Comparison of two analytical platforms for blood‐based surrogate biomarkers of amyloid pathology: Biomarkers (non‐neuroimaging) / plasma/serum/urine biomarkers. (7th December 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of two analytical platforms for blood‐based surrogate biomarkers of amyloid pathology: Biomarkers (non‐neuroimaging) / plasma/serum/urine biomarkers. (7th December 2020)
- Main Title:
- Comparison of two analytical platforms for blood‐based surrogate biomarkers of amyloid pathology
- Authors:
- De Meyer, Steffi
Schaeverbeke, Jolien
Gille, Benjamin
Verberk, Inge M.W.
Luckett, Emma Susanne
Thijssen, Elisabeth H.
Gabel, Silvy
Mauroo, Kimberley
Bruffaerts, Rose
Stoops, Erik
Vanderstichele, Hugo Marcel
Teunissen, Charlotte E.
Vandenberghe, Rik
Poesen, Koen - Abstract:
- Abstract: Background: Formation of amyloid plaques and fibrillary tau tangles in brain are key pathological hallmarks in Alzheimer's disease (AD). Surrogate biomarkers of these hallmarks have been established in CSF. However, a less invasive sample source would simplify the recruitment and the follow‐up of response in clinical trials targeting the pathological hallmarks in AD. We assessed the performances of two analytical platforms for plasma beta‐amyloid (Aβ) species and total tau (t‐tau) as surrogates of amyloid‐PET status. Methods: Plasma Aβ1‐42 and Aβ1‐40 were quantified in cognitively healthy controls (n=160, age[mean]=69, 46% female) and amnestic MCI (aMCI) patients (n=41, age[mean]=71, 43% female) by i) the Simoa Amyblood platform (Amsterdam UMC and ADx NeuroSciences) and ii) an ELISA platform (Euroimmun, Lubeck, Germany) employing identical antibody pairs. Plasma t‐tau was quantified with a prototype ELISA (ADx NeuroSciences). The same biomarkers were also measured in CSF (ELISA [Euroimmun]). Controls underwent [ 18 F]‐flutemetamol PET and aMCI patients received [ 18 F]‐florbetaben PET (SUVRcomp cut‐off for amyloid positivity=1.38 and 1.29, respectively). Spearman correlations between CSF and plasma biomarkers were calculated and the performance of plasma biomarkers to identify amyloid PET positivity was determined through ROC analysis. Bonferroni correction adjusted for multiple comparisons. Results: For ELISA, the strongest correlations were found among amyloidAbstract: Background: Formation of amyloid plaques and fibrillary tau tangles in brain are key pathological hallmarks in Alzheimer's disease (AD). Surrogate biomarkers of these hallmarks have been established in CSF. However, a less invasive sample source would simplify the recruitment and the follow‐up of response in clinical trials targeting the pathological hallmarks in AD. We assessed the performances of two analytical platforms for plasma beta‐amyloid (Aβ) species and total tau (t‐tau) as surrogates of amyloid‐PET status. Methods: Plasma Aβ1‐42 and Aβ1‐40 were quantified in cognitively healthy controls (n=160, age[mean]=69, 46% female) and amnestic MCI (aMCI) patients (n=41, age[mean]=71, 43% female) by i) the Simoa Amyblood platform (Amsterdam UMC and ADx NeuroSciences) and ii) an ELISA platform (Euroimmun, Lubeck, Germany) employing identical antibody pairs. Plasma t‐tau was quantified with a prototype ELISA (ADx NeuroSciences). The same biomarkers were also measured in CSF (ELISA [Euroimmun]). Controls underwent [ 18 F]‐flutemetamol PET and aMCI patients received [ 18 F]‐florbetaben PET (SUVRcomp cut‐off for amyloid positivity=1.38 and 1.29, respectively). Spearman correlations between CSF and plasma biomarkers were calculated and the performance of plasma biomarkers to identify amyloid PET positivity was determined through ROC analysis. Bonferroni correction adjusted for multiple comparisons. Results: For ELISA, the strongest correlations were found among amyloid biomarker ratios between plasma and CSF within the aMCI cohort (r=0.6561‐0.8123, p<0.0023); most of these correlations were also present in controls, albeit weaker (r=0.4308‐0.5498, p<0.0078). Using Amyblood, correlations were weaker than for ELISA, most not surviving Bonferroni correction (Table 1). All plasma biomarker ratios could differentiate between amyloid‐PET positive and amyloid‐PET negative subjects in both cohorts (AUC[range]=0.719‐0.876, p<0.0001). Plasma t‐tau identified amyloid positivity only in the aMCI cohort (AUC[range]=0.818, p<0.0001), while plasma Aβ1‐42 could do so only in controls (AUC[range]=0.676‐0.679, p<0.0027). Within the aMCI cohort, Aβ1‐42/Aβ1‐40 performed better than Aβ1‐42 when measured with Amyblood (p=0.0064). No differences in performances were observed between platforms for any biomarker (p>0.543) (Table2). Logistic regression analysis including age, gender and APOEε4 as covariates did not significantly improve performances. Conclusion: Measuring amyloid species with blood‐based immunoassays renders good performance to assess amyloid PET status, especially in aMCI. To this end, Amyblood did not outperform ELISA. … (more)
- Is Part Of:
- Alzheimer's & dementia. Volume 16(2020)Supplement 4
- Journal:
- Alzheimer's & dementia
- Issue:
- Volume 16(2020)Supplement 4
- Issue Display:
- Volume 16, Issue 4 (2020)
- Year:
- 2020
- Volume:
- 16
- Issue:
- 4
- Issue Sort Value:
- 2020-0016-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-12-07
- Subjects:
- Alzheimer's disease -- Periodicals
Alzheimer Disease -- Periodicals
Dementia -- Periodicals
Démence
Maladie d'Alzheimer
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.83 - Journal URLs:
- http://www.sciencedirect.com/science/journal/15525260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1002/alz.045110 ↗
- Languages:
- English
- ISSNs:
- 1552-5260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0806.255333
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15120.xml