Comparison of 3 Devices for 24-Hour Ambulatory Blood Pressure Monitoring in a Nonclinical Environment Through a Randomized Trial. (23rd July 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of 3 Devices for 24-Hour Ambulatory Blood Pressure Monitoring in a Nonclinical Environment Through a Randomized Trial. (23rd July 2020)
- Main Title:
- Comparison of 3 Devices for 24-Hour Ambulatory Blood Pressure Monitoring in a Nonclinical Environment Through a Randomized Trial
- Authors:
- Nwankwo, Tatiana
Coleman King, Sallyann M
Ostchega, Yechiam
Zhang, Guangyu
Loustalot, Fleetwood
Gillespie, Cathleen
Chang, Tiffany E
Begley, Elin B
George, Mary G
Shimbo, Daichi
Schwartz, Joseph E
Muntner, Paul
Kronish, Ian M
Hong, Yuling
Merritt, Robert - Abstract:
- Abstract: Background: The U.S. Preventive Services Task Force recommends the use of 24-hour ambulatory blood pressure monitoring (ABPM) as part of screening and diagnosis of hypertension. The optimal ABPM device for population-based surveys is unknown. Methods: We compared the proportion of valid blood pressure (BP) readings, mean awake and asleep BP readings, differences between awake ABPM readings and initial standardized BP readings, and sleep experience among three ABPM devices. We randomized a convenience sample of 365 adults to 1 of 3 ABPM devices: Welch Allyn Mobil-O-Graph (WA), Sun Tech Classic Oscar2 (STO) and Spacelabs 90227 (SL). Participants completed sleep quality questionnaires on the nights before and during ABPM testing. Results: The proportions of valid BP readings were not different among the 3 devices ( P > 0.45). Mean awake and asleep systolic BP were significantly higher for STO device (WA vs. STO vs. SL: 126.65, 138.09, 127.44 mm Hg; 114.34, 120.34, 113.13 mm Hg; P < 0.0001 for both). The difference between the initial average standardized mercury systolic BP readings and the ABPM mean awake systolic BP was larger for STO device (WA vs. STO. vs. SL: –5.26, –16.24, –5.36 mm Hg; P < 0.0001); diastolic BP mean differences were ~ –6 mm Hg for all 3 devices ( P = 0.6). Approximately 55% of participants reported that the devices interfered with sleep; however, there were no sleep differences across the devices ( P > 0.4 for all). Conclusion: Most of theAbstract: Background: The U.S. Preventive Services Task Force recommends the use of 24-hour ambulatory blood pressure monitoring (ABPM) as part of screening and diagnosis of hypertension. The optimal ABPM device for population-based surveys is unknown. Methods: We compared the proportion of valid blood pressure (BP) readings, mean awake and asleep BP readings, differences between awake ABPM readings and initial standardized BP readings, and sleep experience among three ABPM devices. We randomized a convenience sample of 365 adults to 1 of 3 ABPM devices: Welch Allyn Mobil-O-Graph (WA), Sun Tech Classic Oscar2 (STO) and Spacelabs 90227 (SL). Participants completed sleep quality questionnaires on the nights before and during ABPM testing. Results: The proportions of valid BP readings were not different among the 3 devices ( P > 0.45). Mean awake and asleep systolic BP were significantly higher for STO device (WA vs. STO vs. SL: 126.65, 138.09, 127.44 mm Hg; 114.34, 120.34, 113.13 mm Hg; P < 0.0001 for both). The difference between the initial average standardized mercury systolic BP readings and the ABPM mean awake systolic BP was larger for STO device (WA vs. STO. vs. SL: –5.26, –16.24, –5.36 mm Hg; P < 0.0001); diastolic BP mean differences were ~ –6 mm Hg for all 3 devices ( P = 0.6). Approximately 55% of participants reported that the devices interfered with sleep; however, there were no sleep differences across the devices ( P > 0.4 for all). Conclusion: Most of the participants met the threshold of 70% valid readings over 24 hours. Sleep disturbance was common but did not interfere with completion of measurement in most of the participants. … (more)
- Is Part Of:
- American journal of hypertension. Volume 33:Number 11(2020)
- Journal:
- American journal of hypertension
- Issue:
- Volume 33:Number 11(2020)
- Issue Display:
- Volume 33, Issue 11 (2020)
- Year:
- 2020
- Volume:
- 33
- Issue:
- 11
- Issue Sort Value:
- 2020-0033-0011-0000
- Page Start:
- 1021
- Page End:
- 1029
- Publication Date:
- 2020-07-23
- Subjects:
- 24-hour ABPM -- blood pressure -- blood pressure measurement -- BP -- hypertension -- National Health and Nutrition Examination Survey -- NHANES
Hypertension -- Periodicals
616.132005 - Journal URLs:
- http://ajh.oxfordjournals.org/ ↗
http://www.nature.com/ajh/index.html ↗
http://ukcatalogue.oup.com/ ↗
http://www.sciencedirect.com/science/journal/08957061 ↗ - DOI:
- 10.1093/ajh/hpaa117 ↗
- Languages:
- English
- ISSNs:
- 0895-7061
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0826.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15102.xml