- Title:
- 0587 Convenience vs Accuracy: Negative Predictability of the Home Sleep Test in Clinical Practice. (27th May 2020)
- Main Title:
- 0587 Convenience vs Accuracy: Negative Predictability of the Home Sleep Test in Clinical Practice
- Authors:
- Morse, C D
Meissner, S
Kodali, L - Abstract:
- Abstract: Introduction: Sleep apnea is a serious disorder associated with numerous health conditions. In clinical practice, providers order screening home sleep testing (HST) for obstructive sleep apnea (OSA); however, there is limited research about the negative predictive value (NPV) and false negative rate of this test. Providers may not understand HST limitations; therefore, what is the NPV and false negative rate in clinical practice? Methods: A retrospective study of non-diagnostic HST is conducted in a Northeastern US rural community sleep clinic. The study population includes adult patients ≥ 18 years old who underwent HST from 2016-2019. The non-diagnostic HST result is compared to the gold standard, the patient's nocturnal polysomnogram (NPSG). The results provide the NPV (true negative/total) and false negative (true positive/total) for the non-diagnostic HST. Results: We identified 211 potential patients with a mean age of 43 years, of which 67% were female. Of those, 85% (n=179) underwent NPSG, with the others declining/delaying testing or lost to follow up. The non-diagnostic HST showed 15.6% NPV for no apnea using AHI<5 and 8.4% NPV using respiratory disturbance index (tRDI)<5. The false negative rate for AHI/tRDI was 84.4% and 91.6%, respectively. The AHI for positive tests ranged from 5-89 per hour (mean AHI 14.9/tRDI 16/hour), of which OSA was identified with an elevated AHI ( ≥ 5) ranging from 54.2% mild, 21.8% moderate, and 8.4% severe. Conclusion: TheAbstract: Introduction: Sleep apnea is a serious disorder associated with numerous health conditions. In clinical practice, providers order screening home sleep testing (HST) for obstructive sleep apnea (OSA); however, there is limited research about the negative predictive value (NPV) and false negative rate of this test. Providers may not understand HST limitations; therefore, what is the NPV and false negative rate in clinical practice? Methods: A retrospective study of non-diagnostic HST is conducted in a Northeastern US rural community sleep clinic. The study population includes adult patients ≥ 18 years old who underwent HST from 2016-2019. The non-diagnostic HST result is compared to the gold standard, the patient's nocturnal polysomnogram (NPSG). The results provide the NPV (true negative/total) and false negative (true positive/total) for the non-diagnostic HST. Results: We identified 211 potential patients with a mean age of 43 years, of which 67% were female. Of those, 85% (n=179) underwent NPSG, with the others declining/delaying testing or lost to follow up. The non-diagnostic HST showed 15.6% NPV for no apnea using AHI<5 and 8.4% NPV using respiratory disturbance index (tRDI)<5. The false negative rate for AHI/tRDI was 84.4% and 91.6%, respectively. The AHI for positive tests ranged from 5-89 per hour (mean AHI 14.9/tRDI 16/hour), of which OSA was identified with an elevated AHI ( ≥ 5) ranging from 54.2% mild, 21.8% moderate, and 8.4% severe. Conclusion: The high false negative rate of the HST is alarming. Some providers and patients may forgo NPSG after non-diagnostic HST due to a lack of understanding for the HST's limitations. Knowing that the non-diagnostic HST is a very poor predictor of no sleep apnea will help providers advise patients appropriately for the necessity of the NPSG. The subsequent NPSG provides an accurate diagnosis and, therefore, an informed decision about pursuing or eschewing sleep apnea treatment. Support: none … (more)
- Is Part Of:
- Sleep. Volume 43(2020)Supplement 1
- Journal:
- Sleep
- Issue:
- Volume 43(2020)Supplement 1
- Issue Display:
- Volume 43, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 43
- Issue:
- 1
- Issue Sort Value:
- 2020-0043-0001-0000
- Page Start:
- A225
- Page End:
- A225
- Publication Date:
- 2020-05-27
- Subjects:
- Sleep -- Physiological aspects -- Periodicals
Sleep disorders -- Periodicals
Sommeil -- Aspect physiologique -- Périodiques
Sommeil, Troubles du -- Périodiques
Sleep disorders
Sleep -- Physiological aspects
Sleep -- physiological aspects
Sleep Wake Disorders
Psychophysiology
Electronic journals
Periodicals
616.8498 - Journal URLs:
- http://bibpurl.oclc.org/web/21399 ↗
http://www.journalsleep.org/ ↗
https://academic.oup.com/sleep ↗
http://www.oxfordjournals.org/ ↗
http://www.pubmedcentral.nih.gov/tocrender.fcgi?journal=369&action=archive ↗ - DOI:
- 10.1093/sleep/zsaa056.584 ↗
- Languages:
- English
- ISSNs:
- 0161-8105
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15131.xml