Validation of a Metabolite Panel for a More Accurate Estimation of Glomerular Filtration Rate Using Quantitative LC-MS/MS. (1st March 2019)
- Record Type:
- Journal Article
- Title:
- Validation of a Metabolite Panel for a More Accurate Estimation of Glomerular Filtration Rate Using Quantitative LC-MS/MS. (1st March 2019)
- Main Title:
- Validation of a Metabolite Panel for a More Accurate Estimation of Glomerular Filtration Rate Using Quantitative LC-MS/MS
- Authors:
- Freed, Tiffany A
Coresh, Josef
Inker, Lesley A
Toal, Douglas R
Perichon, Regis
Chen, Jingsha
Goodman, Kelli D
Zhang, Qibo
Conner, Jessie K
Hauser, Deirdre M
Vroom, Kate E T
Oyaski, Maria L
Wulff, Jacob E
Eiríksdóttir, Gudný
Gudnason, Vilmundur
Torres, Vicente E
Ford, Lisa A
Levey, Andrew S - Abstract:
- Abstract: BACKGROUND: Clinical practice guidelines recommend estimation of glomerular filtration rate (eGFR) using validated equations based on serum creatinine (eGFRcr), cystatin C (eGFRcys), or both (eGFRcr-cys). However, when compared with the measured GFR (mGFR), only eGFRcr-cys meets recommended performance standards. Our goal was to develop a more accurate eGFR method using a panel of metabolites without creatinine, cystatin C, or demographic variables. METHODS: An ultra-performance liquid chromatography–tandem mass spectrometry assay for acetylthreonine, phenylacetylglutamine, pseudouridine, and tryptophan was developed, and a 20-day, multiinstrument analytical validation was conducted. The assay was tested in 2424 participants with mGFR data from 4 independent research studies. A new GFR equation (eGFRmet) was developed in a random subset (n = 1615) and evaluated in the remaining participants (n = 809). Performance was assessed as the frequency of large errors [estimates that differed from mGFR by at least 30% (1 − P30 ); goal <10%]. RESULTS: The assay had a mean imprecision (≤10% intraassay, ≤6.9% interassay), linearity over the quantitative range ( r 2 > 0.98), and analyte recovery (98.5%–113%). There was no carryover, no interferences observed, and analyte stability was established. In addition, 1 − P30 in the validation set for eGFRmet (10.0%) was more accurate than eGFRcr (13.1%) and eGFRcys (12.0%) but not eGFRcr-cys (8.7%). Combining metabolites, creatinine,Abstract: BACKGROUND: Clinical practice guidelines recommend estimation of glomerular filtration rate (eGFR) using validated equations based on serum creatinine (eGFRcr), cystatin C (eGFRcys), or both (eGFRcr-cys). However, when compared with the measured GFR (mGFR), only eGFRcr-cys meets recommended performance standards. Our goal was to develop a more accurate eGFR method using a panel of metabolites without creatinine, cystatin C, or demographic variables. METHODS: An ultra-performance liquid chromatography–tandem mass spectrometry assay for acetylthreonine, phenylacetylglutamine, pseudouridine, and tryptophan was developed, and a 20-day, multiinstrument analytical validation was conducted. The assay was tested in 2424 participants with mGFR data from 4 independent research studies. A new GFR equation (eGFRmet) was developed in a random subset (n = 1615) and evaluated in the remaining participants (n = 809). Performance was assessed as the frequency of large errors [estimates that differed from mGFR by at least 30% (1 − P30 ); goal <10%]. RESULTS: The assay had a mean imprecision (≤10% intraassay, ≤6.9% interassay), linearity over the quantitative range ( r 2 > 0.98), and analyte recovery (98.5%–113%). There was no carryover, no interferences observed, and analyte stability was established. In addition, 1 − P30 in the validation set for eGFRmet (10.0%) was more accurate than eGFRcr (13.1%) and eGFRcys (12.0%) but not eGFRcr-cys (8.7%). Combining metabolites, creatinine, cystatin C, and demographics led to the most accurate equation (7.0%). Neither equation had substantial variation among population subgroups. CONCLUSIONS: The new eGFRmet equation could serve as a confirmatory test for GFR estimation. … (more)
- Is Part Of:
- Clinical chemistry. Volume 65:Number 3(2019)
- Journal:
- Clinical chemistry
- Issue:
- Volume 65:Number 3(2019)
- Issue Display:
- Volume 65, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 65
- Issue:
- 3
- Issue Sort Value:
- 2019-0065-0003-0000
- Page Start:
- 406
- Page End:
- 418
- Publication Date:
- 2019-03-01
- Subjects:
- Clinical chemistry -- Periodicals
Pharmaceutical chemistry -- Periodicals
Biochemistry -- Periodicals
Biochimie -- Périodiques
Diagnostics biologiques -- Périodiques
Biochemistry
Clinical chemistry
Pharmaceutical chemistry
Biochemistry
Laboratory Techniques and Procedures
Klinische chemie
Periodicals
616.075605 - Journal URLs:
- http://www.oxfordjournals.org/ ↗
https://academic.oup.com/clinchem ↗
http://catalog.hathitrust.org/api/volumes/oclc/1554929.html ↗
http://www.clinchem.org/ ↗ - DOI:
- 10.1373/clinchem.2018.288092 ↗
- Languages:
- English
- ISSNs:
- 0009-9147
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15109.xml