Compliance of Textile Vascular Prostheses Is a Fleeting Reality. (November 2020)
- Record Type:
- Journal Article
- Title:
- Compliance of Textile Vascular Prostheses Is a Fleeting Reality. (November 2020)
- Main Title:
- Compliance of Textile Vascular Prostheses Is a Fleeting Reality
- Authors:
- Lucereau, Benoit
Koffhi, Foued
Lejay, Anne
Georg, Yannick
Durand, Bernard
Thaveau, Fabien
Heim, Frédéric
Chakfe, Nabil - Abstract:
- Abstract : Objective: Compliance is considered to be a major property influencing the long term performances of synthetic vascular substitutes that could play a role in anastomotic false aneurysm and intimal hyperplasia stenosis onset. Over the last decades, manufacturers have tried to develop substitutes that mechanically mimic arterial properties and avoid a compliance mismatch at the anastomoses in particular. However, data are missing about how initial compliance properties could change with time. The goal of this study was to evaluate how the compliance of vascular grafts evolves under cyclic loading conditions in vitro . Methods: The compliance of three different models of commercially available textile polyethylene terephthalate (PET) grafts was evaluated. Tests were performed with and without their original coating. Compliance was assessed with a specific device dedicated to measure the deformations undergone by a graft under cyclic pressure loading conditions, using image analysis software. In each experiment, image analysis was performed under 60 and 140 mmHg pressure loading conditions at loading start (H0) and after three, six, and 24 h (H3, H6, H24) loading time. Average radial, longitudinal, and volumetric compliance was calculated from the obtained images. Results: Twenty-four samples were tested. Results demonstrate that all values decreased significantly within only a few hours. On average, the loss of compliance after 3 h of cyclic loading ranged on averageAbstract : Objective: Compliance is considered to be a major property influencing the long term performances of synthetic vascular substitutes that could play a role in anastomotic false aneurysm and intimal hyperplasia stenosis onset. Over the last decades, manufacturers have tried to develop substitutes that mechanically mimic arterial properties and avoid a compliance mismatch at the anastomoses in particular. However, data are missing about how initial compliance properties could change with time. The goal of this study was to evaluate how the compliance of vascular grafts evolves under cyclic loading conditions in vitro . Methods: The compliance of three different models of commercially available textile polyethylene terephthalate (PET) grafts was evaluated. Tests were performed with and without their original coating. Compliance was assessed with a specific device dedicated to measure the deformations undergone by a graft under cyclic pressure loading conditions, using image analysis software. In each experiment, image analysis was performed under 60 and 140 mmHg pressure loading conditions at loading start (H0) and after three, six, and 24 h (H3, H6, H24) loading time. Average radial, longitudinal, and volumetric compliance was calculated from the obtained images. Results: Twenty-four samples were tested. Results demonstrate that all values decreased significantly within only a few hours. On average, the loss of compliance after 3 h of cyclic loading ranged on average from 35% for longitudinal compliance to 39% for radial compliance and 37% ( p < .050) for volume compliance. After 24 h, the loss of radial, longitudinal and volume compliance was respectively 63 ± 3%, 60.5 ± 2% and 61 ± 7%. Conclusion: In this in vitro model, PET graft compliance has already decreased significantly within 3 h. The rapid loss of compliance identified in this experimental study helps explain the mismatch mentioned in clinical observations. … (more)
- Is Part Of:
- European journal of vascular and endovascular surgery. Volume 60:Number 5(2020)
- Journal:
- European journal of vascular and endovascular surgery
- Issue:
- Volume 60:Number 5(2020)
- Issue Display:
- Volume 60, Issue 5 (2020)
- Year:
- 2020
- Volume:
- 60
- Issue:
- 5
- Issue Sort Value:
- 2020-0060-0005-0000
- Page Start:
- 773
- Page End:
- 779
- Publication Date:
- 2020-11
- Subjects:
- Compliance -- Compliance evolution -- Compliance mismatch -- Vascular graft
Blood-vessels -- Endoscopic surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Vascular Surgical Procedures -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Vaisseaux sanguins -- Chirurgie -- Périodiques
Vaisseaux sanguins -- Chirurgie endoscopique -- Périodiques
Blood-vessels -- Endoscopic surgery
Blood-vessels -- Surgery
Endoscopy
Electronic journals
Periodicals
Electronic journals
617.413005 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=1078-5884;screen=info;ECOIP ↗
http://www.harcourt-international.com/journals/ejvs/ ↗
http://www.harcourt-international.com/journals/ejvx/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10785884 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10785884 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejvs.2020.07.016 ↗
- Languages:
- English
- ISSNs:
- 1078-5884
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.747280
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15070.xml