Clinical experience of biliary T tube of immobilization of peri-pin membrane in tibial Gustilo III fracture treated with vacuum sealant drainage combined with an external fixator. Issue 43 (23rd October 2020)
- Record Type:
- Journal Article
- Title:
- Clinical experience of biliary T tube of immobilization of peri-pin membrane in tibial Gustilo III fracture treated with vacuum sealant drainage combined with an external fixator. Issue 43 (23rd October 2020)
- Main Title:
- Clinical experience of biliary T tube of immobilization of peri-pin membrane in tibial Gustilo III fracture treated with vacuum sealant drainage combined with an external fixator
- Authors:
- Ye, Hui
Lin, Shufeng
Zhu, Junfeng
Jiang, Lifeng - Other Names:
- Mayr. Johannes section editor.
- Abstract:
- Abstract: Objective: To determine the effects of an improved method of peri-pin membrane immobilization in tibial Gustilo type III fracture treated with vacuum sealant drainage (VSD) combined with an external fixator. Method: A biliary T tube of suitable size and type was cut into a certain long arm and cross arm which wrapping around a pin to improving traditional peri-pin VSD method. Eighty-six cases of Gustilo type III tibial fracture admitted from January 2016 to December 2019 were prospectively treated, of which 43 cases were treated using a traditional method of VSD (Traditional group) and 43 cases in which VSD treatment was enhanced (Improved group). The 2 groups were compared by some clinical indexes. Statistical software was then used for data analysis. P < .05 was considered statistically significant. Results: Compared with the Traditional group, the improved group significantly reduced granulation tissue growth time (day) (7.35 + 2.59 vs 11.14 + 2.54, P < .05), antibiotic use time (day) (6.67 + 2.39 vs 8.70 + 1.98, P < .05), operation time (min) (72.44 + 16.79 vs 85.47 + 17.44, P < .05) duration of hospital stay (day) (18.23 + 5.04 vs 21.53 + 4.79, P < .05), wound closure time (day) (9.23 + 2.69 vs 14.19 + 2.67, P < .05), air leakage around the fixed needle (3/43 vs 16/43, P < .05) and postoperative pain score ( P < .05). Meanwhile, the white blood cell, C-reactive protein, erythrocyte sedimentation rate of 1 week and 2 weeks post-operation were alsoAbstract: Objective: To determine the effects of an improved method of peri-pin membrane immobilization in tibial Gustilo type III fracture treated with vacuum sealant drainage (VSD) combined with an external fixator. Method: A biliary T tube of suitable size and type was cut into a certain long arm and cross arm which wrapping around a pin to improving traditional peri-pin VSD method. Eighty-six cases of Gustilo type III tibial fracture admitted from January 2016 to December 2019 were prospectively treated, of which 43 cases were treated using a traditional method of VSD (Traditional group) and 43 cases in which VSD treatment was enhanced (Improved group). The 2 groups were compared by some clinical indexes. Statistical software was then used for data analysis. P < .05 was considered statistically significant. Results: Compared with the Traditional group, the improved group significantly reduced granulation tissue growth time (day) (7.35 + 2.59 vs 11.14 + 2.54, P < .05), antibiotic use time (day) (6.67 + 2.39 vs 8.70 + 1.98, P < .05), operation time (min) (72.44 + 16.79 vs 85.47 + 17.44, P < .05) duration of hospital stay (day) (18.23 + 5.04 vs 21.53 + 4.79, P < .05), wound closure time (day) (9.23 + 2.69 vs 14.19 + 2.67, P < .05), air leakage around the fixed needle (3/43 vs 16/43, P < .05) and postoperative pain score ( P < .05). Meanwhile, the white blood cell, C-reactive protein, erythrocyte sedimentation rate of 1 week and 2 weeks post-operation were also reduced after adopting the improved method ( P < .05). The difference in infection around the fixation pin and pin loosening between the 2 groups was not significant. Conclusion: The biliary T tube was effctive in improving VSD combined with external fixation for the treatment of tibial Gustilo type III fractures. The materials are easy to obtain and straightforward to use and so is worthy of clinical promotion. … (more)
- Is Part Of:
- Medicine. Volume 99:Issue 43(2020)
- Journal:
- Medicine
- Issue:
- Volume 99:Issue 43(2020)
- Issue Display:
- Volume 99, Issue 43 (2020)
- Year:
- 2020
- Volume:
- 99
- Issue:
- 43
- Issue Sort Value:
- 2020-0099-0043-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-10-23
- Subjects:
- air leakage -- external fixation -- gustilo III type -- T-tube -- vacuum sealant drainage
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000022846 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15107.xml