CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT SKIN DOSES IN FINLAND. Issue 2 (14th December 2019)
- Record Type:
- Journal Article
- Title:
- CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT SKIN DOSES IN FINLAND. Issue 2 (14th December 2019)
- Main Title:
- CONTEMPORARY RADIATION DOSES IN INTERVENTIONAL CARDIOLOGY: A NATIONWIDE STUDY OF PATIENT SKIN DOSES IN FINLAND
- Authors:
- Järvinen, Jukka
Sierpowska, Joanna
Siiskonen, Teemu
Husso, Minna
Järvinen, Hannu
Kiviniemi, Tuomas
Rissanen, Tuomas T
Lindholm, Carita
Matikka, Hanna
Larjava, Heli R S
Mäkelä, Timo J
Strengell, Satu
Eskola, Markku
Parviainen, Teuvo
Hallinen, Elina
Pirinen, Markku
Kivelä, Antti
Teräs, Mika - Abstract:
- Abstract: In contemporary interventional cardiology, for typical elderly patients, the most severe radiation-related harm to patients can be considered to come from skin exposures. In this paper, maximum local skin doses in cardiological procedures are explored with Gafchromic film dosimetry. Film and reader calibrations and reading were performed at the Secondary Standards Dosimetry Laboratory of the Radiation and Nuclear Safety Authority (STUK), and data were gathered from seven hospitals in Finland. As alert levels for early transient erythema, 200 Gycm 2 kerma area product (KAP) and 2000 mGy air kerma levels for transcatheter aortic valve implantations (TAVI) procedures are proposed. The largest doses were measured in TAVI (4158.8 mGy) and percutaneous coronary interventions (PCI) (941.68 mGy). Accuracies of the GE DoseWatch and Siemens CareMonitor skin dose estimates were reasonable, but more results are needed to reliably assess and validate the tools' capabilities and reliabilities. Uncertainty of the Gafchromic dosimetry was estimated as 9.1% for a calibration with seven data points and 19.3% for a calibration with five data points.
- Is Part Of:
- Radiation protection dosimetry. Volume 188:Issue 2(2020)
- Journal:
- Radiation protection dosimetry
- Issue:
- Volume 188:Issue 2(2020)
- Issue Display:
- Volume 188, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 188
- Issue:
- 2
- Issue Sort Value:
- 2020-0188-0002-0000
- Page Start:
- 181
- Page End:
- 190
- Publication Date:
- 2019-12-14
- Subjects:
- Radiation dosimetry -- Periodicals
Radiation -- Safety measures -- Periodicals
363.1799 - Journal URLs:
- http://rpd.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/rpd/ncz273 ↗
- Languages:
- English
- ISSNs:
- 0144-8420
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.993000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15081.xml