Clinical outcomes of Watchman vs. Amplatzer occluders for left atrial appendage closure (WATCH at LAAC). Issue 6 (31st January 2020)
- Record Type:
- Journal Article
- Title:
- Clinical outcomes of Watchman vs. Amplatzer occluders for left atrial appendage closure (WATCH at LAAC). Issue 6 (31st January 2020)
- Main Title:
- Clinical outcomes of Watchman vs. Amplatzer occluders for left atrial appendage closure (WATCH at LAAC)
- Authors:
- Kleinecke, Caroline
Yu, Jiangtao
Neef, Philip
Buffle, Eric
de Marchi, Stefano
Fuerholz, Monika
Nietlispach, Fabian
Valgimigli, Marco
Streit, Samuel R
Fankhauser, Mate
Duenninger, Erich
Windecker, Stephan
Meier, Bernhard
Gloekler, Steffen - Abstract:
- Abstract: Aims: This study compares clinical outcomes of Watchman vs. Amplatzer devices for left atrial appendage closure (LAAC). Methods and results: Of two real-world registries, the Watchman registry Lichtenfels, Germany, and the Amplatzer registry Bern-Zurich, Switzerland, 303 and 333 consecutive patients, respectively, were included. After a 1:1 propensity score matching, 266 vs. 266 patients were compared by use of the predefined primary efficacy endpoint of stroke, systemic embolism and cardiovascular/unexplained death, the primary safety endpoint of major peri-procedural complications and major bleeding events at follow-up, and the combined hazard endpoint, a composite of all above-mentioned hazards. Mean age was 75.3 ± 7.8 (Watchman) vs. 75.1 ± 9.9 (Amplatzer) years, CHA2 DS2 -VASc score 4.5 ± 1.7 vs. 4.5 ± 1.5, and HAS-BLED score 3.2 ± 1.0 vs. 3.2 ± 1.0. At a mean follow-up of 2.4 ± 1.3 vs. 2.5 ± 1.5 years and 1.322 patient-years, the primary endpoints of efficacy [40/646, 6.2% [Watchman] vs. 43/676, 6.4% [Amplatzer]; hazard ratio (HR), 1.02; 95% confidence interval (CI), 0.66–1.58; P = 0.92] and safety (33/646, 5.1% vs. 30/676, 4.4%; HR, 0.57; 95% CI, 0.29–1.11; P = 0.10), as well as the combined hazard endpoint (69/646, 10.7% vs. 66/676, 9.8%; HR, 0.80; 95% CI, 0.55–1.12; P = 0.26) were similar for both groups. Conclusion: This study suggests comparable efficacy and safety of the Watchman and Amplatzer devices.
- Is Part Of:
- Europace. Volume 22:Issue 6(2020)
- Journal:
- Europace
- Issue:
- Volume 22:Issue 6(2020)
- Issue Display:
- Volume 22, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 6
- Issue Sort Value:
- 2020-0022-0006-0000
- Page Start:
- 916
- Page End:
- 923
- Publication Date:
- 2020-01-31
- Subjects:
- Atrial fibrillation -- Stroke prevention -- Left atrial appendage closure -- Watchman -- Amplatzer -- Anticoagulation
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa001 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15094.xml