Homogeneity of neutron transmission imaging over a large sensitive area with a four-channel superconducting detector. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Homogeneity of neutron transmission imaging over a large sensitive area with a four-channel superconducting detector. (25th November 2020)
- Main Title:
- Homogeneity of neutron transmission imaging over a large sensitive area with a four-channel superconducting detector
- Authors:
- Vu, The Dang
Shishido, Hiroaki
Kojima, Kenji M
Koyama, Tomio
Oikawa, Kenichi
Harada, Masahide
Miyajima, Shigeyuki
Oku, Takayuki
Soyama, Kazuhiko
Aizawa, Kazuya
Hidaka, Mutsuo
Suzuki, Soh Y
Tanaka, Manobu M
Malins, Alex
Machida, Masahiko
Ishida, Takekazu - Abstract:
- Abstract: We previously proposed a method to detect neutrons by using a current-biased kinetic inductance detector (CB-KID), where neutrons are converted into charged particles using a 10 B conversion layer. The charged particles are detected based on local changes in kinetic inductance of X and Y superconducting meanderlines under a modest DC bias current. The system uses a delay-line method to locate the positions of neutron- 10 B reactions by acquiring the four arrival timestamps of signals that propagate from hot spots created by a passing charged particle to the end electrodes of the meanderlines. Unlike conventional multi-pixel imaging systems, the CB-KID system performs high spatial resolution imaging over a 15 mm × 15 mm sensitive area using only four channel readouts. Given the large sensitive area, it is important to check the spatial homogeneity and linearity of detected neutron positions when imaging with CB-KID. To this end we imaged a pattern of 10 B dot absorbers with a precise dot pitch to investigate the spatial homogeneity of the detector. We confirmed the spatial homogeneity of detected dot positions based on the distribution of measured dot pitches across the sensitive area of the detector. We demonstrate potential applications of the system by taking a clear transmission image of tiny metallic screws and nuts and a ladybug. The image was useful for characterizing the ladybug noninvasively. Detection efficiencies were low when the detector was operated atAbstract: We previously proposed a method to detect neutrons by using a current-biased kinetic inductance detector (CB-KID), where neutrons are converted into charged particles using a 10 B conversion layer. The charged particles are detected based on local changes in kinetic inductance of X and Y superconducting meanderlines under a modest DC bias current. The system uses a delay-line method to locate the positions of neutron- 10 B reactions by acquiring the four arrival timestamps of signals that propagate from hot spots created by a passing charged particle to the end electrodes of the meanderlines. Unlike conventional multi-pixel imaging systems, the CB-KID system performs high spatial resolution imaging over a 15 mm × 15 mm sensitive area using only four channel readouts. Given the large sensitive area, it is important to check the spatial homogeneity and linearity of detected neutron positions when imaging with CB-KID. To this end we imaged a pattern of 10 B dot absorbers with a precise dot pitch to investigate the spatial homogeneity of the detector. We confirmed the spatial homogeneity of detected dot positions based on the distribution of measured dot pitches across the sensitive area of the detector. We demonstrate potential applications of the system by taking a clear transmission image of tiny metallic screws and nuts and a ladybug. The image was useful for characterizing the ladybug noninvasively. Detection efficiencies were low when the detector was operated at 4 K, so we plan to explore raising the operating temperature towards the critical temperature of the detector as a means to improve counting rates. … (more)
- Is Part Of:
- Superconductor science & technology. Volume 34:Number 1(2021)
- Journal:
- Superconductor science & technology
- Issue:
- Volume 34:Number 1(2021)
- Issue Display:
- Volume 34, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 34
- Issue:
- 1
- Issue Sort Value:
- 2021-0034-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-11-25
- Subjects:
- neutron detector -- homogeneity of imaging -- linearity -- current-biased kinetic inductance detector
Superconductivity -- Periodicals
Superconductors -- Periodicals
537.623 - Journal URLs:
- http://iopscience.iop.org/0953-2048 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6668/abc2af ↗
- Languages:
- English
- ISSNs:
- 0953-2048
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15108.xml