CHARACTERISATION AND EVALUATION OF AL2O3:C-BASED OPTICALLY STIMULATED LUMINESCENT DOSEMETER SYSTEM FOR DIAGNOSTIC X-RAYS: PERSONAL AND IN VIVO DOSIMETRY. Issue 4 (25th October 2019)
- Record Type:
- Journal Article
- Title:
- CHARACTERISATION AND EVALUATION OF AL2O3:C-BASED OPTICALLY STIMULATED LUMINESCENT DOSEMETER SYSTEM FOR DIAGNOSTIC X-RAYS: PERSONAL AND IN VIVO DOSIMETRY. Issue 4 (25th October 2019)
- Main Title:
- CHARACTERISATION AND EVALUATION OF AL2O3:C-BASED OPTICALLY STIMULATED LUMINESCENT DOSEMETER SYSTEM FOR DIAGNOSTIC X-RAYS: PERSONAL AND IN VIVO DOSIMETRY
- Authors:
- Wong, J H D
Bakhsh, M
Cheah, Y Y
Jong, W L
Khor, J S
Ng, K H - Abstract:
- Abstract: This study characterises and evaluates an Al2 O3 :C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reader accuracy, reproducibility, batch homogeneity, energy dependence and signal stability, were explored. The suitability of the nanoDot™ dosemeters was evaluated by measuring the depth dose curve, in vivo dose measurement and image perturbation. The nanoDot™ dosemeters were observed to produce a linear dose with ±2.8% coefficient variation. Significant batch inhomogeneity (8.3%) was observed. A slight energy dependence (±6.1%) was observed between 60 and 140 kVp. The InLight® microStar reader demonstrated good accuracy and a reproducibility of ±2%. The depth dose curve measured using nanoDot™ dosemeters showed slightly lower responses than Monte Carlo simulation results. The total uncertainty for a single dose measurement using this system was 11%, but it could be reduced to 9.2% when energy dependence correction was applied.
- Is Part Of:
- Radiation protection dosimetry. Volume 187:Issue 4(2019)
- Journal:
- Radiation protection dosimetry
- Issue:
- Volume 187:Issue 4(2019)
- Issue Display:
- Volume 187, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 187
- Issue:
- 4
- Issue Sort Value:
- 2019-0187-0004-0000
- Page Start:
- 451
- Page End:
- 460
- Publication Date:
- 2019-10-25
- Subjects:
- Radiation dosimetry -- Periodicals
Radiation -- Safety measures -- Periodicals
363.1799 - Journal URLs:
- http://rpd.oxfordjournals.org ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/rpd/ncz186 ↗
- Languages:
- English
- ISSNs:
- 0144-8420
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.993000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15077.xml