Long-term follow-up of abandoned transvenous defibrillator leads: a nationwide cohort study. Issue 7 (23rd May 2020)
- Record Type:
- Journal Article
- Title:
- Long-term follow-up of abandoned transvenous defibrillator leads: a nationwide cohort study. Issue 7 (23rd May 2020)
- Main Title:
- Long-term follow-up of abandoned transvenous defibrillator leads: a nationwide cohort study
- Authors:
- Elgaard, Anders Fyhn
Johansen, Jens Brock
Nielsen, Jens Cosedis
Gerdes, Christian
Riahi, Sam
Philbert, Berit Thornvig
Haarbo, Jens
Melchior, Thomas Maria
Larsen, Jacob Moesgaard - Abstract:
- Abstract: Aims : Commonly, a dysfunctional defibrillator lead is abandoned and a new lead is implanted. Long-term follow-up data on abandoned leads are sparse. We aimed to investigate the incidence and reasons for extraction of abandoned defibrillator leads in a nationwide cohort and to describe extraction procedure-related complications. Methods and results : All abandoned transvenous defibrillator leads were identified in the Danish Pacemaker and ICD Register from 1991 to 2019. The event-free survival of abandoned defibrillator leads was studied, and medical records of patients with interventions on abandoned defibrillator leads were audited for procedure-related data. We identified 740 abandoned defibrillator leads. Meantime from implantation to abandonment was 7.2 ± 3.8 years with mean patient age at abandonment of 66.5 ± 13.7 years. During a mean follow-up after abandonment of 4.4 ± 3.1 years, 65 (8.8%) abandoned defibrillator leads were extracted. Most frequent reason for extraction was infection (pocket and systemic) in 41 (63%) patients. Procedural outcome after lead extraction was clinical success in 63 (97%) patients. Minor complications occurred in 3 (5%) patients, and major complications in 1 (2%) patient. No patient died from complication to the procedure during 30-day follow-up after extraction. Conclusion : More than 90% of abandoned defibrillator leads do not need to be extracted during long-term follow-up. The most common indication for extraction isAbstract: Aims : Commonly, a dysfunctional defibrillator lead is abandoned and a new lead is implanted. Long-term follow-up data on abandoned leads are sparse. We aimed to investigate the incidence and reasons for extraction of abandoned defibrillator leads in a nationwide cohort and to describe extraction procedure-related complications. Methods and results : All abandoned transvenous defibrillator leads were identified in the Danish Pacemaker and ICD Register from 1991 to 2019. The event-free survival of abandoned defibrillator leads was studied, and medical records of patients with interventions on abandoned defibrillator leads were audited for procedure-related data. We identified 740 abandoned defibrillator leads. Meantime from implantation to abandonment was 7.2 ± 3.8 years with mean patient age at abandonment of 66.5 ± 13.7 years. During a mean follow-up after abandonment of 4.4 ± 3.1 years, 65 (8.8%) abandoned defibrillator leads were extracted. Most frequent reason for extraction was infection (pocket and systemic) in 41 (63%) patients. Procedural outcome after lead extraction was clinical success in 63 (97%) patients. Minor complications occurred in 3 (5%) patients, and major complications in 1 (2%) patient. No patient died from complication to the procedure during 30-day follow-up after extraction. Conclusion : More than 90% of abandoned defibrillator leads do not need to be extracted during long-term follow-up. The most common indication for extraction is infection. Abandoned defibrillator leads can be extracted with high clinical success rate and low risk of major complications at high-volume centres. … (more)
- Is Part Of:
- Europace. Volume 22:Issue 7(2020)
- Journal:
- Europace
- Issue:
- Volume 22:Issue 7(2020)
- Issue Display:
- Volume 22, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 7
- Issue Sort Value:
- 2020-0022-0007-0000
- Page Start:
- 1097
- Page End:
- 1102
- Publication Date:
- 2020-05-23
- Subjects:
- Implantable cardioverter-defibrillator -- Defibrillator lead -- Abandonment -- Abandoned -- Extraction
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa086 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15075.xml